Firefox OGF - 2.7/ME, OGF - 3.0/ME, OGF - 3.5/ME Installation & Operating Instructions Manual

OGF - ME Series
OPEN GAS FIREBOX
INSTALLATION & OPERATING INSTRUCTIONS
MODELS:
OGF - 2.7/ME OGF - 3.0/ME OGF - 3.5/ME
FIREFOX INDUSTRIES PTY LTD
ACN 074 490 654
This appliance must be installed by authorized personnel in accordance with manufacturers instructions, gas fitting regulations, AGA 601 code for installation of gas burning appliances, electrical wiring regulations and any other statutory requirement. The guidelines here-in have been tested and approved to AS 4558/AG 108. AGA Approval No. 6386.
HOT AIR OUTLETS
FLUE SPIGOT
FIREFOX “OGF-ME” FIREBOX
CONTROL COVER PANEL
GAS INLET
COLD AIR INTAKE
FAN SWITCH
ELECTRIC CORD
GAS FIREGRATE
‘GFG’
For the appropriate Gas Firegrate ‘GFG’
to be used in conjunction with the Gas
Firebox (OGF). See specification pages
on the back of booklet.
G
A
S
E
N
T
R
Y
CONTROL COVER PANEL
DECORATIVE FRONT IRON
Spec 20.1.11 FC
OGF - ME Series
INSTALLATION REQUIREMENTS
DEFINITION
Installation of a Firefox OGF-ME series open fronted steel firebox into a non-combustible enclosure constructed partially of masonry e.g. brick, concrete or Hebel blocks in conjunction with the specified steel flueing system to draw and exhaust combustion gases up and away from the gas log firegrate.
1. Ensure that any air extraction devices located in the vicinity of the fireplace will not cause a negative air pressure (suction) which could cause a spillage of combustion gases into the room where the firebox is located when in operation.
2. GAS SUPPLY REQUIREMENT: Provide a 12mm (1/2”) copper gas pipe into the chamber with a tail approx. ¾ of the way into the firebox. An access hole is provided on the right hand side of the unit 130mm up from the base and 140mm in from the front of the unit. For MJ/HR rating of the gas firegrate burner refer to specification pages.
3. ELECTRICAL SUPPLY: The firebox is supplied with 1.5m of lead and a 3 pin plug located on the lower left hand side of the unit. The lead must not rise above 100mm of the base level of the firebox. If connecting to a wall mounted isolating switch, ensure that the switch is far enough away so as to not obstruct the fitting of a decorative surround i.e. mantelpiece.
4. Construct a non-combustible enclosure as required to suit the selected Firefox OGF-ME series gas firebox. The enclosure must completely surround the base, sides and back of the unit and rise 300mm above the top of the unit. Plasterboard can be Zero Clearance to the perimeter face flange of the unit.
5. FLUEING REQUIREMENTS: . Use the specified single skin galvanised inner active flue ONLY if the firebox and flue is to be
completely enclosed in masonry.
. Use the specified twin skin flue system i.e. galvanised inner active flue PLUS the galvanised
outer casing if the flue is to be exposed close to combustible materials i.e. timber framing. . Secure inner active flues at each crimp joint with 4 pop rivets. . Secure outer casings at each crimp joint with 4 x 25mm self tapping screws. . A 25mm clearance to all combustible materials is required from the outer flue casing. . Fit approved cowl as specified for the selected firebox/flue.
6. Permanent ventilation equal to the cross sectional area of the specified firebox flue must be provided into the room/area the gas fire is located.
7. Use only the appropriate Firefox gas firegrate/burner (GFG) in conjunction with the selected Firefox OGF/ME firebox See GFG Series (GAS FIREGRATE) specifications, located in the following pages.
For installation and commissioning procedure of the gas burner/firegrate (GFG) refer to separate details entitled: FIREFOX INSTALLATION & OPERATING INSTRUCTIONS ‘GFG’ Series GAS FIREGRATES.
1
OGF - ME Series
e.g. Open Gas Firebox Installation into a Masonry Enclosure
PLASTER
BOARD
F.L.
GAS ENTRY
6mm THK NON COMBUSTIBLE FOREHEARTH & BASE UNDER UNIT IF PLACING ON A COMBUSTIBLE FLOOR
ALIGN FACE OF FIREBOX FLUSH WITH PLASTERBOARD UNLESS OTHERWISE SPECIFIED
TIMBER FRAME
MASONRY
25mm CLEARANCE TO ALL COMBUSTIBLES WHEN USING TWIN SKIN FLUE
OUTER CASING ( SEE BELOW)
FIREFOX GAS FIREGRATE
USE TWIN SKIN
FLUE WHERE EXPOSED TO COMBUSTIBLE MATERIALS AND MAINTAIN 25mm CLEARANCE
600 MIN
ABOVE R/LINE
3600 MIN FLUE
RISE FROM TOP
OF UNIT
GAS COWL
INNER ACTIVE FLUE ( SEE BELOW)
115
EXAMPLE ONLY
This detail must be read in conjunction with manufacturers Installation Requirements & Operating Instructions.
