INSTALLER: Leave these instructions with consumer.
CONSUMER: Retain for future reference.
Important:READ THESE INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION
WARNINGS AND SAFETY CODES
DANGER:
IF YOU SMELL GAS:
1. Shut off the gas to the appliance.
2. Extinguish any open fl ame.
3. Open lid.
4. If odor continues, keep away from the
appliance and immediately call your
gas supplier or the fi re department.
CODE AND SUPPLY REQUIREMENTS: This appliance
must be installed in accordance with local codes and
ordinances, or, in the absence of local codes, with the
latest National Fuel Gas Code (ANSI Z223.1/NFPA
54), or Natural Gas and Propane Storage and Handling
Installation Code (CSA-B149.1).
This appliance and its dedicated manual shutoff valve
must be disconnected from the gas-supply piping
system when testing the syst
em at pressures in
excess of ½ psig (3.5 kPa).
This appliance must be isolated from the gassupply piping system by closing its dedicated
manual shutoff valve during any pressure testing
of the gas-supply system at pressures up to and
including ½ psig (3.5 kPa).
Proper operation of your appliance
WARNING:
1. Do not store or use gasoline or other
fl ammable vapors and liquids in the
vicinity of this or any other appliance.
2. An LP cylinder not connected for use
shall not be stored in the vicinity of this
or any other appliance.
WARNING:
Improper installation, adjustment, alteration,
service, or maintenance can cause injury or
property damage. For proper installation, refer
to the installation instructions. For assistance
or additional information, consult a qualifi ed
professional installer, service agency, or the
gas supplier.
All electrical outlets in the vicinity of the appliance
must be properly grounded in accordance with local
codes, or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70, or the
Canadian Electrical Code, CSA C22.1, whichever
is applicable.
Keep all electrical-supply cords and fuel-supply
hoses away from any heated surface.
requires prompt and periodic
maintenance. See the CARE &
CLEANING section for details.
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746 Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
REV 0 - 1412030930
Certifi ed to: ANSI Z21.58b-2012
CSA 1.6b-2012
09-41
1
L-C2-447
SÛRETÉ ET CODES D’AVERTISSEMENT
INSTALLATION INSTRUCTIONS ET MANUEL DU PROPRIÉTAIRE
DANS LE CONTRE- SINGLE SIDEBURNER
DANGER:
SI VOUS SENTEZ LE GAZ :
1. Coupez le gaz à l’appareil.
2. Éteignez-vous n’importe quelle fl amme nue.
3. Ouvrez le couvercle si équipé d’un four.
4. Si l’odeur continue, gardez loin de
l’appareil et appelez immédiatement
votre département de fournisseur ou de
feu de gaz.
CONDITIONS DE CODE ET D’APPROVISIONNEMENT:
Ce gril doit être installé selon des codes et des ordonnances
locaux, ou, en l’absence des codes locaux, avec l’un ou l’autre
le plus défunt Code national de gaz de carburant (norme ANSI
Z223.1/NFPA 54), et Stockage de gaz naturel et de propane et manipulation du code d’installation (CSA-B149.1).
Cet appareil et ses différents robinets d’isolement doivent être
démontés du gaz-fournissent le système siffl ant en examinant
le système aux pressions au-dessus du ½ psig (kPa 3.5).
Cet appareil doit être isolé dans gaz-fournissent le système
siffl ant par fermeture que ses différents robinets d’isolement
manuels pendant tous les essais sous pression du gazfournissent le système aux pressions jusques et y compris
le ½ psig (kPa 3.5).
• Ce gril est pour ultilisation à l’extérieur seulement. Si
l’appareil est entreposé à l’intérieur, enlever les bouteilles et
les laisser à l’extérieur.
• Ne pas ranger le gril immédiatement aprés l’avoir utilisé.
le laisser refroidir avant de le déplacer ou de la ranger. Le
non respect de cette mesure de sécurité pourrait entraîner un
incendie causant des dommages à la propriété, des blessures
ou la mort.
• Ne pas utiliser cet appareil sous une surface combustible.
• Ne pas utiliser cet appareil sous un auvent. Le non respect
de cette mesure de sécurité pourrait entraîner un incendie ou
des blessures.
