Nominal Coil Operating range Resistance Rated coil
voltage code
consumption
U
N
U
min
U
max
R
I at UN(50Hz)
VVVΩ mA
6 8.006 4.8 6.6 5.7 300
12 8.012 9.6 13.2 22 150
24 8.024 19.2 26.4 81 90
48 8.048 38.4 52.8 380 37
60 8.060 48 66 600 30
110 8.110 88 121 1,900 16.5
120 8.120 96 132 2,560 13.4
230 8.230 184 253 7,700 9
240 8.240 192 264 10,000 7.5
400 8.400 320 440 26,000 4.9
Nominal Coil Operating range Resistance Rated coil
voltage code
consumption
U
N
U
min
U
max
R I at U
N
VVVΩ mA
6 9.006 4.8 6.6 40 150
12 9.012 9.6 13.2 140 86
24 9.024 19.2 26.4 600 40
48 9.048 38.4 52.8 2,400 20
60 9.060 48 66 4,000 15
110 9.110 88 121 12,500 8.8
125 9.125 100 137.5 17,300 7.2
220 9.220 176 242 54,000 4
Nominal Coil Operating range Resistance Rated coil
voltage code
consumption
U
N
U
min
*U
max
R
I at UN(50Hz)
VVVΩ mA
6 8.006 4.8 6.6 12 200
12 8.012 9.6 13.2 50 97
24 8.024 19.2 26.4 190 53
48 8.048 38.4 52.8 770 25
60 8.060 48 66 1,200 21
110 8.110 88 121 3,940 12.5
120 8.120 96 132 4,700 12
230 8.230 184 253 17,000 6
240 8.240 192 264 19,100 5.3
AC coil data, 2 pole relayDC coil data, 2 pole relay
Nominal Coil Operating range Resistance Rated coil
voltage code
consumption
U
N
U
min
U
max
R I at U
N
VVVΩ mA
6 9.006 5.1 6.6 32.5 185
12 9.012 10.2 13.2 123 97
24 9.024 20.4 26.4 490 49
48 9.048 40.8 52.8 1,800 27
60 9.060 51 66 3,000 20
110 9.110 93.5 121 10,400 10.5
125 9.125 107 137.5 14,200 8.8
220 9.220 187 242 44,000 5
AC coil data, 4 pole relayDC coil data, 4 pole relay
Coil specifications
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
R 56 - AC coil operating range v ambient temperature
2 pole relay
R 56 - DC coil operating range v ambient temperature
2 pole relay
R 56 - DC coil operating range v ambient temperature
4 pole relay
R 56 - AC coil operating range v ambient temperature
4 pole relay
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
*
U
min
= 0.85 UNfor normally open version.
normally open version
changeover version