Finish Thompson Inc. hereby declares that the following motors fully comply with the applicable
health and safety requirements as specified be the EC Directives listed. This declaration is valid
provided that the devices are fully assembled and no modifications are made to these motors.
This manual pertains to S Series drum pump motors. Finish Thompson Inc. thanks you for choosing our products. We
believe that the use of our products will be fully satisfactory. When properly installed and operated, your Finish Thompson
motor and pump will provide long, trouble-free service; therefore, please read this manual carefully before carrying out
any operations on the pump/motor unit. Any use other than that described herein is considered incorrect; consequently,
Finish Thompson Inc. shall not be held responsible for any damages to people or things. In case of doubt or enquiries,
please apply to our Technical Service department directly at the following address:
1. The following terms and conditions apply to the sale of machinery, components and related services and products, of Finish Thompson Inc. (hereinafter “the products”)
2. Finish Thompson Inc. (the manufacturer) warrants only that:
a) its products are free of defects in material, design and workmanship at the time of original purchase;
b) its products will function in accordance with Finish Thompson Inc. operation manuals; Finish Thompson Inc. does not guarantee that the product will meet the precise needs of the Customer, except for those purposes set out in any invitation
to render documents or other documents specifically made available to Finish Thompson Inc. before entering into this
agreement;
c) high quality materials are used in the construction of the motors and that machining and assembly are carried out to the
highest standards. Except as expressly stated above, Finish Thompson Inc. makes no warranties, express or implied,
concerning the products, including all warranties of fitness for a particular purpose.
This warranty shall not be applicable in circumstances other than defects in material, design, and workmanship. In particular
warranty shall not cover the following:
d) Periodic checks, maintenance, repair and replacement of parts due to normal wear and tear;
e) Damage to the product resulting from:
i. Tampering with, abuse or misuse, including but not limited to failure to use the product for its normal purposes as
stated at the time of purchase or in accordance with Finish Thompson Inc. instructions for use and maintenance of the
product, or the installation or improper ventilation or use of the product in a manner inconsistent with the technical or
safety standard in force;
ii. Repairs performed by non-authorized service workshop, or opening of the unit by non-authorized personnel, or use of
non genuine Finish Thompson Inc. parts;
iii. Accidents, force majeure or any cause beyond the control of Finish Thompson Inc., including but not limited to light ning, water, fire, earthquake, and public disturbances, etc.
3. The warranty shall cover the replacement or repair of any part, which is documented to be faulty due to construction or as sembling, with new or repaired parts free of charge delivered by Finish Thompson, Inc. Parts subjected to normal wear and
tear shall not be covered by the warranty. Finish Thompson Inc. shall decide as to whether the defective or faulty part shall be
replaced or repaired. Transportation charges are prepaid to Finish Thompson.
4. The warranty of the products shall be valid for a period of 12 months from the date of delivery, under the condition that notice
of the alleged defect to the products or parts thereof be given to Finish Thompson, Inc. within the term of 8 days from the
discovery.
5. Repair or replacement under the terms of this warranty shall not give a right to an extension to, or a new commencement of,
the period of warranty. Repair or replacement under the terms of this warranty may be fulfilled with functionally equivalent re conditioned units. Finish Thompson Inc. qualified personnel shall be solely entitled to carry out repair or replacement of faulty
parts after careful examination of the motor. Faulty parts or components when replaced by Finish Thompson Inc. will become
the property of Finish Thompson Inc. If this warranty does not apply, the purchaser shall bear all cost for labor, material and
transportation.
6. Finish Thompson Inc. will not be liable on any claim, whether in contact, tort, or otherwise, for any indirect, special, incidental,
or consequential damages, caused to the customer or to third parties, including loss of profits, process down time, transpor tation costs, costs associated with replacement or substitution products, labor costs, installation or removal costs. In any and
all events, manufacturer’s liability shall not exceed the purchase price of the product and/or accessories.
