Finish Thompson M3V-UK 103013 User Manual

MV Series Motors
Operation & Parts Manual
Models M3V, M5V, M5V-US
For use with M3V s/n 101058 & above, M3V-US s/n 103013 & above, M5V & M5V-US s/n 102973 & above.
EU Declaration of Conformity
Finish Thompson Inc. hereby declares that the following electrical equipment fully complies with the applicable health and safety requirements as specified be the EC Directives listed. The product may not be taken into service until it has been established that the driven Drum and Container Pump complies with the provisions of all relevant EC Directives. The complete product complies with the provisions of the EC Directive on machinery safety provided pumps manufactured by Finish Thompson Inc. are used. This declaration is valid provided that the devices are fully assembled and no modifications are made to these devices.
Type of Device:
Electric Motors for Driving Drum
and Container Pumps
Models:
M3V-UK M5 M5T M5V M5X M13 M54
M56 M59P M59H S2 S3
EC Directives:
Low Voltage Equipment (2006/95/EC)
Electromagnetic Compatibility (2004/108/EC)
Applied Harmonized Standards:
EN 60335-1 EN 60335-2-41 EN 55014-1 EN 55014-2
EN 60529
Manufacturer:
Finish Thompson Inc.
921 Greengarden Road
Erie, Pennsylvania 16501-1591 U.S.A
Signed,
_
President
January 7, 2013
Introduction
This manual pertains to drum pump motors MV Series. Finish Thompson, Inc. thanks you for choosing our products. We believe the use of our products will be fully satisfactory. When properly installed and operated, your Finish Thompson motor and pump will provide long, trouble-free service; therefore please read this manual carefully before carrying out any operations on the pump-motor unit. Any use other than that described herein is considered incorrect and; conse­quently, Finish Thompson, Inc. shall not be held responsible for any damages to people or things. In case of doubt or enquiries, please apply to our Technical Service department directly at the following address:
Finish Thompson, Inc.
921 Greengarden Rd.
Erie, PA 16501 U.S.A.
Tel. 1-814-455-4478 Fax 1-814-455-8518
www.finishthompson.com
fti@finishthompson.com
Index
Introduction . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . ..1
General Terms & Conditions, Warranty . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. 2
Safety .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. 3
Installation ............................................................................4
Operation, Specifications & Identification ................................................5
Parts .................................................................................6
1
WARRANTY, GENERAL TERMS & CONDITIONS
1. The following terms and condition apply to the sale of machinery, components and related services and products, of Finish Thompson Inc. (hereinafter “the products”).
2. Finish Thompson Inc. (the manufacturer) warrants only that:
a.) its products are free of defects in material, design and workmanship at the time of original purchase b.) its products will function in accordance with Finish Thompson Inc. operation manuals; Finish Thompson Inc. does
not guarantee that the product will meet the precise needs of the Customer, except for those purposes set out in any invitation to render documents or other documents specifically made available to Finish Thompson, Inc. before entering into this agreement
c.) high quality materials are used in the construction of the pumps and that machining and assembly are carried
out to the highest standards. Except as expressly stated above, Finish Thompson, Inc. makes no warranties, express or implied, concerning the products, including all warranties of fitness for a particular purpose.
3. This warranty shall not be applicable in circumstances other than defects in material, design, and workmanship. In particular, this warranty shall not cover the following:
a.) Periodic checks, maintenance, repair and replacement of parts due to normal wear and tear;
b.) Damage to the product resulting from: i. tampering with, abuse or misuse, including but not limited to failure to use the product for its normal
purposes as stated at the time of purchase or in accordance with Finish Thompson, Inc. instructions for use and maintenance of the product, or the installation or improper ventilation or use of the product in a manner inconsistent with the technical or safety standard in force
ii. repairs performed by non-authorized service workshop, or opening of the unit by nonauthorized personnel, or
use of non genuine Finish Thompson, Inc. parts
iii. accidents, acts of God or any cause beyond the control of Finish Thompson, Inc., including but not limited to
lightning, water, fire, earthquake, and public disturbances, etc.
4. This warranty shall cover the replacement or repair of any part(s), which is documented to be faulty due to construc­tion or assembling, with a new or repaired part(s) free of charges delivered by Finish Thompson, Inc. Part(s) subject­ed to normal tear and wear shall not be covered by the warranty. Finish Thompson, Inc. shall decide as to whether the defective or faulty part shall be replaced or repaired. Transportation charge is prepaid to Finish Thompson.
5. The warranty of the products shall be valid for a period of 12 months from the date of delivery, under the condition that notice of the alleged defect to the product(s) or part(s) thereof be given to Finish Thompson Inc. in writing within the term of 8 days from the discovery.
6. Repair or replacement under the terms of the warranty shall not give a right to an extension to, or a new commence­ment of, the period of warranty. Repair or replacement under the terms of this warranty may be fulfilled with func­tionally equivalent, reconditioned units. Finish Thompson Inc. qualified personnel shall be solely entitled to carry out repair or replacement of faulty parts after careful examination of the motor. Faulty parts or components when re­placed by Finish Thompson Inc. will become the property of Finish Thompson Inc. If this warranty does not apply, the purchaser shall bear all cost for labor, material and transportation.
7. Finish Thompson Inc. will not be liable on any claim, whether in contact, tort, or otherwise, for any indirect, special,
incidental, or consequential damages, caused to the customer or to third parties, including loss of profits, process down time, transportation costs, costs associated with replacement or substitution products, labor costs, installation or removal costs. In any and all events, manufacturer’s liability shall not exceed the purchase price of the product and/or accessories.