• Dégagement minimal entre les parois latérales et l’arriére
de l’appareil et la construction combustible (45.7 cm à partir
des parois latérales et 45.7cm à partir de l’arriére).
• Le régulareur de pression de gaz prévu avec cet appareil
de cuisson à gaz pour l’extérieur doit être utilisé. Ce régulateur
est réglé pour une pression de sortie de 5 pouces de colonne
de l’eau pour le gaz naturel, et 10 pouces pour le propane.
• LE RÉGULATEUR INCLUS D’APPAREILS EST ÉVALUÉ
POUR LE MAXIMUM DE 1/2 (LIVRES PAR POUCE CARRÉ).
SI VOTRE OFFRE DE GAZ EST 1/2 PLUS GRAND QUE
(LIVRES PAR POUCE CARRÉ), UN RÉGULATEUR
ADDITIONNEL DOIT ÊTRE INSTALLÉ AVANT LE GRIL. VOIR
LA SECTION DE CONDITIONS D’OFFRE DE GAZ POUR
LA PRESSION APPROPRIÉE D’OFFRE DE GAZ.
AVERTISSEMENT:
1. Ne stockez pas ou n’employez pas
l’essence ou d’autres vapeurs et liquides
infl ammables à proximité de ceci ou
d’aucun autre appareil.
2. Un cylindre de propane non relié pour
l’usage ne sera pas stocké à proximité
de ceci ou d’aucun autre appareil.
AVERTISSEMENT:
L’installation inexacte, l’ajustement,
le changement, le service, ou l’entretien
peuvent causer des dommages ou des dégats
matériels. Référez-vous à ce manuel. Pour
l’aide ou l’information additionnelle, consultez
un installateur professionnel qualifi é, l’agence
de service, ou le fournisseur de gaz.
Toutes les sorties électriques à proximité du gril doivent être
correctement fondues selon des codes locaux, ou en l’absence
de local code, avec le code électrique national, ANSI/NFPA
70, ou le code électrique canadien, CSA C22.1, celui qui est
applicable.
Maintenez tout électrique-fournissent des cordes et carburantfournissent des tuyaux partis de n’importe quelle surface de
chauffage.
• Ne couvrez jamais la surface entière de cuisine ou de gril
de gauffreuses ou de casseroles. La surchauffe se produira et
les brûleurs ne seront pas très performants quand la chaleur
de combustion est emprisonnée au-dessous de la surface à
cuire.
• Ne pulvérisez jamais l’eau sur une unité chaude de gaz,
comme ceci peut endommager des composants de porcelaine
ou de fer de fonte.
• Une fuite de GPL peut causer une incendie ou une
explosion si enfl ammée entraînant des blessures corporelles
graves ou la mort.
• Communiquez avec le fournisseur de GPL pour les
réparations ou pour disposer de qules bouteille ou du GPL
non utilisé.
Certifi é à la norme: ANSI Z21.58b-2012
CSA 1.6b-2012
INSTALLATEUR : Laissez ces instructions avec le consommateur.
CONSOMMATEUR : Maintenez pour la future référence.
REV 0 - 1412030930
2
L-C2-447
CONTENTS
1 WARNINGS AND SAFETY CODES
4 SINGLE SIDEBURNER PARTS LIST
5 COUNTERTOP OVERHANG
5 MODEL SPECIFICATIONS
6 COMBUSTIBLE ENCLOSURE CUT-OUT
6 SUBSTRATE
7 SINGLE SIDEBURNER DIMENSIONS TABLE
7 SIDEBURNER WIRING DIAGRAM
8 ELECTRICAL CONNECTIONS
8 MAINTENANCE AND SAFETY INFORMATION
9 INSTALLATION REQUIREMENTS
10 ENSURE PROPER COMBUSTION AIR AND COOLING AIRFLOW
10 GAS-SUPPLY PLUMBING REQUIREMENTS
11 NATURAL GAS INSTALLS
11 PROPANE GAS INSTALLS (HOUSEHOLD & CYLINDER)
11 WHEN A PROPANE CYLINDER IS USED
11 ENCLOSURE REQUIREMENTS
12 COUNTER PREPARATION
12 CONNECT THE GAS SUPPLY
12 INSTALLATION
13 CONNECT TO A POWER SOURCE
14 POWER SUPPLY (MULTIPLE ACCESSORY UNITS)
15 SLIDE UNIT INTO ENCLOSURE
15 POSITION THE BURNER CAP
15 ELECTRICAL SAFETY
16 CONVERTING THE GAS TYPE
17 AIR SHUTTER ADJUSTMENT
19 SAFE USE & MAINTENANCE OF PROPANE GAS CYLINDERS
21 LIGHTING (IGNITION) INSTRUCTIONS
21 SHUTTING OFF THE UNIT
22 CARE & CLEANING
23 CHECKING AND CONVERTING THE REGULATOR
23 CHECKING AND CONVERTING GAS TYPE
24 CONTROL PANEL REMOVAL
25 TROUBLESHOOTING
26 WARRANTY
REV 0 - 1412030930
3
L-C2-447
SINGLE SIDEBURNER PARTS LIST
Item DescriptionPart No.Qty.
