Finish Thompson FM3000 User Manual

Drum Pump Flow Meter
Model FM3000 Series Operating Instructions
Table of Contents
Safety ................................................................................................................................................................ 1
Introduction ........................................................................................................................................................ 1
Specificatons ..................................................................................................................................................... 1
Features ............................................................................................................................................................. 1
Section 1 - Installation ....................................................................................................................................... 2
Section 2 - Operation ......................................................................................................................................... 2
Section 3 - Maintenance .................................................................................................................................... 3
Section 4 - Warranty .......................................................................................................................................... 3
Section 5 - Spare Parts ...................................................................................................................................... 3
Safety
ALWAYS wear protective clothing, eye protection and follow standard safety procedures when handling corrosive or personally harmful materials.
NEVER use this flow meter in a hazardous environment.
ALWAYS verify chemical compatibility with the flow meter and pump materials of construction before operation.
ALWAYS make sure the pump and hose are properly supported.
ALWAYS use a chemically compatible hose rated for the temperature of the product being pumped.
ALWAYS place pump tube in liquid before starting.
Introduction
Thank you for purchasing an FM-3000 Series electronic flow meter. The FM-3000 Series is designed to measure the flow of a fluid being dispensed from Finish Thompson’s PFP, PFM, & PFV drum pumps. The meter is factory calibrated and displays information on an LCD display. In addition, the meter can be field calibrated to improve accuracy at a given flow rate. One lithium battery powers the unit.
FM-3000 is a rate/totalizer meter – designed to measure and display both the rate of flow and the total flow. In addition, it stops the pump motor when a preset liquid volume has been pumped.
Specifications
Maximum Working Pressure: 35-62 PSIG (2.4 – 4.3 bar)
Maximum Fluid Temperature: PFM & PFP Models = 86º F (30º C)
Ambient Temperature Range: 32º to 140ºF / 0º to 60º C
Enclosure: Splash resistant
Sensor/Paddle/Axle Material: PVDF/PVDF/Hastelloy C
O-ring seals: Viton
Accuracy: +/-1.0% of full-scale rate reading; can be field calibrated
Repeatability: +/-.05% of full-scale rate reading
Power Requirements: One 3.6V lithium, AA battery included
Battery Life Expectancy: 1 year minimum
Maximum Viscosity: 20 cP/mPas
Maximum Specific Gravity: 1.8
Features
• Easy to read two (6) digit LCD display
• Installs quickly on PFM, PFP, PFV Series pump tubes with supplied fittings
• Batch control feature stops pump motor when preset volume has been pumped
• Displays either US gallons or liters
• Digital flow indicator
• Factory calibrated; can be field calibrated using front panel touch buttons
• Four ranges allow the meter to be calibrated and stored for different fluids or flow rates and can be totaled independently
• Minimal maintenance required
• Corrosion resistant PVDF sensor with polypropylene body
• Splash resistant enclosure
• High accuracy
• Meter automatically turns on and begins operation when flow is detected
• Extended battery life mode – display switches off after 2 minutes without flowLow battery warning
• Non-volatile memory stores settings even when batteries are removed
Kit Contents:
• FM-3000 Series Meter
• Flow meter adapter
• Discharge nut
• 1” NPT x 1” BSPP coupling
• 1” BSPP x hose barb adapter
• (2) Viton o-rings