WARNINGS AND SAFETY CODES
DANGER:
1. Shut off the gas to the appliance.
2. Extinguish any open fl ame.
3. Open lid.
4. If odor continues, keep away from the appliance and immediately call your gas supplier or the fi re department.
CODE AND SUPPLY REQUIREMENTS: This appliance must be installed in accordance with local codes and ordinances, or, in the absence of local codes, with the latest National Fuel Gas Code (ANSI Z223.1/NFPA
54), or Natural Gas and Propane Storage and Handling Installation Code (CSA-B149.1).
This appliance and its dedicated manual shutoff valve must be disconnected from the gas-supply piping
system when testing the syst
em at pressures in
excess of ½ psig (3.5 kPa).
This appliance must be isolated from the gas­supply piping system by closing its dedicated manual shutoff valve during any pressure testing of the gas-supply system at pressures up to and including ½ psig (3.5 kPa).
Proper operation of your appliance
WARNING:
1. Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
2. An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
WARNING:
Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. For proper installation, refer to the installation instructions. For assistance or additional information, consult a qualifi ed professional installer, service agency, or the
gas supplier.
All electrical outlets in the vicinity of the appliance must be properly grounded in accordance with local codes, or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, whichever
is applicable. Keep all electrical-supply cords and fuel-supply
hoses away from any heated surface.
requires prompt and periodic maintenance. See the CARE & CLEANING section for details.
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746 Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
REV 0 - 1412030930
Certifi ed to: ANSI Z21.58b-2012 CSA 1.6b-2012
09-41
1
L-C2-447
SÛRETÉ ET CODES D’AVERTISSEMENT
INSTALLATION INSTRUCTIONS ET MANUEL DU PROPRIÉTAIRE
DANS LE CONTRE- SINGLE SIDEBURNER
DANGER:
SI VOUS SENTEZ LE GAZ :
1. Coupez le gaz à l’appareil.
2. Éteignez-vous n’importe quelle fl amme nue.
3. Ouvrez le couvercle si équipé d’un four.
4. Si l’odeur continue, gardez loin de l’appareil et appelez immédiatement votre département de fournisseur ou de feu de gaz.
CONDITIONS DE CODE ET D’APPROVISIONNEMENT:
Ce gril doit être installé selon des codes et des ordonnances locaux, ou, en l’absence des codes locaux, avec l’un ou l’autre le plus défunt Code national de gaz de carburant (norme ANSI Z223.1/NFPA 54), et Stockage de gaz naturel et de propane et manipulation du code d’installation (CSA-B149.1).
Cet appareil et ses différents robinets d’isolement doivent être démontés du gaz-fournissent le système siffl ant en examinant le système aux pressions au-dessus du ½ psig (kPa 3.5).
Cet appareil doit être isolé dans gaz-fournissent le système siffl ant par fermeture que ses différents robinets d’isolement manuels pendant tous les essais sous pression du gaz­fournissent le système aux pressions jusques et y compris le ½ psig (kPa 3.5).
• Ce gril est pour ultilisation à l’extérieur seulement. Si l’appareil est entreposé à l’intérieur, enlever les bouteilles et les laisser à l’extérieur.
• Ne pas ranger le gril immédiatement aprés l’avoir utilisé. le laisser refroidir avant de le déplacer ou de la ranger. Le non respect de cette mesure de sécurité pourrait entraîner un incendie causant des dommages à la propriété, des blessures ou la mort.
Ne pas utiliser cet appareil sous une surface combustible.
Ne pas utiliser cet appareil sous un auvent. Le non respect de cette mesure de sécurité pourrait entraîner un incendie ou des blessures.
Dégagement minimal entre les parois latérales et l’arriére de l’appareil et la construction combustible (45.7 cm à partir des parois latérales et 45.7cm à partir de l’arriére).
• Le régulareur de pression de gaz prévu avec cet appareil de cuisson à gaz pour l’extérieur doit être utilisé. Ce régulateur est réglé pour une pression de sortie de 5 pouces de colonne de l’eau pour le gaz naturel, et 10 pouces pour le propane.
