Finelite 10WM series Joining Instructions

Read the Label
F o rm 9
8 0 6
6. 1
/
0 5
S i
d e
2
Look for the labels — you need them to install your job correctly.
Fixture Type and Run Length
Unique Fixture ID Number
Full Catalog Order ID
STARTER, JOINER, or ENDER
S5-20 STARTER ID: 1
S5-P-20-2T8-00000-EP-277-SC-MOT-FE-FW-00-00
ABC Corporation - A12495
Factory Order Number
UC
1. Identify all fixtures. Look for labels located:
2 labels - 1 at each end of box (or bag) 1 label - box top (or bag top) 1 on fixture (permanent)
2. Keep plastic bags ON for protection. T8 lamps may be turned on with the bags on. T5 and T5-HO lamps get too hot - remove bags before turning lamps on.
3. Lay out fixtures starting with ID: 1, then ID: 2, etc.
4. Hang STARTER fixture ID: 1. Secure both ends to mounting aircraft cable and level.
5. Hang far end of JOINER ID: 2 while supporting both ends.
6. Join ID: 1 and ID: 2 by attaching plug together wiring, screwing fixtures together.
NOTE: See additional mounting and joining instructions for each Finelite Series.
Hang fixtures in ID order. Hang prior to joining. Hang, Level, Join, repeat to the end of the run.
HANG PRIOR TO JOINING
STARTER ID:1 JOINER ID:2 JOINER ID:3 JOINER ID:4 ENDER ID:5
FINELITE
Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • 510 / 441-1100 • FAX: 510 / 441-1510 • www.finelite.com
JOINER Fixture
STARTER
Fixture
STARTER
Fixture
JOINER Fixture
FINELITE
Series 10 WM Joining Instructions
Finelite, Inc.◊30500 Whipple Road◊Union City, CA 94587-1530 ◊510 / 441-1100◊FAX: 510 / 441-1510◊www.finelite.com
98030.08/01
STEP 1.
Follow Finelite instructions to install STARTER fixture.
STEP 2.
Hold JOINER fixture up to wall. Connect plug-together wiring.
STEP 3. Slide JOINER into
STARTER fixture.
STEP 4.
Secure fixtures together with two joiner 10/32 screws (provided) to complete connection. FIGURE B.
STEP 5
. Secure JOINER fixture to wall studs as described in installation instructions.
FINAL CHECK-FIGURE B.
• Plug together wiring is connected.
• Two 10/32 screws have been installed between fixtures.
Repeat for remaining JOINER and ENDER fixtures to complete row.
STEP 1. Follow Finelite instructions to
install Mounting Bracket and STARTER.
STEP 2. Hold JOINER fixture up to wall.
Raise JOINER slightly above Mounting Bracket and holding fixture parallel to wall, slide fixture straight down to engage top and bottom edges in mounting bracket.
FIGURE A.
STEP 3. Connect plug-together wiring. Slide
JOINER into STARTER fixture.
STEP 4. Secure fixtures together with two
joiner 10/32 screws (provided) to complete connection. FIGURE B.
STEP 5
. Insert one 8/32 rack adjustment screw (provided) on each side of joint and thread into Mounting Bracket. Tighten /loosen to level fixture. FIGURE C.
FINAL CHECK-FIGURE C.
• Plug together wiring is connected.
• Two 10/32 screws have been installed between fixtures.
• Top and bottom of fixture and Mounting Bracket are correctly engaged. Rack adjustment 8/32 screws (inside) are secure.
Repeat for remaining JOINER and ENDER fixtures to complete row.
DO NOT ATTEMPT TO JOIN FIXTURES TOGETHER ON THE FLOOR. DAMAGE MAY RESULT WHEN LIFTED. FOLLOW THESE INSTRUCTIONS.
FIGURE A.
FIGURE B.
T
E
K
C
A
R
B
G
NITN
U
OM
T
NU
O
M
E
CAFRUS
plug together wiring
Push interlocking joiners together. Secure with 10/32 joiner screws.
Joint secured with 10/32 joiner screws (provided).
STARTER
Fixture
JOINER
Fixture
JOINER
Fixture
STARTER
Fixture
STARTER
Fixture
JOINER Fixture
Push Joiner parallel to wall then down to catch top and bottom of fixture into wall bracket.
Slide
plug together wiring
Joint secured with 10/32 joiner screws (provided).
Fixture must be secure on top and bottom of wall Mounting Bracket
Rack adjustment 8/32 screws (inside) for leveling.
Mounting Bracket
wall
wall
Fixture
FIGURE A.
FIGURE B.
FIGURE C.
FINELITE
INSTRUCTIONS
1. Position fixture on wall in desired location. Mark on wall the point where the endcap and the fixture body meet. This is Point A. Remove fixture.
2. Determine feed location by measuring a horizontal line 4.5from Point A toward center of fixture, then 1.75″downward. Mark this spot for feed.
3. Install 4x2
J-Box centering box over feed location and align top of box with Point A. Leave 8-10of power wire exposed.
4a. Measure a horizontal line from Point A to
the opposite end of the fixture (or run) and mark the wall at the center of each stud and at the end of the fixture (or run). This marks the top of the fixture (or run).
4b. At each support location that is not secured
into a stud (usually ends) drill hole 1.25 down from top of fixture. Use a molly style fastener at end(s) if stud is not available.
5. Remove reflector and lamps. Position fixture on wall level with marks made in Step 4a. Secure to wall at each end and at each stud.
6. Make splice in feed, reinstall reflector and lamps.
Series 10WM Instructions - Surface Mount
98028.08/01
Finelite, Inc.
30500 Whipple Road◊Union City, CA 94587-1530
510 / 441-1100
FAX: 510 / 441-1510
www.finelite.com◊Better Lighting For A Better Workplace
Series 10 Wall Mount Installation Instructions - Surface Mount
A
A
4.5"
1.75"
2.5"
2.5"
A
1.
3.
2.
4.
6.
5.
Mark the wall at Point A.
Fixture Body
Endcap
Determine feed location
Install J-Box
Standard
4
x2″J-Box
Feed Location
Make power splice. Replace reflector and lamps.
Screw securing fixture to wall.
Feed Hole
Remove lamps and reflector. Secure to wall at each stud and at each fixture end.
x
x
x
fixture
stud
stud
stud
stud
stud
stud
stud
stud
fixture
Stud
= Mounting locations requiring molly style
wall fastener
= Mounting locations at studs
Secure at each stud.
Mounting Holes
= Distance between studs
x
Loading...