READ ALL INSTRUCTIONS BEFORE UNPACKING THE PRODUCT
INSTRUCTIONS THAT, IF IGNORED COULD RESULT IN DEATH OR SERIOUS INJURY CAUSED BY INCORRECT HANDLING
OR INSTALLATION OF THE PRODUCT. THESE INSTRUCTIONS MUST BE OBSERVED FOR SAFE INSTALLATION.
2 PEOPLE ARE REQUIRED TO LIFT AND DURING
ENTIRE INSTALLATION OF THIS PRODUCT
INSTALLATION OF THIS PRODUCTS BY AN
INEXPERIENCED INSTALLER MAY RESULT
PERSONAL INJURY OR DEATH!
We reserves the right to change, update, modify, alter, redesign this manual/product or its policies without prior notice!
It is your responsibility to visit website to download or contact customer service for the most updated version of the installation instructions.
206 wembly Road.
Phone: 7 18.602.60 60
Fax: 7 18.963.20 82
We shall not be liable for any injuries or property damages in connection with this product during installation or use of this product!
This products must be installed by a fully insured and licensed plumber only. Installation of any our product by anyone other than fully insured and
licensed plumber shall void limited warranty. We recommends that such licensed plumber have experience in the installation of products.
Limited warranty is void on any commercial installation.
We are not responsible for local code compliance for this product. Building and plumbing codes may vary from state-to-state in accordance to your
location. We are not resonsible for providing any compliance certifications.
We are not responsible to provide any type of certifications for this product.
Under no circumstances we are shall not be liable for any and all incidental damages sustained in connection with this product Neither manufacture,
nor distributor, nor retailer is responsible for water damage or flood caused due to use of this product.
Under no circumstances We shall not be liable for any and all fees, cost of installation/reinstallation/removal, subsequent damage or transportation in
case of the product defect.
TOOLS REQUIRED FOR INSTALLATIONTOILET COMPONENTS
During unpacking the product and prior to installation
inspect your new product for any damages or missing parts.
Do not attempt to install or operate the product if the
You may connect the water supply line using two different
options. In both options distance from the floor to the
center of the supply line must be 5 1/2". In Supply
Position 1, the water supply is located behind the toilet
and is offset by 4 1/2" from the installed toilet's center. In
supply Position 2 the water supply line must offset by 10"
from the center of the installed toilet.
Position 1
Supply
Position 2
5 1/2"
Wall
5 1/2"
5 1/2"
ATTENTION! Dimensions may vary by up to 3/8". It is highly recommended to pull
TECHNICAL DATA
• Dual ush: 1/1.6 GPF
3
Tank Top View (Inside)
Rough-in
12"
Standard
Floor
Half
Flush
(1GPF)
Full
Flush
(1.6GPF)
Flush GPF amount is factory
set. No additional adjustment
is required.
Half
Flush
(1GPF)
all dimensions of actual model for installation and measuring purposes.
Adjust the water level in the
toilet's tank if neccessary by
rotating the adjustment screw
to increase (+) or decrease
(-) a level of water in the
toilet's tank.
F O R A LIFE O F ST YLE
TM
Page 5
INSTALLATION INSTRUCTIONS
IMPORTANT!
Shut o main water supply prior to installation!
REMOVE OLD TOILET
1. Shut off water supply line. If you do not have shut-off valve near the toilet shut off main water supply line.
2. Flush the old toilet and make sure that tank is empty.
3. Disconnect and remove water supply line connected to the toilet's tank.
4. Remove old toilet, bolts, nuts from the closet flange.
5. Clean closet flange area from old wax ring and putty sealant using putty knife from the base area.
6. Clean any remaining debris and wipe any water at the installation area
7. Temporarily plug flange on a floor with a flange plug or towel to prevent gasses from escaping
IMPORTANT! The mounting surface
area must be clean, dry, and leveled
prior to installation of the new toilet!
NOTE! Inspect the existing closet ange for
damages. If damaged, replace it to new
ange before proceeding to the installation
PREPARE CLOSET FLANGE
Make sure that rough-in is 12" by measuring the
distance from the wall to the center of the
closet ange.