LE RÉGULATEUR INCLUS D’APPAREILS EST ÉVALUÉ POUR LE MAXIMUM DE 1/2 (LIVRES PAR POUCE CARRÉ). SI VOTRE OFFRE DE GAZ EST 1/2 PLUS GRAND QUE (LIVRES PAR POUCE CARRÉ), UN RÉGULATEUR ADDITIONNEL DOIT ÊTRE INSTALLÉ AVANT LE GRIL. VOIR LA SECTION DE CONDITIONS D’OFFRE DE GAZ POUR LA PRESSION APPROPRIÉE D’OFFRE DE GAZ.
AVERTISSEMENT:
1. Ne stockez pas ou n’employez pas l’essence ou d’autres vapeurs et liquides infl ammables à proximité de ceci ou d’aucun autre appareil.
2. Un cylindre de propane non relié pour l’usage ne sera pas stocké à proximité de ceci ou d’aucun autre appareil.
AVERTISSEMENT:
L’installation inexacte, l’ajustement, le changement, le service, ou l’entretien peuvent causer des dommages ou des dégats matériels. Référez-vous à ce manuel. Pour l’aide ou l’information additionnelle, consultez un installateur professionnel qualifi é, l’agence
de service, ou le fournisseur de gaz.
Toutes les sorties électriques à proximité du gril doivent être correctement fondues selon des codes locaux, ou en l’absence de local code, avec le code électrique national, ANSI/NFPA 70, ou le code électrique canadien, CSA C22.1, celui qui est applicable.
Maintenez tout électrique-fournissent des cordes et carburant­fournissent des tuyaux partis de n’importe quelle surface de chauffage.
• Ne couvrez jamais la surface entière de cuisine ou de gril de gauffreuses ou de casseroles. La surchauffe se produira et les brûleurs ne seront pas très performants quand la chaleur de combustion est emprisonnée au-dessous de la surface à cuire.
• Ne pulvérisez jamais l’eau sur une unité chaude de gaz, comme ceci peut endommager des composants de porcelaine ou de fer de fonte.
• Une fuite de GPL peut causer une incendie ou une explosion si enfl ammée entraînant des blessures corporelles graves ou la mort.
• Communiquez avec le fournisseur de GPL pour les réparations ou pour disposer de qules bouteille ou du GPL non utilisé.
Certifi é à la norme: ANSI Z21.58b-2012 CSA 1.6b-2012
INSTALLATEUR : Laissez ces instructions avec le consommateur.
CONSOMMATEUR : Maintenez pour la future référence.
REV 0 - 1412030930
2
L-C2-447
CONTENTS
1 WARNINGS AND SAFETY CODES 4 SINGLE SIDEBURNER PARTS LIST 5 COUNTERTOP OVERHANG 5 MODEL SPECIFICATIONS 6 COMBUSTIBLE ENCLOSURE CUT-OUT 6 SUBSTRATE 7 SINGLE SIDEBURNER DIMENSIONS TABLE 7 SIDEBURNER WIRING DIAGRAM 8 ELECTRICAL CONNECTIONS 8 MAINTENANCE AND SAFETY INFORMATION 9 INSTALLATION REQUIREMENTS 10 ENSURE PROPER COMBUSTION AIR AND COOLING AIRFLOW 10 GAS-SUPPLY PLUMBING REQUIREMENTS 11 NATURAL GAS INSTALLS 11 PROPANE GAS INSTALLS (HOUSEHOLD & CYLINDER) 11 WHEN A PROPANE CYLINDER IS USED 11 ENCLOSURE REQUIREMENTS 12 COUNTER PREPARATION 12 CONNECT THE GAS SUPPLY 12 INSTALLATION 13 CONNECT TO A POWER SOURCE 14 POWER SUPPLY (MULTIPLE ACCESSORY UNITS) 15 SLIDE UNIT INTO ENCLOSURE 15 POSITION THE BURNER CAP 15 ELECTRICAL SAFETY 16 CONVERTING THE GAS TYPE 17 AIR SHUTTER ADJUSTMENT 19 SAFE USE & MAINTENANCE OF PROPANE GAS CYLINDERS 21 LIGHTING (IGNITION) INSTRUCTIONS 21 SHUTTING OFF THE UNIT 22 CARE & CLEANING 23 CHECKING AND CONVERTING THE REGULATOR 23 CHECKING AND CONVERTING GAS TYPE 24 CONTROL PANEL REMOVAL 25 TROUBLESHOOTING 26 WARRANTY
REV 0 - 1412030930
3
L-C2-447
SINGLE SIDEBURNER PARTS LIST
Item Description Part No. Qty.