7. Return Policy. Should you have any problems with this product, please contact the distributor in your area. The distributor will determine if a return to the factory is necessary and will contact the factory for a Return Authorization Number. Otherwise,
contact our Technical Service Hotline (1-800-888-3743) or email techservice@finishthompson.com if you have any questions
regarding product operation or repair.
2
Safety
1. Introduction
This manual contains all the information needed for the correct installation, use and maintenance of your new Finish Thompson
motor. It should be read and understood by all the personnel involved in installation, operating and servicing of the pump before it
is started.
2. Operator Qualification and Training
The personnel in charge of the installation, the operation and maintenance of the pump/motor must be qualified and able to
perform the operations described in this manual. Finish Thompson Inc. shall not be held responsible for the training level
of personnel and for the fact that they are not fully aware of the contents of this manual.
3. Safety Instructions
FOR YOUR OWN SAFETY
BEFORE using or servicing your pump, please make sure to wear the proper clothing, eye protection and follow standard safety
procedures when handling corrosive or personally harmful materials.
GENERAL DANGER
NEVER use a plastic pump or an open, splash-proof, TEFC or non-ATEX motor when pumping or mixing flammable or combus tible material.
ALWAYS use a Model EFS 316SS pump tube with Model S4 air motor and static protection kit with grounded discharge hose, P/N 107429, when pumping or mixing flammable or combustible material. Follow Assembly, Installation & Operating Instruc tions from manual, P/N J102721, included with the static protection kit or it can be accessed online at www.finishthompson. com/downloads.
ALWAYS use and store the pump and motor in an upright position.
DANGER: POWER SUPPLY
NEVER perform any maintenance operation on the motor while it is running or before it has been disconnected from the power supply. Avoid any possible hazard that might be caused by electric power.
ALWAYS check the electrical specifications on the motor data plate and make sure they correspond to the power supply to which it will be connected.
ALWAYS place motor in the OFF position prior to connecting the power source.
NEVER immerse the motor in liquid.
4. Noise Level
S1, S2, and S3 electric motors in normal operating conditions produce a sound level equal to or less than 74 dBA at a distance
of three feet (~ one meter). S4 Air motor produces a sound level equal to or less than 78 dBA at a distance of three feet (~ one
meter)
5. Modifications and Spare Parts
Any changes concerning the service of the motor/pump as originally purchased can be executed only after written approval
from Finish Thompson Inc. It is recommended to use only genuine Finish Thompson Inc. spare parts and approved accessories.
The use of non-original spare parts or non-approved accessories will void warranty and remove any responsibility on the manu facturer’s behalf for any damage caused to people or things.
3
INSTALLATION
1. Unpack motor and pump tube from carton. Check for shipping damage. If damage is detected, save the packaging and notify
the carrier immediately.
2. If motor and pump tube are boxed separately, the motor will need to be fastened to the pump tube. See figures 1 & 2.
Figure 1
Figure 2
3. Place the motor upside down on a tabletop surface with the coupling facing upwards and place the yellow coupling insert (item
1 from the pump manual) onto the motor’s coupling. See figures 3 & 4.
Figure 3
4. Position the pump tube upside down onto the motor. For electric motors, align the discharge spout of the pump facing away
from the handle of the motor. See figure 5. For air motors, the ball valve & muffler should be aligned with the discharge spout
for ease of operation. See figure 6.
Figure 4
Figure 5
Figure 6
5. Firmly press the pump tube onto the motor until it is fully seated. A slight twist may be necessary for the coupling splines to line
up properly.
6. Align the 4 bolt holes in the pump to the 4 holes in the motor, and fasten with 4 flat washers (item 7) and 4 screws (item 8).
Tighten using a # 2 Phillips head screwdriver. See figures 7 & 8. [Note: The EFS (316SS) model does not use the 4 flat
washers. Hand-tighten, being careful not to over-torque and strip the plastic.]
