Finicare FC IR101 User Manual

User manual
Operating Manual Infrared thermometer
Model: FC-IR101
1
CONTENTS
........................................................................................................................................................
1.1 Indications for Use
1.2 Safety Information
2. Principle
3. Product features
4. Technical parameters
5. Shape structure
6. Display icon definition
7. Function keys
8. Settings
9. Measuring method
9.1 Forehead temperature measurement
9.2 Ear temperature measurement
9.3 To be connected with your smart phone
10. Replacement of batteries
11. Cleaning and Maintenance
12.Trouble shooting
13. EMC Information
14. Commitment to quality and after-sales service
15. Manufacturer information
.........................................................................................................................................
.............................................................................................................................
.............................................................................................................................
...............................................................................................................................................
..................................................................................................................................
..........................................................................................................................
...................................................................................................................................
.........................................................................................................................
.......................................................................................................................................
................................................................................................................................................
..............................................................................................................................
........................................................................................................
..................................................................................................................
................................................................................................................
..............................................................................................................................
.............................................................................................................................
..............................................................................................................
..............................................................................................
..........................................................................................
.............................................................................
2 3 3 3 4 4 4 5 5 6 7 7 7 7 8 8
8 10 11 14 14
1. Introduction
FC-IR101 measures the body temperature through receiving the infrared energy radiation from the object of objects. It is with forehead temperature mode, and ear temperature mode. The measurement result directly shows on the LED screen. The device is widely used for home healthcare, medical institutes and many other occasions. The product is mainly composed with infrared temperature sensors, signal receiving processor, buttons, buzzer, LED display, battery, etc.
1.1 Indications for Use
The infrared thermometer is intended for the measurement and monitoring of human body temperature by doctor or customers in the hospital or home.
1.2 Safety Information
Warnings
Read the instruction manual before using this device.
The measurement results cannot replace the physician diagnosis.
The thermometer is placed in the position not touched by children.
Never point the device at ones’ eyes when measuring.
Do not try to change the product factory settings.
Use the thermometer in a stable temperature environment. Ifthe environment
temperature changes too much, for example from outdoor to indoor, please put the thermometer and wait for about half an hour minutes before measuring.
After measuring extremely high or low temperature, don’t measure body temperatures immediately, you should measure 10 minutes later.
Prohibit the thermometer into any liquid.
Don’t use in high or low temperature environment for a long time.
No collision, falling and sharp objects mix, it is forbidden to disassemble the
thermometer.
Don’t use in strong electromagnetic interference environment.
Avoid using the thermometer when drying the hair, drenching water, sweating, and
putting on skin cosmetics.
Don’t measure the temperature after doing sports, washing and 30 minutes before dinner.
Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the thermometer, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
No special maintenance is needed to the use process. Please contact the vendor or manufacturer for fault.
2. Principle
Any object in which temperature is higher than absolute zero degree will transmit some infrared radiation energy according to its own temperature. The radiation energy and its
distribution per wavelength are closely associated with its object temperature. Based on the principle, it is possible to measure the forehead object temperature and then adjust the offset between forehead temperature and actual body temperature, which will result in the correct display of body temperature.
3. Product features
Contact-type infrared measurement
Forehead, ear temperature, dual modes of measurement
High definition LED backlight, clearly and softly display;
Fever alarm function;
Capacity of storing 35 sets measurements
Switching between °C and °F
Auto shut-down and power-saving;
Switching between mute and un-mute mode
Can be connected with smart phone via Bluetooth 4.0.
4. Technical parameters
Table 1 Measurement method Measurement Mode Body Mode
Measurement accuracy
Contact-Type
32.0°C42.9°C89.6°F~109.2°F)
object Mode
Body Mode object Mode ±1.0°C/1.8°F
0°C100°C(32°F~212F) ±0.2°C/0.4°F
Display resolution 0.1°C/°F Operating environment
15° C ~ 35 ° C (59° F to 95 ° F)≦85% moisture condensation
Storage condition
-25°~55°C-(-13°Fto131°F)≦90% moisture condensation
Power supply DC1.5V×2 Power consumption
When off≦10 uw
power-off
When measuring≦30 mw
In 30 seconds
Weight About 70 g (without battery) Dimensions 160mm *39 mm *27.3mm(length x width x height) Product accessories 2x AAA batteries and 1x User Manual
Loading...