Finisar’s FTLX1471D3BCL 10Gb/s Enhanced Small Form Factor Pluggable SFP+
transceivers are designed for use in 10-Gigabit Ethernet links up to 10km over Single
Mode fiber. They are compliant with SFF-84311, SFF-84322 and IEEE 802.3ae
10GBASE-LR/LW
functions are available via a 2-wire serial interface, as specified in SFF-84725. The
FTLX1471D3BCL is a “limiting module”, i.e., it employs a limiting receiver. Host board
designers using an EDC PHY IC should follow the IC manufacturer’s recommended
settings for interoperating the host-board EDC PHY with a limiting receiver SFP+
module. The transceiver is RoHS compliant and lead free per Directive 2002/95/EC6, and
Finisar Application Note AN-20387.
PRODUCT SELECTION
3
, and 10G Fibre Channel 1200-SM-LL-L4 Digital diagnostics
FTLX1471D3BCL Datacom SFP+ Product Specification – February 2009
A
A
I. Pin Descriptions
Pin Symbol Name/Description Ref.
1 V
2 T
3 T
EET
FAULT
Transmitter Disable. Laser output disabled o n hi g h or open. 3
DIS
4 SDA 2-wire Serial Interface Data Line 2
5 SCL 2-wire Serial Interface Clock Line 2
6 MOD_ABS Module Absent. Grounded within the module 2
7 RS0 Rate Select 0. Not Used. 4
8 RX_LOS Loss of Signal indication. Logic 0 indicates normal operation. 5
9 RS1
10 V
11 V
12 RD-
EER
EER
13 RD+ Receiver Non-inverted DATA out. AC Coupled.
14 V
15 V
16 V
17 V
EER
Receiver Power Supply
CCR
Transmitter Power Supply
CCT
EET
18 TD+ Transmitter Non-Inverted DATA in. AC Coupled.
19 TD20 V
EET
Notes:
1. Circuit ground is internally isolated from chassis ground.
2. T
is an open collector/drain output, which should be pulled up with a 4.7k – 10k Ohms resistor on
FAULT
the host board if intended for use. Pull up voltage should be betwee n 2. 0 V t o Vcc + 0.3V . A high
output indicates a transmitter fault caused by either the TX bias current or the TX output power
exceeding the preset alarm thresholds. A low output indicates normal operation. In the low state, the
output is pulled to <0.8V.
3. Laser output disabled on T
4. Internally pulled down per SFF-8431 Rev 2.0.
5. LOS is open collector output. Should be pulled up with 4.7k – 10kΩ on host board to a voltage
between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.
Figure 1. Diagram of Host Board Connector Block Pin Numbers and Names.
Transmitter Ground 1
Transmitter Fault 2
Rate Select 1. Not Used. 4
Receiver Ground 1
Receiver Ground 1
Receiver Inverted DATA out. AC Coupled.
Receiver Ground 1
Transmitter Ground 1
Transmitter Inverted DATA in. AC Coupled.
Transmitter Ground 1
FTLX1471D3BCL Datacom SFP+ Product Specification – February 2009
II. Absolute Maximum Ratings
Exceeding the limits below may damage the transceiver module permanently.
Parameter Symbol Min Typ Max Unit Ref.
Maximum Supply Voltage Vcc -0.5 4.0 V
Storage Temperature T
S
Relative Humidity RH 0 85 % 1
1. Non-condensing.
III. Electrical Characteristics
Parameter Symbol Min Typ Max Unit Ref.
Supply Voltage Vcc 3.14 3.30 3.46 V
Supply Current Icc 200 285 mA
Transmitter
Input differential impedance Rin 100
Differential data input swing Vin,pp 180 700 mV
Transmit Disable Voltage VD 2 Vcc V
Transmit Enable Voltage V
Receiver
Differential data output swing Vout,pp
Output rise time and fall time Tr, Tf 28 ps 3
LOS Fault V
LOS Normal V
Power Supply Noise Tolerance VccT/VccR
Notes:
1. Connected directly to TX data input pins. AC coupling from pins into laser driver IC.
2. Into 100Ω differential termination.
3. 20 – 80%. Measured with Module Compliance Test Board and OMA test pattern. Use of four 1’s and
four 0’s sequence in the PRBS 9 is an acceptable alternative. SFF-8431 Rev 3.0.
4. LOS is an open collector output. Should be pulled up with 4.7kΩ – 10kΩ on the host board. Normal
operation is logic 0; loss of signal is logic 1.
5. See Section 2.8.3 of SFF-8431 Rev 3.0.
6. The FTLX1471D3BCL is a “limiting module”, i.e., it employs a limiting receiver. Host board designers
using an EDC PHY IC should follow the IC manufacturer’s recommended settings for interoperating
the host-board EDC PHY with a limiting receiver SFP+ module.