Figure 7
Figure 8
7. Using a SS hose clamp, secure a ¾” ID chemically compatible reinforced hose to the discharge spout of the pump.
4
OPERATION
Electric motor - Check that the motor switch is in the center “O” OFF position, and then plug the power cord into an outlet. Insert
the pump tube into the fluid to be dispensed and the discharge hose into the container to be filled. While holding the motor handle
and hose, switch the motor to the “I” low speed. The fluid will begin to pump. If more flow is desired, switch the motor to the “II”
high speed setting. See figure 9 below. If the motor stops working and the reset button has popped out, press the switch to the
off position “O”. Review your application to make sure it is within the capabilities of the pump (reset button pops typically from an
overloading situation). Allow the motor to cool down for at least 30 minutes and then press in the reset button located on the side of
the motor handle. See figure 9.
Air motor – Turn the air motor ball valve to the closed position. Attach the air motor to an air supply line filtered, lubricated (use
detergent SAE #10 oil) and regulated to 40 psi and 27 CFM using a ¼” FNPT fitting. (Note: Finish Thompson offers an optional Filter
/ Lubricator, P/N A100009.) Insert the pump tube into the fluid to be dispensed and the hose in the container to be filled. While
holding the air motor ball valve and hose, slowly turn the valve to the desired flow rate. (Note: Pump performance will vary depending on air pressure & volume.) See figure 10 below.
Figure 9
Figure 10
Pump – The EFP & EFV model pumps have a built in hose & cord clip. You can use these clips to store your hose and keep the plug
off the floor free of damage & corrosion. When selecting a discharge hose you should use a ¾” ID reinforced chemically compatible
hose secured with a SS hose clamp. See figures 11 & 12 below.
Note: All testing was performed with water at 68oF. Actual performance can vary by +/- 10%.
Actual performance will decrease with increased fluid viscosity and specific gravity. Viscosity and
performance are based on electric motor at high speed.
(30.3) (37.8)
Flow - USGPM(LPM)
7 gpm27 lpm 5 gpm 19 lpm 3.7 gpm 14 lpm
16 feet (4.9 m)
(45.4)
(52.9)
(60.5)
Viscosity performance based on electric motor at high speed.
6
(68.1)
PARTS LIST – ELECTRIC MOTORS
Models S1, S2 & S3
45
3
2
8
1
10
11
12
6
7
9
ITEMQTYDESCRIPTIONPART NUMBER
MODEL S1MODEL S2MODEL S3
11115V US CORD107215N/AN/A
11230V EU CORDN/A107216N/A
11115V UK CORDN/AN/A107216-1
21TRIAC ASSEMBLY - 115V107265-1N/A107265-1
21TRIAC ASSEMBLY - 230VN/A107265-2N/A
31ON/OFF SWITCH107304107304107304
41CIRCUIT BREAKER COVERJ100789J100789J100789
51CIRCUIT BREAKER - 115v107326N/A107326
51CIRCUIT BREAKER - 230vN/A107327N/A
61MOTOR COVER107065107065107065
71MOTOR CANISTER107066107066107066
81MOTOR - 115V107301N/A107301
81MOTOR - 230VN/A107302N/A
96HI-LOW SCREW - SSJ101020J101020J101020
101COUPLING HALF 107300107300107300
112LOCK WASHER - SS106322106322106322
122SOCKET HEAD CAP SCREW - SS107303107303107303
N/S1COUPLING INSERTJ103422J103422J103422
N/S - Not ShownN/A - Not Applicable
7
PARTS LIST - AIR MOTOR
Model S4
MODEL S4 PARTS LIST
ITEMQTYDESCRIPTIONPART NO.
11AIR MOTOR ONLYJ100032
21AIR MOTOR ADAPTER107073
31COUPLING HALFJ103934
41NIPPLEJ100107
51HEX REDUCER BUSHINGJ100057
61BALL VALVE J100073
71UNION - BRASSJ100036
82SET SCREWJ100040
91MUFFLERJ100033
N/S1AIR MOTOR REPAIR KITJ100060
N/S1OPTIONAL - FILTER / LUBRICATORA100003
N/S1COUPLING INSERTJ103422
N/S - NOT SHOWN
Tech Service 1-800-888-3743
techservice@nishthompson.com
Literature ID No. FT09- 1103
PN 107318
Loading...