Single sideburner cover3279-071
1.
Porcelain cast iron cooking grid35501
2.
Stainless steel cooking grid3550-S1
or
Burner assembly (w/ burner pipe)3279-321
3.
Control panel3279-071
4.
Valve manifold assembly3279-221
5.
Burner igniter3199-441
6.
Control knob30161
7.
Convertible regulatorPR-41
8.
Wire harness assembly
9.
Wire harness extension
10.
Power supply w/ connector *
11.
Flex connector w/ fi ttings
12.
‡
Not shown
Optional / purchased separately
*
‡
‡
‡
‡
3279-241
24182-551
24177-121
30311
1
3
2
3
5
4
7
REV 0 - 1412030930
8
6
4
L-C2-447
MODEL SPECIFICATIONS
MODEL SPECIFICATIONS TABLE
Table 1
Main burner
N/P orifi ce drill size
Input electrical requirements
#51 / #58
120VAC / 0.6A / 60 Hz
Non-combustible
enclosures
Combustible
enclosures
A Countertop to unit bottom cut-out12"12"
B Side to side cut-out11-
1
/2"12"
C Front to back cut-out†14"14-1/2"
D Control panel width cut-out‡12-5/8"12-5/8"
▲
The increased dimensions for combustible enclosures allow for a required air gap along
the sides and rear of the unit. See the COMBUSTIBLE ENCLOSURE CUT-OUT section
on the next page for details.
†
Includes any substrate at front wall of enclosure (in the area the rear of the control panel
is to sit fl ush against). See SUBSTRATE section on next page.
‡
Only applicable for enclosures that have countertops with an overhang (see illustration
and section below).
TOP VIEW
TOP VIEW
B
ENCLOSURE
CUT-OUT
(Countertop)
(Countertop)
X
DIMENSIONS
Control
panel
C
Lower support
(Control
Countertop
overhang
panel)
Clearance
D
1
/4"
(Overhang)
Y
FRONT VIEW
▲
▲
X= D-B÷2
Y= Total
Countertop
Overhang
Check
clearance for
control panel
removal
SIDE VIEW
A
See next page
for substrate
considerations
Countertop
overhang
Fig. 5-1
Control
panel
Countertop
overhang
COUNTERTOP OVERHANG
The control panel is designed to sit fl ush against the enclosure front wall. If the enclosure countertop extends beyond the front wall,
creating a countertop overhang, it must be cut fl ush with the front wall for the width of the control panel or a gap will be created exposing
the forward portions of the left and right side fi re walls of the unit. See illustrations above.
Important:FOR YOUR SAFETY, you must provide openings in the island enclosure for drainage, replacement air, and cross-
ventilation of any storage area exposed to possible leakage from gas connections, the unit, or propane tanks. See the
ENCLOSURE REQUIREMENTS section for details.
REV 0 - 1412030930
5
L-C2-447
MODEL SPECIFICATIONS (cont.)
COMBUSTIBLE ENCLOSURE CUT-OUT
This unit may be installed into combustible framing (wood, for instance) provided there is a minimum of a
1
/2" airspace between ALL sides of the unit and any combustible material.
