INSTALLER: Please leave these instructions with the consumer. CONSUMER: Retain for future reference.
INSTALLATION AND OPERATING INSTRUCTIONS
DANGER
IF YOU SMELL GAS:
1. Shut off the gas to the appliance.
2. Extinguish any open fl ame.
3. Open lid if equipped.
4. If odor continues, keep away from the appliance
and immediately call your gas supplier or fi re
department.
1. Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity
of this or any other appliance.
2. A propane cylinder not connected for use
shall not be stored in the vicinity of this or
any other appliance.
WARNING
WARNING
CODE AND SUPPLY REQUIREMENTS: This unit
must be installed in accordance with local codes and
ordinances, or, in the absence of local codes, with either
the latest National Fuel Gas Code (ANSI Z223.1/NFPA
54), CAN/CGA-B149.1 (Natural Gas Installation Code),
or CAN/CGA-B149.2 (Propane Installation Code).
This appliance and its individual shutoff valves must be
disconnected from the gas supply piping system when
testing the system at pressures in excess of ½ psig (3.5
kPa).
This appliance must be isolated from the gas supply
piping system by closing its individual manual shutoff
valves during any pressure testing of the gas supply
system at pressures up to and including ½ psig (3.5
kPa).
Certifi ed to: ANSI Z21.58-2007
CSA 1.6-2007
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Refer to this manual. For
assistance or additional information consult
qualifi ed, professional installer, service agency,
or the gas supplier.
All electrical outlets in the vicinity of the unit must be
properly grounded in accordance with local codes or, in
the absence of local codes, with the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1, which ever is applicable.
Keep all electrical supply cords and fuel supply hoses
away from any heated surface.
09-41
REV 6 - 0906231541
Robert H. Peterson Co. • 14724 East Proctor Avenue, • City of Industry, CA 91746
1
No. L-C2-18909
SIMPLE SIDEBURNER
Gaz naturel ou gaz de propane
Numéros de type 3279-(1,2)(P)
INSTALLATEUR : Veuillez laisser ces instructions avec le consommateur.
CONSOMMATEUR : Maintenez pour la future référence.
INSTALLATION ET CONSIGNES D'UTILISATION
DANGER
SI VOUS SENTEZ LE GAZ:
1. Coupez le gaz à l'appareil.
2. Éteignez-vous n'importe quelle fl amme nue.
3. Ouvrez le couvercle si équipé.
4. Si l'odeur continue, gardez à partir de l'appareil
et appelez immédiatement votre fournisseur ou
corps de sapeurs-pompiers de gaz.
CODE AND SUPPLY REQUIREMENTS: This unit
must be installed in accordance with local codes and
ordinances, or, in the absence of local codes, with either
the latest National Fuel Gas Code (ANSI Z223.1/NFPA
54), CAN/CGA-B149.1 (Natural Gas Installation Code),
or CAN/CGA-B149.2 (Propane Installation Code).
This appliance and its individual shutoff valves must be
disconnected from the gas supply piping system when
testing the system at pressures in excess of ½ psig (3.5
kPa).
This appliance must be isolated from the gas supply
piping system by closing its individual manual shutoff
valves during any pressure testing of the gas supply
system at pressures up to and including ½ psig (3.5
kPa).
Gardez tous les cordes d'alimentation électrique et tuyaux
de fourniture en combustible à partir de n'importe quelle
surface heated.
Robert H. Peterson Co. • 14724 East Proctor Avenue, • City of Industry, CA 91746
AVERTISSEMENT
1. Ne stockez pas ou n'employez l'essence ou
d'autres vapeurs et liquides infl ammables à
proximité de ceci ou d'aucun autre appareil.
2. Un cylindre de propane non relié pour l'usage
ne sera stocké à proximité de ceci ou d'aucun
autre appareil.
AVERTISSEMENT
L'installation, l'ajustement, le changement, le
service ou l'entretien inexact peuvent causer
des dommages ou des dégats matériels.
Référez-vous à ce manuel. Pour l'aide ou
les informations supplémentaires consultez
l'installateur qualifi é et professionnel, l'agence
de service, ou le fournisseur de gaz.
Toutes les sorties électriques à proximité de l'unité
doivent être correctement fondues selon des codes
locaux ou, en l'absence des codes locaux, avec le code
électrique national, ANSI/NFPA 70, ou le code électr ique
canadien, CSA C22.1, qui s'applique jamais.
Certifi é à la norme: ANSI Z21.58-2007
CSA 1.6-2007
09-41
REV 6 - 0906231541
2
L-C2-18909
SINGLE SIDEBURNER PARTS LIST
Item Description (Qty.)
No.
1.Cover, single burner
2a.Porcelain cast iron grid or
2b.Stainless steel grid
BTU per burner
Natural Gas Orifi ce
Propane Gas Orifi ce
Table 1 - Product data table
Single Side Burner
15,000 BTU
#50
#58
3
No. L-C2-18909
PLANNING FOR INSTALLATION OF YOUR SINGLE SIDE BURNER
WHERE TO INSTALL YOUR
SINGLE SIDEBURNER
FOR OUTDOOR USE ONLY.
