Fire Magic 32791 Installation

SINGLE SIDEBURNER
Natural Gas or Propane Gas
Model # 3279-(1,2)(P)
INSTALLER: Please leave these instructions with the consumer. CONSUMER: Retain for future reference.
DANGER
IF YOU SMELL GAS:
1. Shut off the gas to the appliance.
2. Extinguish any open fl ame.
3. Open lid if equipped.
4. If odor continues, keep away from the appliance
and immediately call your gas supplier or fi re department.
1. Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity of this or any other appliance.
2. A propane cylinder not connected for use
shall not be stored in the vicinity of this or any other appliance.
WARNING
WARNING
CODE AND SUPPLY REQUIREMENTS: This unit
must be installed in accordance with local codes and ordinances, or, in the absence of local codes, with either the latest National Fuel Gas Code (ANSI Z223.1/NFPA
54), CAN/CGA-B149.1 (Natural Gas Installation Code), or CAN/CGA-B149.2 (Propane Installation Code).
This appliance and its individual shutoff valves must be disconnected from the gas supply piping system when testing the system at pressures in excess of ½ psig (3.5
kPa). This appliance must be isolated from the gas supply
piping system by closing its individual manual shutoff valves during any pressure testing of the gas supply system at pressures up to and including ½ psig (3.5 kPa).
Certifi ed to: ANSI Z21.58-2007 CSA 1.6-2007
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult qualifi ed, professional installer, service agency,
or the gas supplier.
All electrical outlets in the vicinity of the unit must be properly grounded in accordance with local codes or, in the absence of local codes, with the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, which ever is applicable.
Keep all electrical supply cords and fuel supply hoses away from any heated surface.
09-41
REV 6 - 0906231541
Robert H. Peterson Co. • 14724 East Proctor Avenue, • City of Industry, CA 91746
1
No. L-C2-18909
SIMPLE SIDEBURNER
Gaz naturel ou gaz de propane
Numéros de type 3279-(1,2)(P)
INSTALLATEUR : Veuillez laisser ces instructions avec le consommateur. CONSOMMATEUR : Maintenez pour la future référence.
INSTALLATION ET CONSIGNES D'UTILISATION
DANGER
SI VOUS SENTEZ LE GAZ:
1. Coupez le gaz à l'appareil.
2. Éteignez-vous n'importe quelle fl amme nue.
3. Ouvrez le couvercle si équipé.
4. Si l'odeur continue, gardez à partir de l'appareil
et appelez immédiatement votre fournisseur ou corps de sapeurs-pompiers de gaz.
CODE AND SUPPLY REQUIREMENTS: This unit must be installed in accordance with local codes and ordinances, or, in the absence of local codes, with either the latest National Fuel Gas Code (ANSI Z223.1/NFPA
54), CAN/CGA-B149.1 (Natural Gas Installation Code), or CAN/CGA-B149.2 (Propane Installation Code).
This appliance and its individual shutoff valves must be disconnected from the gas supply piping system when testing the system at pressures in excess of ½ psig (3.5
kPa). This appliance must be isolated from the gas supply
piping system by closing its individual manual shutoff valves during any pressure testing of the gas supply system at pressures up to and including ½ psig (3.5 kPa).
Gardez tous les cordes d'alimentation électrique et tuyaux de fourniture en combustible à partir de n'importe quelle surface heated.
Robert H. Peterson Co. • 14724 East Proctor Avenue, • City of Industry, CA 91746
AVERTISSEMENT
1. Ne stockez pas ou n'employez l'essence ou
d'autres vapeurs et liquides infl ammables à proximité de ceci ou d'aucun autre appareil.
2. Un cylindre de propane non relié pour l'usage
ne sera stocké à proximité de ceci ou d'aucun autre appareil.
AVERTISSEMENT
L'installation, l'ajustement, le changement, le service ou l'entretien inexact peuvent causer des dommages ou des dégats matériels. Référez-vous à ce manuel. Pour l'aide ou les informations supplémentaires consultez l'installateur qualifi é et professionnel, l'agence
de service, ou le fournisseur de gaz.
Toutes les sorties électriques à proximité de l'unité doivent être correctement fondues selon des codes locaux ou, en l'absence des codes locaux, avec le code électrique national, ANSI/NFPA 70, ou le code électr ique canadien, CSA C22.1, qui s'applique jamais.
Certifi é à la norme: ANSI Z21.58-2007 CSA 1.6-2007
09-41
REV 6 - 0906231541
2
L-C2-18909
SINGLE SIDEBURNER PARTS LIST
Item Description (Qty.) No.
1. Cover, single burner 2a. Porcelain cast iron grid or 2b. Stainless steel grid
3. Assy, single brnr (w/burner pipe)
4. Assy, control panel stainless steel
5. Assy, manifold single burner
6. Knob, Fire Magic
7. Regulator
8. Ignitor Assy
2a
1
2b
3
5
4
6
PRODUCT DATA TABLE
Specifi cation Value Counter Opening Height* 12" (30.5 cm) Counter Opening Width* 11 1/2" Counter Opening Depth* 14"
8
7
REV 6 - 0906231541
BTU per burner Natural Gas Orifi ce Propane Gas Orifi ce
Table 1 - Product data table
Single Side Burner
15,000 BTU #50 #58
3
No. L-C2-18909
PLANNING FOR INSTALLATION OF YOUR SINGLE SIDE BURNER
WHERE TO INSTALL YOUR
SINGLE SIDEBURNER
FOR OUTDOOR USE ONLY.
