FINDER 60.12.8.060.0040, 60.12.8.048.0040, 60.12.8.024.0040, 60.12.8.012.0040, 60.12.8.110.0040 Specification

...
Page 1
60
2 CO (DPDT) 3 CO (3PDT)
10/20 10/20
250/400 250/400
2,500 2,500
500 500
0.37 0.37
10/0.4/0.15 10/0.4/0.15
500 (10/5) 500 (10/5)
AgNi AgNi
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
2.2/1.3 2.2/1.3
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 UN/0.5 U
N
0.8 UN/0.5 U
N
0.2 UN/0.1 U
N
0.2 UN/0.1 U
N
20 · 106/50 · 10
6
20 · 106/50 · 10
6
200 · 10
3
200 · 10
3
9/9 9/9
3.6 3.6
1,000 1,000
–40…+70 –40…+70
RT I RT I
2 pole - 10 A power contacts
8 pin plug-in
3 pole - 10 A power contacts
11 pin plug-in
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Single phase motor rating (230 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (U
N
) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Holding voltage AC/DC
Must drop-out voltage AC/DC
Technical data
Mechanical life AC/DC cycles
Electrical life at rated load AC1 cycles
Operate/release time ms
Insulation between coil and contacts (1.2/50 µs)
kV
Dielectric strength between open contacts V AC
Ambient temperature range °C
Environmental protection
Approvals (according to type)
83
60.12 60.13
Features
Plug-in mount 10 A General purpose relay
2 & 3 pole changeover contacts
Cadmium Free contacts
(preferred version)
AC coils & DC coils
UL Listed (certain relay/socket
combinations)
Contact material options
Lockable test button with mechanical flag
indicator (preferred version)
90 series sockets, coil EMC suppression
and timer accessories
60 Series - General purpose relays 6 - 10 A
124 225
143 246
111 218
A12 A27
32.5
36.4
124 328
143 111 3111
A12 A210
32.5
36.4
349
54.2
12.6
54.2
12.6
Page 2
2 CO (DPDT) 3 CO (3PDT)
6/10 6/10
250/400 250/400
1,500 1,500
250 250
0.185 0.185
6/0.3/0.12 6/0.3/0.12
50 (5/5) 50 (5/5)
AgNi + Au bifurcated contacts AgNi + Au bifurcated contacts
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
2.2/1.3 2.2/1.3
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 UN/0.5 U
N
0.8 UN/0.5 U
N
0.2 UN/0.1 U
N
0.2 UN/0.1 U
N
20 · 106/50 · 10
6
20 · 106/50 · 10
6
250 · 10
3
250 · 10
3
9/9 9/9
3.6 3.6
1,000 1,000
–40…+70 –40…+70
RT I RT I
2 pole - 6 A bifurcated contacts
8 pin plug-in
3 pole - 6 A bifurcated contacts
11 pin plug-in
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Single phase motor rating (230 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (U
N
) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Holding voltage AC/DC
Must drop-out voltage AC/DC
Technical data
Mechanical life AC/DC cycles
Electrical life at rated load AC1 cycles
Operate/release time ms
Insulation between coil and contacts (1.2/50 µs)
kV
Dielectric strength between open contacts V AC
Ambient temperature range °C
Environmental protection
Approvals (according to type)
60.12 - 0200 60.13 - 0200
Features
Plug-in mount - 6 A Bifurcated contacts for low level switching
2 & 3 pole changeover contacts
Cadmium Free contacts
(Gold plated Silver Nickel)
AC coils & DC coils
Lockable test button with mechanical flag
indicator (preferred version)
90 series sockets, coil EMC suppression
and timer accessories
60 Series - General purpose relays 6 - 10 A
84
60
124 225
143 246
111 218
A12 A27
32.5
36.4
124 328
143 111 3111
A12 A210
32.5
349
36.4
54.2
12.6
54.2
12.6
Page 3
60
2 CO (DPDT) 3 CO (3PDT)
10/20 10/20
250/400 250/400
2,500 2,500
500 500
0.37 0.37
10/0.4/0.15 10/0.4/0.15
500 (10/5) 500 (10/5)
AgNi AgNi
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
2.2/1.3 2.2/1.3
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 UN/0.5 U
N
0.8 UN/0.5 U
N
0.2 UN/0.1 U
N
0.2 UN/0.1 U
N
20 · 106/50 · 10
6
20 · 106/50 · 10
6
200 · 10
3
200 · 10
3
9/9 9/9
3.6 3.6
1,000 1,000
–40…+70 –40…+70
RT I RT I
2 pole - 10 A power contacts
Flange mount/Faston 187
3 pole - 10 A power contacts
Flange mount/Faston 187
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Single phase motor rating (230 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (U
N
) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Holding voltage AC/DC
Must drop-out voltage AC/DC
Technical data
Mechanical life AC/DC cycles
Electrical life at rated load AC1 cycles
Operate/release time ms
Insulation between coil and contacts (1.2/50 µs)
kV
Dielectric strength between open contacts V AC
Ambient temperature range °C
Environmental protection
Approvals (according to type)
85
60.62 60.63
Features
Flange mount 10 A General purpose relay
Flange mount (Faston 187,
4.8x0.8 mm termination)
2 & 3 pole changeover contacts
AC coils & DC coils
Cadmium Free contacts
(preferred version)
Contacts material options
60 Series - General purpose relays 6 - 10 A
1
4
36
7
9
AB
A1 A2
32.2
3.6
52
36.5
1
4
25836
7
9
AB
A1 A2
32.2
3.6
43
52
36.5
43
7
187.1 7.1
1195.9 6.2 4.4
187.1 7.1
7
1195.9 6.2 4.4
Page 4
86
Ordering information
2
7/10
A1 A2
2
A1
A2
7/10
C: Option 3, 5, 54
LED (AC)
C: Option 6, 7, 74
LED + diode (DC, polarity positive to pin 2)
Lockable test button and
mechanical flag indicator (0040)
The dual-purpose Finder test button can be used in two ways: Case 1
) The plastic pip (located directly above the test button) remains intact. In this case, when the test button is pushed, the contacts operate. When the test button is released the contacts return to their former state.