Countertop
1
/2" min.
air gap to all
combustible
material
TOP VIEW
1
/2"
AIR GAP
(Sideburner)
Stainless
steel
hanger
Edge of
counter
cut-out
FRONT VIEW
(Sideburner)
1
/2"
AIR GAP
Maintain air gap all the way down
Stainless
steel
hanger
CountertopCountertop
(sides and rear) below countertop
Fig. 6-1
SUBSTRATE
When adding any substrate to the enclosure front wall (including tiles, stone, etc.), consider the following:
Substrate Behind Control Panel
Substrate Alongside Control Panel
Substrate + countertop "front to back" cutout
must equate to Dim. C (see previous page)
when the substrate sits fl ush behind the
control panel.
TOP VIEWTOP VIEW
(Countertop)
Substrate
(includes tiles,
Sideburner
liner
Flush
(Control panel)
Fig. 6-2Fig. 6-3
etc. at front of
C
1
/4"
Clearance
enclosure)
Countertop
overhang
(if applicable)
Any additional substrate alongside the control panel
does not need to be considered in Dim. C (see previous
page), however a 1/4" clearance on each side (same as
overhang) and below is required.
(Countertop)
Substrate
Sideburner
liner
Flush
(Control panel)
(includes tiles,
etc. at front of
C
1
/4"
Clearance
enclosure)
Countertop
overhang
(if applicable)
REV 0 - 1412030930
6
L-C2-447
Model
MODEL SPECIFICATIONS (cont.)
SINGLE SIDEBURNER DIMENSIONS TABLE
HeightWidthDepth
(Top to bottom)(Left to right)(Front to back)
Top of hanger to
bottom of unit
(E)
Hanger to hanger
(F)
Control panel
width
(G)
Maximum depth
(H)
3279
Burner igniter
12"15 1/2"12 1/8"20"
F
G
Fig. 7-1
SIDEBURNER WIRING DIAGRAM
H
E
REV 0 - 1412030930
Wire harness
assembly
Burner
manifold
Ground wire
Wire harness
extension
Note: In addition, a wire diagram for this unit can also be found affi xed to
the inside of the control panel.
7
L-C2-447
MAINTENANCE AND SAFETY INFORMATION
1. The sideburner and surrounding area MUST
remain clear of fl ammable substances such as
gasoline, yard debris, wood, etc.
2. The airfl ow through the vent space located below
the control panel must remain unobstructed.
3. When using propane gas:
and insect nests. A clogged tube can lead to a
fi re beneath the unit. A proper fl ame pattern will
ensure safe operation and optimal performance.
Adjust the air shutter as needed (see AIR
SHUTTER ADJUSTMENT).
5. The in-line gas valve or gas cylinder valve must
always be shut OFF when the unit is not in use.
a. The required ventilation openings in the
enclosure must be clear of debris.
6. Do not operate the burner with the cover in
place.
b. The propane cylinder, regulator, and rubber
hose must be in a location not subject to
temperature above 125° F (51° C).
7. Whenever reconnecting any wires, apply a
small amount of dielectric grease to the male
connector, then make the connection.
4. The fl ames on the burner burn evenly along the
burner cap with a steady fl ame (mostly blue). If
burner fl ames are not normal, check and clean
the orifi ce and burner/venturi tube for insects
WARNING: NEVER cover more than 75% of the cooking surface with griddles or pans. Overheating will occur, and
burners will not perform properly when combustion heat is trapped below the cooking surface.
CAUTION: NEVER spray water on a hot gas unit.
The unit serial identifi cation number and rating label are located on the inside of the
control panel. The unit must be completely cool before opening.
ELECTRICAL CONNECTIONS
This unit requires 120VAC power to operate.
Plug the power supply cord into a properly wired and inspected GFCI electrical
receptacle (15 AMP minimum). Use a heavy-duty grounded extension cord if necessary.
WARNING
Electrical Grounding Instructions
For your protection against shock hazard, this outdoor-cooking gas-appliance is equipped with a three-pronged
(grounding) electrical connector. This appliance should be connected to a properly grounded three-prong receptacle
using a grounding extension cord rated for outdoor use. Do not cut or remove the grounding prong from the connector.
REV 0 - 1412030930
8
L-C2-447
Loading...
+ 18 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.