Drum Pump Flow Meter
Model FMBC2000 Series
Operating Instructions
Table of Contents
Safety 1
Introduction ........................................................................................................................................................ 1
Specificatons ..................................................................................................................................................... 1
Features ............................................................................................................................................................. 1
Section 1 - Installation ....................................................................................................................................... 2
Section 2 - Operation ......................................................................................................................................... 2
Front Panel Display ................................................................................................................................ 3
Batch Control Mode ............................................................................................................................... 3
Programming Menu Flow Chart .............................................................................................................. 4
Calibration ............................................................................................................................................. 4 - 6
Programming Batch Control ................................................................................................................... 6
Jumper Position ..................................................................................................................................... 7
Factory Default Chart .............................................................................................................................. 7
Section 3 - Maintenance .................................................................................................................................... 7
Section 4 - Warranty .......................................................................................................................................... 8
Section 5 - Spare Parts ...................................................................................................................................... 8
Safety
ALWAYS wear protective clothing, eye protection and follow standard safety procedures when handling
corrosive or personally harmful materials.
NEVER use this flow meter with flammable or combustible liquids.
NEVER use this flow meter in a hazardous environment.
ALWAYS verify chemical compatibility with the flow meter and pump materials of construction before operation.
ALWAYS make sure the pump and hose are properly supported.
ALWAYS use a chemically compatible hose rated for the temperature of the product being pumped.
ALWAYS place pump tube in liquid before starting.
Introduction
Thank you for purchasing an FMBC-2000 Series electronic flow meter. The FMBC-2000 Series is designed to measure the flow of a fluid being
dispensed from Finish Thompson’s PFP, PFM, & PFV drum pumps. In addition, the meter can stop the pump when a predetermined customer
adjustable volume is reached (Batch Control Mode). The meter is factory calibrated and displays information on an LCD display. In addition, the
meter can be field calibrated to improve accuracy at a given flow rate. There are options for materials of construction and measurement units.
Specifications
Maximum Working Pressure: 35-62 PSIG (2.4 – 4.3 bar)
Maximum Fluid Temperature: PFM & PFP Models = 160º F (71º C); PFV = 120º F (49º C)
Ambient Temperature Range: 32º to 110ºF / 0º to 43º C
Enclosure: NEMA 4X (IP56)
Sensor/Paddle/Axle Material: PVDF
O-ring seals: Viton
Accuracy: +/-1% of full-scale rate reading; can be field calibrated
Repeatability: +/-1% of full-scale rate reading
Power Requirements: 15 volt DC from supplied AC transformer (115 or 230 volt options)
Maximum Viscosity: 20 cP/mPas
Maximum Specific Gravity: 1.8
Features
• Easy to read eight digit LCD display
• Installs quickly on PFM, PFP, PFV Series pump tubes with supplied fittings
• Factory calibrated; can be field calibrated using front panel touch buttons
• Minimal maintenance required
• Corrosion resistant PVDF sensor with polypropylene or PVDF body, ABS electronics enclosure
• Weather resistant enclosure
• High accuracy
• Batch control
• Hall effect sensor
• Non-volatile memory stores settings even when power is disconnected
Kit Contents:
• FMBC-2000 Series Meter - prewired
• Flow meter adapter
• Discharge nut
• 1” NPT coupling
• Hose barb adapter
1