Do not install this unit under unprotected
fl ammable surfaces. Do not install or use this
appliance inside a building, garage, or any
other covered area. It must not be used in or
on recreational vehicles or boats.
This is a built-in type unit designed to fi t into
open-front enclosures. The control panel of the
unit is removable for gas hookup, servicing, and
burner adjustment. The control panel must be
removable after you install the unit.
Important: This unit should be installed
so that it can be removed at a
later date if factory service is
required. Any protrusion into
the single sideburner enclosure
may prevent the unit from sliding
into place (see GAS SUPPLY
PLUMBING REQUIREMENTS,
on page 4).
ENSURING PROPER COMBUSTION AIR AND
COOLING AIR FLOW
You must maintain proper air fl ow for your Fire Magic
single sideburner to perform as it was designed
(Fig. 4-1). If airfl ow is blocked, overheating and
poor combustion will result. Make sure not to block
the 1" front air inlet along the bottom of the control
panel or more than 75% of the support grid surface
with pans or griddles.
Installer and User Note:
Keep electrical supply cords away from all heated
surfaces.
Fig. 4-1
Ventilation diagram
ELECTRICAL OUTLETS
Electrical outlets in the vicinity of this appliance
must be properly grounded and GFI equipped.
Important: This unit may be installed into
combustible framing (wood,
for instance) provided there is
a minimum of a
1
/2" airspace
between the sides of the unit
and any combustible material.
This hanger requires 11/2" of
countertop on each side and
back to support the unit.
Fig. 4-1 Top View
Min. 1/2"
Max. 3/4"
air gap to all
combustible
material
21/4"
Hanger
Stainless
steel
hanger
1
2
/4"
Sideburner
Countertop
Edge of
counter
cut-out
Fig. 4-2 Front View
CounterCounter
Sideburner
Maintain air gap all the
way down (back and
side) under countertop
Hanger
REV 6 - 0906231541
4
L-C2-18909
GAS SUPPLY PLUMBING REQUIREMENTS
1. CHECKING FUEL AND PROPER ORIFICES
Fire Magic units are equipped with orifi ces for
natural gas, unless otherwise indicated. For
use with propane gas, smaller orifi ces must
be installed to avoid hazardous overheating.
Please refer to Table 1 for the correct orifi ce
size. Check the orifi ce size by following the
instructions below. The drill size is stamped on
the orifi ce. If the number is not visible you may
have to remove the orifi ce (as detailed below)
to read the number stamped on the side of the
orifi ce.
IF YOU ARE NOT SURE YOU HAVE THE
CORRECT SIDEBURNER ORIFICE SIZE (OR
WISH TO CHANGE THE ORIFICE), FOLLOW THE
STEPS BELOW.
CAUTION: IF THE BURNER HAS BEEN IN USE,
WAIT UNTIL THE BURNER AND ITS
COMPONENTS ARE COOL TO THE
TOUCH.
a. Remove sideburner lid and lift off cooking
grid.
b. Remove the control knob and screws fi rst,
then carefully lift away the control panel.
Important: Prior to fully removing the
control panel, you must
disconnect the battery holder
assembly wires that are
located behind the control
panel.
c. Reach up under the burner support and
remove the burner retaining clip (see Fig.
5-1), located at the rear of the burner pipe.
g. Replace the sideburner tube over the orifi ce,
aligning the burner over the electrode,
taking care not to detach it from the wire.
h. Replace the burner retaining clip (underneath
burner), burner top, cooking grid, and lid.
Important:If converting the gas type, see the
CHECKING AND CONVERTING
THE REGULATOR section before
replacing the control panel.
i. Replace the control panel, being sure to
reconnect the battery holder assembly
wires. Replace the control knob.
2. CONNECTING THE GAS SUPPLY TO YOUR
FIRE MAGlC SINGLE SIDEBURNER
1
a. The burner manifold has a
/2" male fl are
fi tting gas inlet elbow. A 1/2" female fl are
fi tting connector nut is required to hook the
gas supply to the burner.
b. Use a stainless steel fl ex connector to bring
the gas supply from the gas line stub or
propane gas tank to the single sideburner
manifold. A
1
/2" x 24" or 36" fl ex connector
is suitable for most installations.
CAUTION: Use only a C.S.A. listed stainless
steel fl ex connector. Do not use a
rubber hose or plastic hose within the
enclosure for your single sideburner;
it will leak, resulting in an explosion
and/or serious injury.
d. Remove the burner top and carefully lift
burner up and out, clearing the ceramic
electrode (see Fig. 5-2), and pulling the
burner tube away from the orifi ce, located on
the end of the valve on the manifold at the
front of the unit (see Fig. 5-3).
Note: You do not have to lift the burner completely
out of the unit to access the orifi ce.
e. Using a
3
/8" socket, remove orifi ce from the
orifi ce holder (see Fig. 5-3) and check the
number stamped on the orifi ce face.
f. If an orifi ce change is necessary, replace the
orifi ce with the correct sized one.
REV 6 - 0906231541
5
Fig. 5-1
Fig. 5-3
Fig. 5-2
ORIFICE IS LOCATED
Orifi ce is located at
ATTHE END OF THE
the end of the valve
VALVE
No. L-C2-18909
Loading...
+ 9 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.