8. Return Policy. Should you have any problems with this product, please contact the distributor in your area. The distributor will determine if a return to the factory is necessary and will contact the factory for a Return Authorization Number. Otherwise, contact our Technical Service Hotline (1-800-888-3743) or email techservice@finishthompson. com if you have any questions regarding product operation or repair.
2
SAFETY
1. Introduction
This manual contains all the information needed for the correct installation, use and maintenance of your new Finish
Thompson motor. It should be read and understood by all the personnel involved in installation, operating and servic­ing of the pump before it is started.
2. Operator Qualification and Training
The personnel in charge of the installation, operation and maintenance of the pump unit we produce must be quali-
fied and able to perform the operations described in this manual. Finish Thompson Inc. shall not be held responsible for the training level of personnel and for the fact that they are not fully aware of the contents of this manual.
3. Safety Instructions
FOR YOUR OWN SAFETY:
BEFORE UNDERTAKING ANY SERVICE OPERATION ON YOUR MOTOR OR PUMP, PLEASE MAKE SURE TO WEAR THE
PROPER PROTECTIVE GEAR.
GENERAL DANGER
NEVER use a plastic pump or an open, splash-proof, TEFC or non-ATEX motor when pumping or mixing flammable or
combustible material.
ALWAYS use and store the pump and motor in an upright position.
DANGER: POWER SUPPLY
NEVER perform any maintenance operation on the motor while it is running or before it has been disconnected from
the power supply. Avoid any possible hazard that might be caused by electric power.
ALWAYS check the electrical specifications on the motor data plate and make sure they correspond to the power
supply to which it will be connected.
ALWAYS place motor in the OFF position prior to connecting the power source.
NEVER immerse the motor in liquid.
4. Noise Level
MV Motors in normal operating conditions produce a sound level equal or less than 79 dBA at a distance of three feet
(~ one meter).
5. Modifications and Spare Parts
Any changes concerning the service of the motor as originally purchased, can be executed only after written approval
from Finish Thompson Inc. It is recommended to use only genuine Finish Thompson Inc. spare parts and approved accessories. The use of non original spare parts or non approved accessories will void warranty and removes any responsibility on our behalf for any damage caused to people or things.
3
INSTALLATION
1. Unpack motor from carton. Check for shipping damage. If damage is detected, save the packaging and notify the carrier immediately.
2. Loosen the nut on the motor housing by turning it counterclockwise (as viewed from the bottom of the motor). Note that the nut remains on the motor even when loosened. See figure 1.
3. Looking into the bottom/drive-end of the motor, align the coupling half with the coupling half orientation of the pump. Aligning the coupling half with two of the slots in the motor adapter sleeve is recommended to provide a reference point. See figures 2 & 3.
4. Make sure that the rubber coupling insert (provided with the pump) is properly installed in the pump coupling half.
5. With the motor coupling half properly aligned, firmly push the motor down over the pump head until fully engaged. See figure 3.
6. The motor isn’t fully coupled unless the bottom of the motor and the top of the pump are completely flush. See figure 4.
Warning: Do not position the motor handle and cord over and in front of the pump discharge. Position it in line with
the discharge or at 90° to the discharge.
7. Manually tighten the nut by turning it clockwise until secure. See figure 5.
Note: Do not use hand tools to tighten the nut as this may cause damage to the motor casing.
Figure 1
Figure 2
Figure 3
Figure 4 Figure 5
4
OPERATION
The MV Series motors incorporate an ON/OFF switch as well as a Variable Speed Control. When operating the MV Se­ries for the first time it is recommended to turn down the speed control (Counter Clockwise) to the lowest setting. Make sure the discharge hose is properly secured. Turn on the motor with the ON/OFF switch & adjust the speed control to the desired flow rate. Both of these operations can be done with the same hand being used to support the pump utilizing the thumb. Keep in mind that flow rates will vary depending upon fluid viscosity & specific gravity. It may be necessary to operate the pump at a lower speed for high viscosity fluids. Contact factory for troubleshooting tips.
Motor Specifications
Model
Part Number 106655 106658 106657
Nominal Voltage 115v 230v 230v
Input Power HP / Watts .8 / 650 .8 / 650 .8 / 650
Hertz 50 / 60
RPM’s (Variable Speed) 3,500-10,000
Enclosure 3(WP) Splash-Proof IP24 Splash-Proof
Certificates or Approvals
Max Viscosity cps / Density 500 / 1.8
Duty Cycle Continuous *
Applicable Pump Models PF / TB / TBP
*Contact Factory for brush life information.
M3V M5V M5V-US
MOTOR IDENTIFICATION
(M3V Sample Label)
Model: M3V Part No: 106655 Serial No.: 12345-A09
Output: 4/5 HP, 115 VAC, 50/60 Hz Enclosure: 3 (WP) Splashproof LR157411 Thermally Protected
Date of Manufacture: 3/31/2009
5
PARTS
Note: Housing Repair Kit includes handle, cover, base, nut and labels.
Item Qty Description Part Number
Speed Control Assy
1 1
2 1
3 1
4 1
5 1
6 1
7 1
8 1
9 1
10 1
11 1
M3V 108322-1 M5V 108322-2
Switch, On\Off
All models 106029
Cord
M3V, 115 volt 106648 M5V-US, 230 volt 106665 M5V, 230 volt 106666
Motor Coupling
All models J100012-2
Fan Blade
All models 106027
Circuit Breaker
M3V 108321 M5V, M5V-US 107064
Housing Repair Kit
All models 108376
Housing Nut
All models 106541
Speed Control Knob
All models 106538
On/Off Switch Knob Assembly
All models 107225
Brush Kit
M3V 108385-1 M5V 108385-2
Tech Service 1-800-888-3743 techservice@nishthompson.com Literature ID No. FT09-1080 Part No. 106237, R12, 5/22/13