Finelite S12, 2E Installation Instructions Manual

Point A
Flat Endcap
Fixture
S12 LED Wall Mount 2E Starter/Independent Installation Instructions
Wall Stud
Hook Bracket
Mounting Bracket
Drywall
Screw
Fixture
Wall Stud
Top of Hook Bracket
Bottom of Hook Bracket
Drywall
Fixture
Po in t A
2.50"
4.50"
1.125"
0.0625"
Feed LocationJ-Box Location
Wall Stud
Mounting BracketPower Wire
J-Box
Screw
(by others)
Screw
(by others)
Rack Adjustment Screw
Bracket Cap
Step 1
Step 2
Determine feed location by measuring a horizonal line 4.5" from point A toward center of fixture, then 1.125" downward. Mark this spot for the feed. Centering J-box and install over feed location. Leave 8-10" of power wire exposed.
Step 3
Position mounting bracket so feed holes is aligned with J-box feed and pull wire leads through. Secure one side of mounting bracket to the wall. Using a level, secure opposite side of mounting bracket to wall. Secure mounting bracket to each wall stud. Use molly style fastener at ends if stud is not available.
© 2018 FINELITE, INC. ALL RIGHTS RESERVED. Form 98270. EFFECTIVE DATE: 12/07/18
Step 4
Holding fixture parallel to wall and slightly above bracket, slide fixture straight down to engage hooks on top and bottom of mounting bracket. Align end of fixture with end of bracket.
Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • 510 / 441-1100 • Fax: 510 / 441-1510 • www.finelite.com
Step 5
Check to ensure top and bottom of hook bracket are engaged in wall mounting bracket.
Step 6
Insert rack adjustment screw (provided) at each hook bracket location and thread into mounting bracket. tighten/release to raise of lower fixture. Place bracket cap on each exposed and of mounting bracket and ends of run.
Note: All power connections to be installed to
local/national codes by a Certified Electrician.
Point A
Flat Endcap
Starter
S12 LED Wall Mount 2E Joiner Installation Instructions
Wall Stud
Hook Bracket
Mounting Bracket
Drywall
Screw
Starter
Wall Stud
Top of Hook Bracket
Bottom of Hook Bracket
Drywall
Starter
Po in t A
2.50"
4.50"
1.125"
0.0625"
Feed LocationJ-Box Location
Wall Stud
Mounting BracketPower Wire
J-Box
Screw
(by others)
Screw
(by others)
Starter
Rack Adjustment Screw
Step 1
Step 2
Determine feed location by measuring a horizonal line 4.5" from point A toward center of fixture, then 1.125" downward. Mark this spot for the feed. Centering J-box and install over feed location. Leave 8-10" of power wire exposed.
Step 3
Position mounting bracket so feed holes is aligned with J-box feed and pull wire leads through. Secure one side of mounting bracket to the wall. Using a level, secure opposite side of mounting bracket to wall. Secure mounting bracket to each wall stud. Use molly style fastener at ends if stud is not available.
© 2018 FINELITE, INC. ALL RIGHTS RESERVED. Form 98271. EFFECTIVE DATE: 12/07/18
Step 4
Holding fixture parallel to wall and slightly above bracket, slide fixture straight down to engage hooks on top and bottom of mounting bracket. Align end of fixture with end of bracket.
Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • 510 / 441-1100 • Fax: 510 / 441-1510 • www.finelite.com
Step 5
Check to ensure top and bottom of hook bracket are engaged in wall mounting bracket.
Step 6
Insert rack adjustment screw (provided) at each hook bracket location and thread into mounting bracket. tighten/release to raise of lower fixture. Place bracket cap on each exposed and of mounting bracket and ends of run.
Note: All power connections to be installed to
local/national codes by a Certified Electrician.
S12 LED Wall Mount 2E Joiner Installation Instructions
Starter
Joiner/ender
Mounting Bracket
Plug Together Wiring
Joiner/Ender
Starter
Starter
Joiner/Ender
Joiner/Ender
Starter
#10-32 Screw (provided)
Lock Nut
#10-32 Screw (provided)
Lock Nut
Joiner/Ender
Rack Adjustment Screw
Starter
Step 7
Hold joiner/ender fixture up to wall. Connect plug together wiring
Step 10
Step 8
Slide joiner/ender to starter.
Step 9
Secure fixtures together with 2 joiner #10-32 screws and lock nuts (provided) to complete connection.
© 2018 FINELITE, INC. ALL RIGHTS RESERVED. Form 98271. EFFECTIVE DATE: 12/07/18
Insert one #8-32 rack adjustment screw (provided) on each side of joint/ender into mounting bracket. Tighten/loosen to level fixture. Turn power on to fixture.
Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • 510 / 441-1100 • Fax: 510 / 441-1510 • www.finelite.com
Note: All power connections to be installed to
local/national codes by a Certified Electrician.
Loading...