See Figure 1
Bathroom
Wall
Bathroom
Floor
Step 1. Insert 2 oor bolts inside of the toilet
ange Step 2. Slide the closet bolts through the
holes and align bolts horizontaly.
See Figure 2
Step 1Step 2
12"
Rough-in
Closet Flange
Figure 1Figure 2
90º
90º
INSTALL WAX RING
Important: safety glasses must be worn by the installer and all bystanders.
Cover the oor with a soft-close blanket. Carefully turn the toilet on it's
side or upside-down on the blanket with assistance of a second person.
Install wax ring over the horn discharge located on the bottom of the
toilet's bowl.
See Figure 3
Note: Ceramic is a fragile material. You must always cover the oor with a
soft-cloth blanket if you want to put the toilet on the oor on any side
other than the bottom of the toilet. If you do not cover the oor with a
soft-close blanket contact of the toilet with the oor may and will cause
minor or moderate scratches on the toilet's surface.
Always Use Soft-Cloth Blanket
4
Prior to installtion the
wax ring must be kept
in a room temperature
between 70-75ºF.
Step 1. Lift and carefully put the toilet over the closet ange so the
closet bolts can go through the mounting holes in the toilet's base.
Once the bowl is in the position press the bowl down with slight
twisting motion in level position towards the oor. Apply your body
weight to evenly compress the wax ring to create watertight seal.
Make sure that the bowl is as leveled as possible to have a nice seal
tight.
Do not rock the toilet back and forth and side to side as it may and
will break a seal and you will need to replace the wax ring again and
start the installation process over.
See Figure 4
Step 2. Once the toilet is set and leveled install washers and nuts
over the closet bolts. Tighten nuts. Do not overtighten the nuts. It
may and will cause damage to the toilet's ceramic base.
See Figure 5
CONNECT TOILET'S TANK
TO WATER SUPPLY LINE
2 PEOPLE ARE REQUIRED TO LIFT AND DURING
ENTIRE INSTALLATION OF THIS PRODUCT
Wall
Note: It may be required to use shims under
the edge of the toilet's bowl. Due to
manufacturing process of vitreous china
ceramic products, every toilet may have
slight level variations. It does not mean that
the toilet is defective. In addition your oor
might be uneven or not leveled as well.
Floor
Figure 4
Connect the water supply line between the tank and water
shut-o valve using a toilet hose (not supplied). When connecting
toilet hose tighten coupling nut to the tank by 1/4 turn beyond the
hand tight.
Do not overtighten nut on the tank connection. It may and will cause water leakage.
Turn on valve on water supply line and allow tank to ll. Check all
connections for leakages and tighten as needed.
Once tank is lled with water ush it 4-5 times to perform a test of
the ushing system. At the same time check the bottom of the
toilet for leaks to make sure that the wax ring is properly installed
and sealed.
If there are no leaks you are ready nalize the installion. If any
shims are installed at the bottom of the toilet's bowl you may trim
them. Apply silicone around base of the toilet's. Allow 24 hours for
silicone to dry before start using the toilet. See Figure 6
Important: Leaks may not occur during or right after the installation. Make sure to check for leaks every couple hours rst day
installed and and occasionally check it everyday for the next week
to ensure that toilet is properly installed and no leaks occur. If any
leaks occur immediately shut o the water supply line valve and
contact your local plumber to x all leaks.
Important:
Under no circumstances We shall not be liable for any and all
incidental damages sustained in connection with this product
Neither manufacture, nor distributor, nor retailer is responsible for
water damage or ood caused due to use of this product.
Under no circumstances We shall not be liable for any and all fees,
cost of installation/reinstallation/removal, subsequent damage or
transportation in case of the product defect
Important Note: Flush GPF amount is factory set. No additional adjustment is required. This page is for reference only.
95mm
Max 19.5mm - Min 8.5mm
IMPORTANT: Do not use or drop any chlorine or any other chemicals. Use of chemical products will result in damage to
the ll valve and ush valve components and may cause ood and property damage. Do not overtighten bolts/nuts as it
may and will cause damage to the toilet parts and componets.