Case 2)
The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to the above function), when the test button is pushed and rotated, the contacts are latched in the operating state, and remain so until the test button is rotated back to its former position.
In both cases ensure that the test button actuation is swift and decisive.
Example: 60 series plug-in relay, 3 CO (3PDT), 12 V DC coil, test button and mechanical indicator.
A: Contact material
0 = Standard 2 = AgCdO 5 = AgNi + Au (5 µm)
B: Contact circuit
0 = CO (nPDT) 2 = Bifurcated contacts
60.12/13 - 6 A only
Series
Type
1 = 8/11 pin plug-in 6 = Faston 187 (4.8x0.8 mm)
with flange mount
No. of poles
2 = 2 pole 3 = 3 pole
Coil version
4 = Current sensing 8 = AC (50/60 Hz) 9 = DC
Coil voltage
see coil specifications
1 3 0 09
D: Special versions
0 = Standard
C: Options
0 = None 2 = Mechanical indicator 3 = LED (AC) 4 = Lockable test button +
mechanical indicator 5 = Lockable test button + LED (AC) 54 = Lockable test button + LED (AC) +
mechanical indicator 6 = LED + diode (DC, polarity positive
to pin 2) 7 = Lockable test button + LED + diode
(DC, polarity positive to pin 2) 74 = Lockable test button + LED + diode
(DC, polarity positive to pin 2) +
mechanical indicator
4 0
ABCD
... .
01260
Type Coil version A B C D
60.12/13 AC 0 - 2 0 0
- 2 - 3 - 4 - 5
0
AC 0 - 2 0 54 / AC 5 0 - 2 0
- 2 - 3 - 4 - 5
0 AC 5 0 - 2 54 / DC 0 - 2 0 0
- 2 - 4- 6 - 7
0
DC 0 - 2 0 74 / DC 5 0 - 2 0
- 2 - 4 - 6 - 7
0 DC 5 0 - 2 74 / current sensing 0 0 4 0
60.62/63 AC-DC 0 - 2 - 5 00 0
60 Series - General purpose relays 6 - 10 A
Selecting features and options: only combinations in the same row are possible. Preferred selections for best avaliability are shown in bold.
Descriptions: Options and Special versions
60
Page 5
60
87
60 Series - General purpose relays 6 - 10 A
Technical data
Contact specification
F 60 - Electrical life (AC) v contact current
Cycles
H 60 - Maximum DC1 breaking capacity
DC voltage (V)
DC breaking current (A)
contacts in series
Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4
When switching a resistive load (DC1) having voltage and current
values under the curve, an electrical life of ≥ 100·103can be expected.
In the case of DC13 loads, the connection of a diode in parallel with
the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased.
