Automatic Grill Shut-off
1-Hour Timer
Model# 3092A
INSTALLER: Leave these instructions with consumer.
CONSUMER: Retain for future reference.
Note: This timer can be installed horizontally or
vertically. See Fig. 1-1 for horizontal setup and
Fig. 1-2 for vertical setup.
Fit the Automatic Grill Shut-Off Timer in the gas supply
line before the grill. The timer accommodates 1/2" NPT
piping (both ends).
Important: Ensure you connect the gas supply to
the side marked “IN” on the timer (see
photo). It MUST NOT be fi tted within 18"
of the grill, or it will overheat, causing
damage to the timer and may result in
a leak.
Use pipe joint compound on male fi ttings attached to
the timer.
To use, set the dial (turn clockwise) to the desired time to
shut off. The dial is marked in 3 twenty minute increments
(any position in between is an estimate of that set time).
The timer dial will auto rotate (counter-clockwise) and
will shut off the gas supply when the dial reaches OFF
(i.e. the time is completed).
Important: When using the timer for periods of less
than twenty minutes, you must first set
the dial to 20 minutes (to activate), then
return (counter-clockwise) to the desired
amount of time. This will ensure proper timer
operation. See Fig. 1-1 or Fig. 1-2.
Rated up to 100,000 BTUs /
Max temperature 125°F
Gas fl ow direction
(to grill)
Gas supply
side
Turn past
20 minutes
to activate
Fig. 1-1 Horizontal setup
Timer setting
mark
(shown here
in OFF)
Timer setting mark
(shown here in OFF)
Grill
side
Time settings:
20-60 minutes
Grill
side
ROBERT H. PETERSON CO. • 14724 East Proctor Avenue • City of Industry, CA 91746
REV 1 - 1610190850
Turn past
20 minutes
to activate
Gas fl ow
direction
(to grill)
Gas supply side
Time settings:
20-60 minutes
Fig. 1-2 Vertical setup
1