Single sideburner cover 3279-07 1
1.
Porcelain cast iron cooking grid 3550 1
2.
Stainless steel cooking grid 3550-S 1
or
Burner assembly (w/ burner pipe) 3279-32 1
3.
Control panel 3279-07 1
4.
Valve manifold assembly 3279-22 1
5.
Burner igniter 3199-44 1
6.
Control knob 3016 1
7.
Convertible regulator PR-4 1
8.
Wire harness assembly
9.
Wire harness extension
10.
Power supply w/ connector *
11.
Flex connector w/ fi ttings
12.
Not shown
Optional / purchased separately
*
3279-24 1
24182-55 1
24177-12 1
3031 1
1
3
2
3
5
4
7
REV 0 - 1412030930
8
6
4
L-C2-447
MODEL SPECIFICATIONS
MODEL SPECIFICATIONS TABLE
Table 1
Main burner N/P orifi ce drill size
Input electrical requirements
#51 / #58
120VAC / 0.6A / 60 Hz
Non-combustible
enclosures
Combustible
enclosures A Countertop to unit bottom cut-out 12" 12" B Side to side cut-out 11-
1
/2" 12"
C Front to back cut-out 14" 14-1/2" D Control panel width cut-out 12-5/8" 12-5/8"
The increased dimensions for combustible enclosures allow for a required air gap along the sides and rear of the unit. See the COMBUSTIBLE ENCLOSURE CUT-OUT section on the next page for details.
Includes any substrate at front wall of enclosure (in the area the rear of the control panel
is to sit fl ush against). See SUBSTRATE section on next page.
Only applicable for enclosures that have countertops with an overhang (see illustration and section below).
TOP VIEW
TOP VIEW
B
ENCLOSURE
CUT-OUT
(Countertop)
(Countertop)
X
DIMENSIONS
Control
panel
C
Lower support
(Control
Countertop
overhang
panel)
Clearance
D
1
/4"
(Overhang)
Y
FRONT VIEW
X= D-B÷2 Y= Total Countertop Overhang
Check clearance for control panel
removal
SIDE VIEW
A
See next page
for substrate
considerations
Countertop
overhang
Fig. 5-1
Control
panel
Countertop
overhang
COUNTERTOP OVERHANG
The control panel is designed to sit fl ush against the enclosure front wall. If the enclosure countertop extends beyond the front wall, creating a countertop overhang, it must be cut fl ush with the front wall for the width of the control panel or a gap will be created exposing the forward portions of the left and right side fi re walls of the unit. See illustrations above.
Important: FOR YOUR SAFETY, you must provide openings in the island enclosure for drainage, replacement air, and cross-
ventilation of any storage area exposed to possible leakage from gas connections, the unit, or propane tanks. See the ENCLOSURE REQUIREMENTS section for details.
REV 0 - 1412030930
5
L-C2-447
MODEL SPECIFICATIONS (cont.)
COMBUSTIBLE ENCLOSURE CUT-OUT
This unit may be installed into combustible framing (wood, for instance) provided there is a minimum of a
1
/2" airspace between ALL sides of the unit and any combustible material.
