Finelite HP-4 Recessed, HP-4 Regressed Mounting And Feed Manual

HP-4 Recessed / Regressed
4"
5"
4"
4"
4-5/8"
4"
4"
4-5/8"
4-5/16"
4"
4-5/8"
4"
4"
5"
4"
4"
4-5/8"
4"
4"
6"
4"
4"
6"
4"
4"
6"
4-5/16"
4"
6"
4"
4"
4-7/8"
4"
4"
4-1/4"
4"
4"
6"
4"
1/16" For mudding and taping
3/8"
Mounting and Feed Guide
Recessed
Regressed
Customer:
1" T-Bar
(C1)
1" Tegular
(C1T)
Job: PO:
RECESSED MOUNTING OPTIONS
9/16" T-Bar
(C2)
9/16" Tegular
(C2T)
Standard Screw Slot
(C3)
Tech Zone 6"
(TZ6 C1)
Flush Screw Slot
(C3F)
Tech Zone 6"
(TZ6 C2)
Tech Zone 6"
(TZ6 C3)
Spackle Flange
(SF)
Version 1
Ceiling Option
VF
* Note: +/- 1/16"
Finelite, Inc. •30500 Whipple Road •Union City, CA 94587-1530 •510 / 441-1100 •FAX: 510 / 441-1510 •www.finelite.com
Tech Zone 6"
(TZ6 C3F)
Version 2
Ceiling Options
C1T, C2T, C3F, SF, TZ6
Tech Zone 6"
(TZ6 C2T)
© 2018 FINELITE, INC. ALL RIGHTS RESERVED CPG0043. V2 08/18
Visible Flange
(VF)
Version 3
Ceiling Options
C1, C2, C3
Page 1
HP-4 Recessed / Regressed
5"
1"
4"
4-1/4"
4"
1"
4-7/8"
5"
4"
1"
5"
5"
4"
1"
4-5/8"
5"
4"
1"
4-5/8"
5"
4"
1-5/16"
4-5/8"
5-5/16"
4"
1"
5"
5"
4"
1"
4-5/8"
5"
4"
1"
6"
5"
4"
1"
6"
5"
4"
1-5/16"
6"
5-5/16"
4"
1"
6"
5"
4"
1"
6"
5"
1/16" For mudding and taping
3/8"
Mounting and Feed Guide
REGRESSED MOUNTING OPTIONS
Recessed Regressed
1" T-Bar
(C1)
1" Tegular
(C1T)
Tech Zone 6"
(TZ6 C3)
9/16" T-Bar
(C2)
9/16" Tegular
(C2T)
Standard Screw Slot
(C3)
Tech Zone 6"
(TZ6 C1)
Flush Screw Slot
(C3F)
Tech Zone 6"
(TZ6 C2)
Tech Zone 6"
(TZ6 C3F)
Tech Zone 6"
(TZ6 C2T)
Spackle Flange
(SF)
Ceiling Option
* Note: +/- 1/16"
Version 1
VF
Finelite, Inc. •30500 Whipple Road •Union City, CA 94587-1530 •510 / 441-1100 •FAX: 510 / 441-1510 •www.finelite.com
Visible Flange
Version 2
Ceiling Options
C1T, C2T, C3F, SF, TZ6
(VF)
Version 3
Ceiling Options
C1, C2, C3
Page 2
© 2018 FINELITE, INC. ALL RIGHTS RESERVED CPG0043. V2 08/18
132" 96"
144"132"
36"
48"
84"
96"
84"
Starter
Starter
Starter
96"
96" 96"
96"
144"
144"
132"
144"
144"
96"
96"
94-7/8"
94-7/8"
46-7/8"
142-7/8"
142-7/8"
142-7/8"
144"
4'
8'
12'
16'
20'
24'
#8 Joiner Plate Screw Hole
1/4"-20 Threaded Rod Mounting Hole
1/4"-20 Threaded Rod Mounting Hole
Nominal Length
1-1/2"1-1/2"
#8 Joiner Plate Screw Hole
6" 6"
HP-4 Recessed / Regressed
Mounting and Feed Guide
Recessed Regressed
FEED OPTIONS
Conduit Plate - Front (Standard)
43704
Conduit Plate - Top
45086
Recessed T-Bar Luminaire Lengths (C1, C2, C3, C3F, C1T, C2T, TZ6)
Splice Box
89069
All starter/independent luminaires are 1-1/8" shorter than nominal. All joiner/ender luminaires are normal length.
Recessed Non-T-Bar Support Locations (VF, SF)
Finelite, Inc. •30500 Whipple Road •Union City, CA 94587-1530 •510 / 441-1100 •FAX: 510 / 441-1510 •www.finelite.com
© 2018 FINELITE, INC. ALL RIGHTS RESERVED CPG0043. V2 08/18
Note: Dimensions do not include endcaps.
12' MAXIMUM SECTION LENGTH.
Page 3
Loading...