Firemagic 3092B User Manual

1-Hour Automatic Timer
IN
OFF
60
MINUTES
40
MINUTES
20
MINUTES
TURN
PAST
Model# 3092B
INSTALLER: Leave these instructions with consumer. CONSUMER: Retain for future reference.
SPECIFICATIONS
• 100,000 B.T.U., Natural Gas @ 0.6 SP. @ 7" w.c.
• 100,000 B.T.U., Propane Gas @ 1.53 SP.@ 11" w.c.
• Maximum working pressure not to exceed 1/2 P.S.I.G.
• Maximum ambient operating range: from 0° F (-18° C) to 150° F (65.6° C).
INSTALLATION REQUIREMENTS
• Timer MUST be installed in accordance with local codes or, in the absence of local codes, in accordance with the National Fuel Gas Code ANSI Z223.1/ NFPA54, or the Natural Gas & Propane Installation Code, CSA B149.1, as applicable.
• Timer MUST be installed in-line between the shut-off valve and the gas appliance.
• Timer MUST be installed a minimum of 18" away from the appliance or it will overheat, causing damage to the timer and may result in a leak.
• Timer MUST be installed within 6 feet of the appliance. If it is located within the appliance enclosure, it must be easily accessible.
• Timer MUST be protected from high temperatures and outdoor elements.
• Use pipe joint compound resistant to all gasses on all NPT fittings except flare fittings. Be sure to leak test at all connections.
(Setup may vary)
Shut-off valve (shown in-line) must be within 6 feet of the appliance
AND before the timer
Gas supply
(NPT)
Automatic
shut-off timer
(NPT-to-NPT)
Fig. 1-1 Timer installation overview
HORIZONTAL SETUP
Gas flow direction
(to appliance)
Gas supply
side (IN)
Timer must be a minimum of 18"
from the appliance
(max. 6 ft.)
Flare-to-NPT
adapter
Timer must be protected
from high temperatures and
outdoor elements
Flex
connector
Appliance
side
Gas
appliance
INSTALLATION
In addition to following the CONNECT GAS SUPPLY section of the gas appliance owner’s manual, install the timer in the gas supply line (between the shut-off valve and the appliance). See Fig. 1-1 and 1-2.
• Ensure you connect the line coming from the gas supply to the side marked “IN” on the timer.
• The timer accommodates 1/2" NPT piping (both ends).
• Follow ALL information found in the requirements section above, in the gas appliance owner’s manual, and in Fig. 1-1 and 1-2.
• The timer can be installed horizontally or vertically.
ROBERT H. PETERSON CO. • 14724 East Proctor Avenue • City of Industry, CA 91746
REV 1 - A - 1912031615
VERTICAL SETUP
Appliance
side
Gas flow direction
(to appliance)
Gas supply
side (IN)
Fig. 1-2 Timer installation detail
1
L-C2-559
OPERATION
To use, set the dial (turn clockwise) to the desired time to shut off. The dial is marked in 3 twenty minute increments (any position in between is an estimate of that set time). The timer dial will auto rotate (counter-clockwise) and will shut off the gas supply when the dial reaches OFF (i.e. the time is completed).
Important: When using the timer for periods of less
than twenty minutes, you must first set the dial to 20 minutes (to activate), then return (counter-clockwise) to the desired amount of time. This will ensure proper timer operation. See Fig. 2-1.
CAUTION: Always leave the shut-off valve in the OFF
position when not in use.
(Horizontal setup shown)
Timer setting mark
(shown here in OFF)
Turn past
20 minutes to
activate
(see important
in text)
Time settings: 20-60 minutes
Fig. 2-1 Timer operation
REV 1 - A - 1912031615
2
L-C2-559
Loading...