25
NOTE: DO NOT LOCATE ANY EXTRACTION AIR DEVICE WHICH MAY CAUSE A NEGATIVE AIR PRESSURE IN THE ROOM WHERE THE GAS FIRE IS LOCATED
VENTILATION OF 400cm IS REQUIRED INTO THE ROOM WHERE THE GAS FIRE IS LOCATED, e.g. ROOF/CEILING SPACE, OUTSIDE WALL CAVITY OR SUB-FLR. AREA
PLUMBING & ELECTRICAL MUST BE CARRIED OUT BY AN AUTHORISED PERSON
275
B
OPTIONAL BRICK ENCLOSURE TO INNER SINGLE SKIN FLUE OR
USE SINGLE SKIN INNER FLUE ONLY WHERE FULLY ENCLOSED IN BRICKWORK
WRAP INSULATION BLANKET AROUND UNIT
ELEC. SUPPLY SWITCH
200 MIN.
300
MIN.
GAS ENTRY INPUT
FOREHEARTH
VARIABLE
(DEPENDS ON SELECTED SURROUND
CHECK SPEC. /SELECTION)
A
C
120
DIMENSIONAL REQUIREMENTS
CHECK DATA PLATE ON ‘GFG’ FOR CORRECT GAS TYPE
MODEL
OGF - 27-ME
OGF - 30-ME OGF - 35-ME
A
B
C
680
645
480
178
229
730
645
480
203
254
850
645
480
229
280
INNER
FLUE
OUTER
CASING
Mj/hr 36 42 52
GAS INPUT REQUIREMENTS
‘GFG’
2
OGF - ME Series
OPEN GAS FIREBOX SPECIFICATIONS
FRONT
TOP
RIGHT HAND SIDE
A
F
C
D
B
E
FLUE
SPIGOT
FLUE
SPIGOT
FAN
FAN
FAN
SWITCH
POWER SUPPLY
POWER
SUPPLY
GAS PIPE
INLET
GAS PIPE
INLET
C
FLUE
SPIGOT
30
140
115
75
A
75
OGF - 27/ME
OGF - 30/ME
OGF - 35/ME
GFG 2.7
GFG 3.0
GFG 3.5
GAS INPUT
36 - 35 Mj Hr
41 - 40 Mj Hr
52 - 50 Mj Hr
FIREBOX MODEL
FIREBOX DIMENSIONS
A B C D E F
720 640 370 160 620 605
780 640 390 155 680 605
900 640 405 155 800 605
178 (7”)
229 (9”)
203 (8”)
254 (10”)
229 (9”)
280 (11”)
} } }
APPROPRIATE GAS FIREGRATE ‘GFG’
FLUE INNER/OUTER
For installation and commisioning procedure of the Gas Firegrate/Burner ‘GFG’ refer to seperate instructions entitled; INSTALLATION & OPERATING INSTRUCTIONS ‘GFG’ Series FIREGRATES.
NG LP
3
OGF - ME Series
CLEARANCE TO COMBUSTIBLE DECORATIVE SURROUNDS
Decorative surrounds i.e. timber mantelpieces/combustible moulding must be 50mm (min) clear of the face side edges and top face edge of the firebox.
Upright legs and breast sections of combustible surrounds must not project further than 50mm (max) forward of the face of the firebox.
Mantle shelves must be 300mm (min) clear above the top edge of the firebox and must not project more than 250mm (max) forward of the face of the firebox.
A non-combustible floor protector (forehearth) at the base directly in front of the firebox opening must be a minimum of 6mm thick, project a minimum 300mm forward and 200mm on each side of the firebox opening.
MANTLEPIECE BREAST
G E L
0 5
N
I M
50
MIN
50
MAX
250
MAX
0 0 3
N
I M
FIREFOX
OGF UNIT
4
OGF - ME Series
USER INSTRUCTIONS
Congratulations on having a FIREFOX fan forced gas log fire installed in your home. We are sure it will provide you with many years of realistic fireside pleasure, comfort and enjoyment.
It is important that you familiarize yourself with the appliance by reading through these instructions.
If your installer has not shown you how to light the FIREFOX gas firegrate which has been fitted into the unit, refer to the separate booklet entitled INSTALLATION & OPERATING INSTRUCTIONS - GFG SERIES (Gas Firegrates
-L/C effect) under Lighting Burner & Commissioning and also familiarize yourself with the USER INSTRUCTIONS contained there-in.
Your FIREFOX gas firebox incorporates a sophisticated heat exchanger design which collects heat and a 2 speed fan which transfers the collected heat into the room/area where the FIREFOX is located. The fan control switch is located on the lower left hand front of the unit. The fan can remain OFF whilist the gas firegate is in operation. To boost heat output simply select one of the two fan speeds avaliable i.e. LOW or HIGH.
Your FIREFOX gas unit is relatively maintenance free. However we recommend that you have the appliance/installation checked once a year to ensure correct operation.
SAFETY PRECAUTIONS
As with any live naked flame burning apparatus, it is important in order to protect against personal injury or property damage to treat its operation with care and respect. A safety screen/fireguard should be used for the protection of children, elderly and infirm.
WARNING
DO NOT PLACE FOREIGN ARTICLES ON OR AGAINST THE APPLIANCE. DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THE APPLIANCE. DO NOT SPRAY AEROSOLS IN THE VICINITY OF THE APPLIANCE WHILST IN OPERATION. DO NOT USE GAS LOGS/COALS BURNERS OTHER THAN THAT SPECIFIED FOR THE APPLIANCE.
MAGNETIC TABS
SCREEN
LOCATING PINS
5