IV. Optical Characteristics (T
(TOP = -5 to 70 °C, VCC = 3.14 to 3.46 Volts)
EN
LOS fault
LOS norm
= -5 to 70 °C, V
OP
Parameter Symbol Min Typ Max Unit Ref.
Transmitter
Optical Modulation Amplitude
(OMA)
Average Launch Power P
Optical Wavelength
Side-Mode Suppression Ratio SMSR
Optical Extinction Ratio ER
Transmitter and Dispersion Penalty TDP 3.2 dB
Average Launch power of OFF
transmitter
Tx Jitter
FTLX1471D3BCL Datacom SFP+ Product Specification – February 2009
Receiver
Receiver Sensitivity (OMA)
@ 10.3Gb/s
Stressed Receiver Sensitivity
(OMA) @ 10.3Gb/s
Average Receive Power P
Optical Center Wavelength
Receiver Reflectance Rrx -12 dB
LOS De-Assert LOS
LOS Assert LOS
LOS Hysteresis
Notes:
1. Average power figures are informative only, per IEEE 802.3ae.
2. Valid between 1260 and 1355 nm. Measured with worst ER; BER<10
3. Valid between 1260 and 1355 nm. Per IEEE 802.3ae.
V. General Specifications
Parameter Symbol Min Typ Max Units Ref.
Bit Rate BR 9.95 10.5 Gb/s
Bit Error Ratio BER 10
Max. Supported Link Length L
Notes:
1. 10GBASE-LR, 10GBASE-LW, 1200-SM-LL-L 10GFC.
2. Tested with a 2
31
– 1 PRBS.
VI. Environmental Specifications
Finisar FTLX1471D3BCL transceivers have an operating temperature range from -5°C to
+70°C case temperature.
Parameter Symbol Min Typ Max Units Ref.
Case Operating Temperature T
Storage Temperature T
VII. Regulatory Compliance
Finisar transceivers are Class 1 Laser Products and comply with US FDA regulations.
These products are certified by TÜV and CSA to meet the Class 1 eye safety
requirements of EN (IEC) 60825 and the electrical safety requirements of
EN (IEC) 60950. Copies of certificates are available at Finisar Corporation upon request.
FTLX1471D3BCL Datacom SFP+ Product Specification – February 2009
VIII. Digital Diagnostic Functions
Finisar FTLX1471D3BCL SFP+ transceivers support the 2-wire serial communication
protocol as defined in the SFP MSA1. It is very closely related to the E2PROM defined in
the GBIC standard, with the same electrical specifications.
The standard SFP serial ID provides access to identification information that describes
the transceiver’s capabilities, standard interfaces, manufacturer, and other information.
Additionally, Finisar SFP+ transceivers provide a enhanced digital diagnostic monitoring
interface, which allows real-time access to device operating parameters such as
transceiver temperature, laser bias current, transmitted optical power, received optical
power and transceiver supply voltage. It also defines a sophisticated system of alarm and
warning flags, which alerts end-users when particular operating parameters are outside of
a factory set normal range.
The SFP MSA defines a 256-byte memory map in E2PROM that is accessible over a
2-wire serial interface at the 8 bit address 1010000X (A0h). The digital diagnostic
monitoring interface makes use of the 8 bit address 1010001X (A2h), so the originally
defined serial ID memory map remains unchanged. The interface is identical to, and is
thus fully backward compatible with both the GBIC Specification and the SFP Multi
Source Agreement. The complete interface is described in Finisar Application Note AN2030: “Digital Diagnostics Monitoring Interface for SFP Optical Transceivers”.
The operating and diagnostics information is monitored and reported by a Digital
Diagnostics Transceiver Controller (DDTC) inside the transceiver, which is accessed
through a 2-wire serial interface. When the serial protocol is activated, the serial clock
signal (SCL, Mod Def 1) is generated by the host. The positive edge clocks data into the
SFP transceiver into those segments of the E2PROM that are not write-protected. The
negative edge clocks data from the SFP transceiver. The serial data signal (SDA, Mod
Def 2) is bi-directional for serial data transfer. The host uses SDA in conjunction with
SCL to mark the start and end of serial protocol activation. The memories are organized
as a series of 8-bit data words that can be addressed individually or sequentially.
For more information, please see the SFP MSA documentation
Note AN-2030.
Please note that evaluation board FDB-1018 is available with Finisar ModDEMO
software that allows simple to use communication over the 2-wire serial interface.
FTLX1471D3BCL Datacom SFP+ Product Specification – February 2009
X. Mechanical Specifications
Finisar FTLX1471D3BCL SFP+ transceivers are compatible with the SFF-8432
specification for improved pluggable form factor, and shown here for reference purposes
only. Bail color is blue.