Do not install this unit under unprotected fl ammable surfaces. Do not install or use this appliance inside a building, garage, or any other covered area. It must not be used in or on recreational vehicles or boats.
This is a built-in type unit designed to fi t into open-front enclosures. The control panel of the unit is removable for gas hookup, servicing, and burner adjustment. The control panel must be removable after you install the unit.
Important: This unit should be installed
so that it can be removed at a later date if factory service is required. Any protrusion into the single sideburner enclosure may prevent the unit from sliding into place (see GAS SUPPLY PLUMBING REQUIREMENTS, on page 4).
ENSURING PROPER COMBUSTION AIR AND COOLING AIR FLOW
You must maintain proper air fl ow for your Fire Magic single sideburner to perform as it was designed (Fig. 4-1). If airfl ow is blocked, overheating and poor combustion will result. Make sure not to block the 1" front air inlet along the bottom of the control panel or more than 75% of the support grid surface with pans or griddles.
Installer and User Note:
Keep electrical supply cords away from all heated surfaces.
Fig. 4-1
Ventilation diagram
ELECTRICAL OUTLETS
Electrical outlets in the vicinity of this appliance
must be properly grounded and GFI equipped.
Important: This unit may be installed into
combustible framing (wood, for instance) provided there is a minimum of a
1
/2" airspace between the sides of the unit and any combustible material. This hanger requires 11/2" of countertop on each side and back to support the unit.
Fig. 4-1 Top View
Min. 1/2"
Max. 3/4" air gap to all combustible
material
2 1/4"
Hanger
Stainless
steel
hanger
1
2
/4"
Sideburner
Countertop
Edge of counter
cut-out
Fig. 4-2 Front View
Counter Counter
Sideburner
Maintain air gap all the
way down (back and
side) under countertop
Hanger
REV 6 - 0906231541
4
L-C2-18909
GAS SUPPLY PLUMBING REQUIREMENTS
1. CHECKING FUEL AND PROPER ORIFICES
Fire Magic units are equipped with orifi ces for natural gas, unless otherwise indicated. For use with propane gas, smaller orifi ces must be installed to avoid hazardous overheating. Please refer to Table 1 for the correct orifi ce size. Check the orifi ce size by following the instructions below. The drill size is stamped on the orifi ce. If the number is not visible you may have to remove the orifi ce (as detailed below) to read the number stamped on the side of the orifi ce.
IF YOU ARE NOT SURE YOU HAVE THE
CORRECT SIDEBURNER ORIFICE SIZE (OR
WISH TO CHANGE THE ORIFICE), FOLLOW THE
STEPS BELOW.
CAUTION: IF THE BURNER HAS BEEN IN USE,
WAIT UNTIL THE BURNER AND ITS COMPONENTS ARE COOL TO THE TOUCH.
a. Remove sideburner lid and lift off cooking
grid.
b. Remove the control knob and screws fi rst,
then carefully lift away the control panel. Important: Prior to fully removing the
control panel, you must disconnect the battery holder assembly wires that are located behind the control panel.
c. Reach up under the burner support and
remove the burner retaining clip (see Fig. 5-1), located at the rear of the burner pipe.
g. Replace the sideburner tube over the orifi ce,
aligning the burner over the electrode, taking care not to detach it from the wire.
h. Replace the burner retaining clip (underneath
burner), burner top, cooking grid, and lid.
Important: If converting the gas type, see the
CHECKING AND CONVERTING THE REGULATOR section before replacing the control panel.
i. Replace the control panel, being sure to
reconnect the battery holder assembly wires. Replace the control knob.
2. CONNECTING THE GAS SUPPLY TO YOUR FIRE MAGlC SINGLE SIDEBURNER
1
a. The burner manifold has a
/2" male fl are fi tting gas inlet elbow. A 1/2" female fl are fi tting connector nut is required to hook the gas supply to the burner.
b. Use a stainless steel fl ex connector to bring
the gas supply from the gas line stub or propane gas tank to the single sideburner manifold. A
1
/2" x 24" or 36" fl ex connector
is suitable for most installations.
CAUTION: Use only a C.S.A. listed stainless
steel fl ex connector. Do not use a rubber hose or plastic hose within the enclosure for your single sideburner; it will leak, resulting in an explosion and/or serious injury.
d. Remove the burner top and carefully lift
burner up and out, clearing the ceramic electrode (see Fig. 5-2), and pulling the burner tube away from the orifi ce, located on the end of the valve on the manifold at the front of the unit (see Fig. 5-3).
Note: You do not have to lift the burner completely
out of the unit to access the orifi ce.
e. Using a
3
/8" socket, remove orifi ce from the orifi ce holder (see Fig. 5-3) and check the number stamped on the orifi ce face.
f. If an orifi ce change is necessary, replace the
orifi ce with the correct sized one.
REV 6 - 0906231541
5
Fig. 5-1
Fig. 5-3
Fig. 5-2
ORIFICE IS LOCATED
Orifi ce is located at
AT THE END OF THE
the end of the valve
VALV E
No. L-C2-18909
Loading...