Nominal Coil Operating range Resistance Rated coil
voltage code
consumption
U
N
U
min
U
max
R
I at UN(50Hz)
VVV mA
6 8.006 4.8 6.6 4.6 367 12 8.012 9.6 13.2 19 183 24 8.024 19.2 26.4 74 90 48 8.048 38.4 52.8 290 47 60 8.060 48 66 450 37
110 8.110 88 121 1,600 20 120 8.120 96 132 1,940 18.6 230 8.230 184 253 7,250 10.5 240 8.240 192 264 8,500 9.2 400 8.400 320 440 19,800 6
Nominal Coil Operating range Resistance Rated coil
voltage code
consumption
U
N
U
min
U
max
R I at U
N
VVV mA
6 9.006 4.8 6.6 28 214 12 9.012 9.6 13.2 110 109 24 9.024 19.2 26.4 445 53.9 48 9.048 38.4 52.8 1,770 27.1 60 9.060 48 66 2,760 21.7
110 9.110 88 121 9,420 11.7 125 9.125 100 137.5 12,000 10.4 220 9.220 176 242 37,300 5.8
AC coil data
DC coil data
Coil specifications
Insulation
Insulation according to EN 61810-1 ed. 2 insulation rated voltage V 250 400
rated impulse withstand voltage kV 4 (2 pole) 3.6 (3 pole) 4 (2 pole) 3.6 (3 pole) pollution degree 3 2
overvoltage category III III Insulation between coil and contacts (1.2/50 µs) kV 3.6 Dielectric strength between open contacts V AC 1,000 Dielectric strength between adjacent contacts V AC 2,000
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2 EN 61000-4-4 level 4 (4 kV) Surge (1.2/50 µs) on A1 - A2 (differential mode) EN 61000-4-5 level 4 (4 kV)
Other data
Bounce time: NO/NC ms 2/4 Vibration resistance (5…55)Hz, max. ± 1 mm: NO/NC g/g 22/22 Shock resistance g 20 Power lost to the environment 2 pole 3 pole
without contact current W 1.3 1.3
with rated current W 2.7 3.4
7
10
10
10
6
5
8
1240
16 (A)
20
10
6 4
2
1
0.2
0.1
20 60
2
1
3
100 140 180 220
Page 6
(°C)
6030 50
2.0
10-20
1.0
0.5
1.5
0407020-10
U U
N
80
2
1
88
1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature.
Typical application with current sensing relays. An open circuit filiment of lamp L
1 is detected by the current sensing
relay coil (K1) which causes the back-up safety lamp L2 to be energised, and indication of failure at the control panel via lamp S1. Example: navigation light. L
1 = Light
L2 = Safety light S1 = Control light K
1 = Relay
Coil specifications
Current sensing version
1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature.
R 60 - AC coil operating range v ambient temperatureR 60 - DC coil operating range v ambient temperature
L1 L 2 S1
K1
C
L
N
Coil code I
min
(A) IN(A) I
max
(A) R (Ω) 4251 2.1 2.5 3.0 0.05 4181 1.5 1.8 2.2 0.10 4161 1.4 1.6 1.9 0.12 4121 1.0 1.2 1.4 0.22 4101 0.85 1.0 1.2 0.32 4051 0.42 0.5 0.6 1.28 4041 0.34 0.4 0.5 2.00 4031 0.25 0.3 0.4 3.57 4021 0.17 0.2 0.25 8.0 4011 0.085 0.1 0.15 32.1
Current sensing AC coil data
Coil code I
min
(A) IN(A) I
max
(A) R (Ω) 4202 1.7 2.0 2.4 0.15 4182 1.5 1.8 2.2 0.19 4162 1.4 1.6 1.9 0.24 4142 1.2 1.4 1.7 0.31 4122 1.0 1.2 1.4 0.42 4102 0.85 1.0 1.2 0.61 4092 0.8 0.9 1.1 0.75 4062 0.5 0.6 0.7 1.70 4032 0.25 0.3 0.4 6.70 4012 0.085 0.1 0.15 61
Current sensing DC coil data
Other types of current sensing relays are available on request.
60 Series - General purpose relays 6 - 10 A
(°C)
6030 50
2.0
10-20
1.0
0.5
1.5
0407020-10
U U
N
80
2
1
Sheet of marker tags for relay types 60.12 and 60.13, plastic, 72 tags, 6x12 mm 060.72
060.72
Accessories
60
Page 7
60 Series General Purpose Relays 10 A
62
2 7
10
2
7
10
27
10
27
10
Coil version = 3 Option = 0030 Option = 0060 - 0070 Option = 0080 - 0090
ORDERING INFORMATION
OPTIONS
Example: a 60 series P.C.B.relay, 3 CO (3PDT) with coil rated 12 V DC.
Coil version
3 = DC diode in parallel to
coil (positive to pin 2) 8 = AC (50/60 Hz) 9 = DC
Type
4 = P.C.B.
No. of poles
2 = 2 CO (DPDT) 3 = 3 CO (3PDT)
Coil voltage
006 = 6 V 012 = 12 V 024 = 24 V 048 = 48 V 060 = 60 V 110 = 110 V 120 = 120 V AC only 230 = 230 V AC only 240 = 240 V AC only
Contact material and contact circuit
00 = Standard 20 = AgCdO 50 = AgNi + 5µm Au
Series
6 0
0 1 24 3
0
0
0
0
9
Options
00 = Standard