2 CO (DPDT) 3 CO (3PDT)
2 NO (DPST-NO), ≥3 mm*
3 NO (3PST-NO), ≥3 mm*
16/30** 16/30**
250/400 250/400
4,000 4,000
750 750
0.8/— 0.8/1.5 0.8/— 0.8/1.5
16/0.6/0.4 16/1.1/0.7
1,000 (10/10) 1,000 (10/10)
AgCdO AgCdO
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2.2/1.3 3/3
(0.8…1.1)U
N
(0.85…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 UN/0.6 U
N
0.8 UN/0.6 U
N
0.2 UN/0.1 U
N
0.2 UN/0.1 U
N
10 · 106/30 · 10
6
10 · 106/30 · 10
6
100 · 10
3
100 · 10
3
10/10 20/4
66
1,500 2,500
–40…+70 –40…+50
RT I RT I
2 & 3 pole changeover contact
PCB mount
2 & 3 pole normally open contact
(
3 mm contact gap)
PCB mount
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Motor rating (230/400 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (U
N
) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Holding voltage AC/DC
Must drop-out voltage AC/DC
Technical data
Mechanical life AC/DC cycles
Electrical life at rated load AC1 cycles
Operate/release time ms
Insulation between coil and contacts (1.2/50 µs)
kV
Dielectric strength between open contacts V AC
Ambient temperature range °C
Environmental protection
Approvals (according to type)
62.22 62.23 62.22 - 0300 62.23 - 0300
Copper side view Copper side view Copper side view Copper side view
* Distance between contacts 3 mm
(EN 60730-1).
** With the AgSnO
2
material the
maximum
peak
current is 120 A - 5 ms (NO contact).
FORUL H
ORSEPOWER ANDPILOTDUTY RATINGS
SEE“General technical information” page
V
62.22 / 62.23 62.22-0300 / 62.23-0300
1
Features
Printed circuit mount 16 A Power relay
2 & 3 Pole changeover contacts or NO
(3 mm contact gap)
AC coils & DC coils
Reinforced insulation between coil and
contacts according to EN 60335-1, with 6 mm clearance & 8 mm creepage distance
SELV coil-contact separator option
Cadmium Free contact material options
62.23
62.2x-0300
8
8
38.2
22.2
62.22
62 Series - Power relays 16 A
35.8
45.6
3.5
8
8.65
7.6 8.3
3.5
9.7
5.5 5.75
8
38.2
11.1
8.65
35.8
7.6 8.3
12 14 32 34
1
4
45.6
9.7
11.25
11 31
7
AB
A1 A2
38.2
22.28
13
12
32
4 6
14
34
79
11
35.8 2
31
AB
A2A1
36
9
8
12 14 22 24 32 34
A1 A2
5.6
5.8 8
35.8
7.6
8.8
4
1
25836
11 21 31
7
AB
38.2
11.1
11.18
13
12
22
4 6
14
24
79
11
21
2
AB
8
32
34
31
A2A1
14 34
4
11 31
9
5.6
5.8 8
7.6
8.8
7
AB
A1 A2
4 6
14
79
11
35.8 2
AB
9
38.2 8
22.28
34
31
A2A1
6
11.4
8
7.6
8.8
14 24 34
4
586
11 21 31
7
AB
A1 A2
38.2
11.1
11.18
4 6
1411242134
31
79
35.8 2
AB
A2A1
9
8
11.4
8
7.6
8.8
2 CO (DPDT) 3 CO (3PDT)
2 NO (DPST-NO), ≥3 mm*
3 NO (3PST-NO), ≥3 mm*
16/30** 16/30**
250/400 250/400
4,000 4,000
750 750
0.8/— 0.8/1.5 0.8/— 0.8/1.5
16/0.6/0.4 16/1.1/0.7
1,000 (10/10) 1,000 (10/10)
AgCdO AgCdO
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2.2/1.3 3/3
(0.8…1.1)U
N
(0.85…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 UN/0.6 U
N
0.8 UN/0.6 U
N
0.2 UN/0.1 U
N
0.2 UN/0.1 U
N
10 · 106/30 · 10
6
10 · 106/30 · 10
6
100 · 10
3
100 · 10
3
10/10 20/4
66
1,500 2,500
–40…+70 –40…+50
RT I RT I
2 & 3 pole changeover contact
Plug-in / Faston 187
2 & 3 pole normally open contact
(3 mm contact gap)
Plug-in / Faston 187
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Motor rating (230/400 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (U
N
) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Holding voltage AC/DC
Must drop-out voltage AC/DC
Technical data
Mechanical life AC/DC cycles
Electrical life at rated load AC1 cycles
Operate/release time ms
Insulation between coil and contacts (1.2/50 µs)
kV
Dielectric strength between open contacts V AC
Ambient temperature range °C
Environmental protection
Approvals (according to type)
* Distance between contacts 3 mm
(EN 60730-1).