Countertop
1
/2" min.
air gap to all
combustible
material
TOP VIEW
1
/2"
AIR GAP
(Sideburner)
Stainless
steel
hanger
Edge of counter
cut-out
FRONT VIEW
(Sideburner)
1
/2"
AIR GAP
Maintain air gap all the way down
Stainless
steel
hanger
CountertopCountertop
(sides and rear) below countertop
Fig. 6-1
SUBSTRATE
When adding any substrate to the enclosure front wall (including tiles, stone, etc.), consider the following:
Substrate Behind Control Panel
Substrate Alongside Control Panel
Substrate + countertop "front to back" cutout must equate to Dim. C (see previous page) when the substrate sits fl ush behind the control panel.
TOP VIEW TOP VIEW
(Countertop)
Substrate
(includes tiles,
Sideburner
liner
Flush
(Control panel)
Fig. 6-2 Fig. 6-3
etc. at front of
C
1
/4"
Clearance
enclosure)
Countertop
overhang
(if applicable)
Any additional substrate alongside the control panel does not need to be considered in Dim. C (see previous page), however a 1/4" clearance on each side (same as overhang) and below is required.
(Countertop)
Substrate
Sideburner
liner
Flush
(Control panel)
(includes tiles,
etc. at front of
C
1
/4"
Clearance
enclosure)
Countertop
overhang
(if applicable)
REV 0 - 1412030930
6
L-C2-447
Model
MODEL SPECIFICATIONS (cont.)
SINGLE SIDEBURNER DIMENSIONS TABLE
Height Width Depth
(Top to bottom) (Left to right) (Front to back)
Top of hanger to
bottom of unit
(E)
Hanger to hanger
(F)
Control panel
width
(G)
Maximum depth
(H)
3279
Burner igniter
12" 15 1/2" 12 1/8" 20"
F
G
Fig. 7-1
SIDEBURNER WIRING DIAGRAM
H
E
REV 0 - 1412030930
Wire harness
assembly
Burner
manifold
Ground wire
Wire harness
extension
Note: In addition, a wire diagram for this unit can also be found affi xed to
the inside of the control panel.
7
L-C2-447
MAINTENANCE AND SAFETY INFORMATION
1. The sideburner and surrounding area MUST
remain clear of fl ammable substances such as gasoline, yard debris, wood, etc.
2. The airfl ow through the vent space located below
the control panel must remain unobstructed.
3. When using propane gas:
and insect nests. A clogged tube can lead to a fi re beneath the unit. A proper fl ame pattern will ensure safe operation and optimal performance. Adjust the air shutter as needed (see AIR SHUTTER ADJUSTMENT).
5. The in-line gas valve or gas cylinder valve must
always be shut OFF when the unit is not in use.
a. The required ventilation openings in the
enclosure must be clear of debris.
6. Do not operate the burner with the cover in place.
b. The propane cylinder, regulator, and rubber
hose must be in a location not subject to temperature above 125° F (51° C).
7. Whenever reconnecting any wires, apply a
small amount of dielectric grease to the male connector, then make the connection.
4. The fl ames on the burner burn evenly along the
burner cap with a steady fl ame (mostly blue). If burner fl ames are not normal, check and clean the orifi ce and burner/venturi tube for insects
WARNING: NEVER cover more than 75% of the cooking surface with griddles or pans. Overheating will occur, and
burners will not perform properly when combustion heat is trapped below the cooking surface.
CAUTION: NEVER spray water on a hot gas unit.
The unit serial identifi cation number and rating label are located on the inside of the
control panel. The unit must be completely cool before opening.
ELECTRICAL CONNECTIONS
This unit requires 120VAC power to operate.
Plug the power supply cord into a properly wired and inspected GFCI electrical
receptacle (15 AMP minimum). Use a heavy-duty grounded extension cord if necessary.
WARNING
Electrical Grounding Instructions For your protection against shock hazard, this outdoor-cooking gas-appliance is equipped with a three-pronged (grounding) electrical connector. This appliance should be connected to a properly grounded three-prong receptacle using a grounding extension cord rated for outdoor use. Do not cut or remove the grounding prong from the connector.
REV 0 - 1412030930