1. PREPARATION
58mm
WL
Max 289mm, Min 189mm
(Max 344mm, Min 244 mm)
Max 230mm, Min 90mm
(Max 285mm, Min 145 mm)
All adjustments are already made by manufacturer.
C.L.
45mm
Instructions:
When valve installed, the critical level
mark on ll valve (identied by C.L.
mark on valve body) shoud be at least 1"
above top of the over ow pipe.
Required:
• Water temperature: 36-112ºF
Important:
Under no circumstances seller shall not be liable for any
and all incidental damages sustained in connection with
this product
Neither manufacture, nor distributor, nor retailer is
responsible for water damage or ood caused due to
use of this product.
Under no circumstances seller shall not be liable for any
and all fees, cost of installation/reinstallation/removal,
subsequent damage or transportation in case of the
product defect
Remove the worn-out ttings and clean your tank prior to the installation of the new ones. There might be a lot of impurities in your
tank that may cause damage to the new parts if you do not clean them out. The tank must be absolutely clean prior to installation.
2. WATER LEVEL ADJUSTMENT
Solution 2
Rotate screw to adjust
desired water level
Rotating screw, rise or lower the water
level to adjust water level to suitable
position (water volume will gradually
increase when the adjuster is moved
upward from the bottom.)
Check the ll valve and
make sure that it does
not have any damaged
or missing parts
Solution 1
Press and
unscrew
Pull upwards
press down to
desired height
1. Press buckle and unscrew.
2. Pull the valve upwards or press down to desired
height.
3. Unscrew the valve body and fasten the buckle
Unscrew
clockwise
and fasten
valves
3. FILL VALVE INSTALLATION
Install the valve into tank. Do
not use any wrench tools.
Fasten with hand only.
8
Connect water supply to the
ll valve. Turn on water.
Turn o water supply valve
before height adjustment of
the toilet's ll valve.
Put the rell tube into the
white cap hole rmly.
F O R A LIFE O F ST YLE
TM
Page 10
CLEANING & TROUBLESHOOTING (FILL VALVE)
FILL VALVE CLEANING
206 wembly Road.
New Windsor, NY 12553
Phone: 7 18.602.60 60
Fax: 7 18.963.20 82
info@nextures.com
www.nextures.com
Shut o water supply line
before lter cleaning.
Carefully, take out the lter
from inlet by using pliers.
Use water to wash and clean
the lter and adapter from
any debris.
Re-install the lter and
re-connect the water supply
line.
TROUBLESHOOTING
IssueCauseSolutionSolution #4
Water level is too high
or too low
Fill valve fails to shut o
or fails to ll the water
into the toilet's tank
Improper water level
adjustment
1. Inlet valve switch is
turned on.
2. Inlet valve oat crashed
against ceramic wall
3. Filter screen is clogged
due to dirty water
4. Improper rell hose
installation
Adjust the water level
1. Turn on inlet valve switch
2. Adjust inlet valve position
3. Clean the lter screen
4. Install rell hose correctly
(see diagram on the right)
Water
Level
MAINTENANCE & CARE
Use soft sponges or soft-cloths to clean the surface. Always rinse thoroughly any cleaning solutions immediately after
cleaning. Do not any chemical remain on the surface for extended periods of time.
IMPORTANT!
RIGHTWRONG
DO NOT USE: Abrasive cleaners such as: acid, ammonia, bleach, and simmilar solutions. Use of such solutions may cause
corrosion, nish peeling, and/or dull the surface.
DO NOT USE: Abrasive sponges or cloth. Never use steel, wool, or wired brushes that will permanently scratch the surface.
FILL/FLUSH VALVES MAINTENANCE & CARE
Do not pour any mounts of chlorine or any other chemicals into the tank. Use of chemical products will result in damage to the ll
valve and ush valve components and may cause ood and property damage
Note: ll and ush valves are maintenance free. No maintenance is required.
Retain these installation instructions for future reference!
Thank you for using Fine Fixtures!
9
F O R A LIFE O F ST YLE
TM
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.