** With the AgSnO
2
material the
maximum
peak
current is 120 A - 5 ms (NO contact).
FORUL H
ORSEPOWER ANDPILOTDUTY RATINGS
SEE“General technical information” page
V
62.32 / 62.33 62.32-0300 / 62.33-0300
Features
Plug-in mount/Faston 187 16 A Power relay
Plug-in (92 series sockets) or Faston 187
(4.8x0.5 mm) with optional mounting adaptors
2 & 3 Pole changeover contacts or NO
(3 mm contact gap)
AC coils & DC coils
UL Listing (certain relay/socket combinations)
LED, mechanical indicator & test button options
Reinforced insulation between coil and
contacts according to EN 60335-1, with 6 mm clearance & 8 mm creepage distance
SELV coil-contact separator option
Cadmium Free contact material options
Sockets and accessories
62 Series - Power relays 16 A
88
38.2
22.2
1
7
AB
4
A1 A2
36
9
12 14 32 34
11 31
62.32 62.33
62.32 62.33
62.32-0300 62.33-0300
62.320-00 62.33-0300
2
12 14 22 24 32 34
1
4
25836
11 21 31
7
AB
A1 A2
9
14 34 4
11 31
7
AB
A1 A2
9
6
38.2
8
11.1
35.8
47.6
3.5
8
8.65
7.6 8.35.5 5.75
9.7
38.2
22.2
8
88
14 24 34
4
586
11 21 31
7
AB
A1 A2
38.2
11.1
35.8
3.5
8
8.65
7.6 8.3
11.25
9
45.6
9.7
62.82 62.83
2 CO (DPDT) 3 CO (3PDT)
2 NO (DPST-NO), ≥3 mm* 3 NO (3PST-NO), ≥3 mm*
16/30** 16/30**
250/400 250/400
4,000 4,000
750 750
0.8/— 0.8/1.5 0.8/— 0.8/1.5
16/0.6/0.4 16/1.1/0.7
1,000 (10/10) 1,000 (10/10)
AgCdO AgCdO
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2.2/1.3 3/3
(0.8…1.1)U
N
(0.85…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 UN/0.6 U
N
0.8 UN/0.6 U
N
0.2 UN/0.1 U
N
0.2 UN/0.1 U
N
10 · 106/30 · 10
6
10 · 106/30 · 10
6
100 · 10
3
100 · 10
3
10/10 20/4
66
1,500 2,500
–40…+70 –40…+50
RT I RT I
2 & 3 pole changeover contact
Flange mount / Faston 250
2 & 3 pole normally open contact
(3 mm contact gap)
Flange mount / Faston 250
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Motor rating (230/400 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (U
N
) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Holding voltage AC/DC
Must drop-out voltage AC/DC
Technical data
Mechanical life AC/DC cycles
Electrical life at rated load AC1 cycles
Operate/release time ms
Insulation between coil and contacts (1.2/50 µs)
kV
Dielectric strength between open contacts V AC
Ambient temperature range °C
Environmental protection
Approvals (according to type)
* Distance between contacts 3 mm
(EN 60730-1).
** With the AgSnO
2
material the
maximum
peak
current is 120 A - 5 ms (NO contact).
FORUL H
ORSEPOWER ANDPILOTDUTY RATINGS
SEE“General technical information” page
V
62.82 / 62.83 62.82-0300 / 62.83-0300
Features
Flange mount/Faston 250 16 A Power relay
Faston 250 (6.3x0.8 mm) termination Flange
or optional mounting adaptors
2 & 3 Pole changeover contacts or NO
(3 mm contact gap)
AC coils & DC coils
LED, mechanical indicator & test button options
Reinforced insulation between coil and
contacts according to EN 60335-1, with 6 mm clearance & 8 mm creepage distance
SELV coil-contact separator option
Cadmium Free contact material options
62 Series - Power relays 16 A
62.82
62.83
62.82-0300
62.82-0300
7
AB
4
A1 A2
6
9
14 34
11 31
88 22.2
63
68
38.2
3.6
62.83-0300
62.83-0300
3
12 14 32 34
1
4
36
11 31
7
AB
A1 A2
38.2
3.6
63
68
88
22.2
12 14 22 24 32 34
1
4
25836
11 21 31
9
7
AB
A1 A2
9
38.2
11.1
3.6
8
35.8
7.688
5.8 5.6
47.6
9.7
63
68
8.8
14 24 34
4
11 21 31
7
A1 A2
38.2
3.6
63
88
11.1
586
9
AB
35.8
68
8.8 7.6811.4
45.6
9.7
Loading...
+ 7 hidden pages