FINDER 41.52.8.024.0010, 41.52.9.048.0010, 41.31.9.012.0010, 41.61.9.012.0010, 41.61.9.024.0010 Specification

...
Page 1
1 CO (SPDT) 2 CO (DPDT) 1 CO (SPDT)
12/25 8/15 16/30
250/400 250/400 250/400
3,000 2,000 4,000
600 400 750
0.5 0.3 0.5
12/0.3/0.12 8/0.3/0.12 16/0.3/0.12
AgNi AgNi AgNi
———
12 - 24 - 48 - 60 - 110 12 - 24 - 48 - 60 - 110 12 - 24 - 48 - 60 - 110
—/0.4 —/0.4 —/0.4
———
(0.7...1.5)U
N
(0.7...1.5)U
N
(0.7...1.5)U
N
—/0.4U
N
—/0.4 U
N
—/0.4 U
N
—/0.1U
N
—/0.1 U
N
—/0.1 U
N
—/30·10
6
—/30·10
6
—/30·10
6
150 · 10
3
80 · 10
3
70 · 10
3
5/4 5/4 5/4
6 (8 mm) 6 (8 mm) 6 (8 mm)
1,000 1,000 1,000
–40…+85 –40…+85 –40…+85
RT II RT II RT II
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Single phase motor rating (230 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (U
N
) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Holding voltage AC/DC
Must drop-out voltage AC/DC
Technical data
Mechanical life AC/DC cycles
Electrical life at rated load AC1 cycles
Operate/release time ms
Insulation between coil and contacts (1.2/50 µs)
kV
Dielectric strength between open contacts V AC
Ambient temperature range °C
Environmental protection
Approvals (according to type)
Copper side view Copper side view Copper side view
1
Features
1 & 2 Pole - Low profile (15.7 mm height)
41.31 - 1 Pole 12 A (3.5 mm pin pitch)
41.52 - 2 Pole 8 A (5 mm pin pitch)
41.61 - 1 Pole 16 A (5 mm pin pitch) PCB mount
- direct or via PCB socket
35 mm rail mount
- via screw and screwless sockets
DC coils - 400 mW
8 mm, 6 kV (1.2/50 µs) isolation, coil-contacts
Cadmium Free contact materials
Flux proof: RT II standard, (RT III option)
3.5 mm contact pin pitch
1 Pole 12 A
PCB direct or via socket
5 mm contact pin pitch
2 Pole 8 A
PCB direct or via socket
5 mm contact pin pitch
1 Pole 16 A
PCB direct or via socket
F
OR UL HORSEPOWER AND PILOT DUTY RATINGS
SEE “General technical information” page V
41 Series - Low profile PCB relays 8 - 12 - 16 A
41.31 41.52 41.61
Page 2
41.81 - 9024 41.81 - 8240
1 NO (SPST-NO) 1 NO (SPST-NO)
5/40 3/40
(24/35)DC (240/275)AC
(1.5...35)DC (12...275)AC
150
0.01 1
0.3 1.1
12 24 12 24
8...17 14...32 8...17 14...32
5.5 9 8.8 9
4949
1,550 2,600 1,030 2,600
0.05/0.25 10/10
2,500 2,500
–20...+60 –20...+60
RT III RT III
Output circuit
Contact configuration
Rated current/Maximum peak current (100 µs)A
Rated voltage/Maximum blocking voltage V
Switching voltage range V
Minimum switching current mA
Max. “OFF-state” leakage current mA
Max. “ON-state” voltage drop V
Input circuit
Nominal voltage V DC
Operating range V DC
Control current mA
Release voltage V DC
Impedance Ω
Technical data
Operate/release time ms
Dielectric strength between input/output V
Ambient temperature range °C
Environmental protection
Approvals (according to type)
Copper side view Copper side view
Features
Solid State Relays Printed circuit mount:
- direct or via PCB socket
35 mm rail mount:
- via screw or screwless sockets
Single circuit output switching options
- 5 A 24 V DC
- 3 A 240 V AC
Silent, high speed switching with long
electrical life
Low profile (15.7 mm)
Wash tight: RT III
2,500 V insulation, input-output
5 A, 24 V DC output switching
PCB or 93 Series sockets
3 A, 240 V AC output switching
Zero crossing switching
PCB or 93 Series sockets
41 Series - Low profile PCB relays (SSR) 3 - 5 A
2
Page 3
Example: 41 series low-profile PCB relay, 2 CO (DPDT), 24 V DC coil.
A: Contact material
0 = Standard AgNi 4 = AgSnO
2
5 = AgNi + Au (5 µm)
B: Contact circuit
0 = CO (nPDT) 3 = NO (nPST)
Series Typ e
3 = PCB - 3.5 mm pinning 5 = PCB - 5 mm pinning 6 = PCB - 5 mm pinning
No. of poles
1 = 1 pole for
41.31, 12 A
41.61, 16 A
2 = 2 pole for
41.52, 8 A
Coil version
9 = DC
Coil voltage
See coil specifications
D: Special versions
0 = Flux proof (RT II) 1 = Wash tight (RT III)
C: Options
1 = None
ABCD
41 Series - Low profile PCB relays
Ordering information
5 2 09
... .
02441
0 1 0
Type Coil version A B C D
41.31 DC 0 - 4 - 5 0 - 3 10- 1
41.52 DC 0 - 5 0 - 3 10- 1
41.61 DC 0 - 4 0 - 3 10- 1
Selecting features and options: only combinations in the same row are possible.
Preferred selections for best availability are shown in bold.
Example: 41 series SSR relay, 5 A output, 24 V DC supply.
Output circuit
9024 = 5 A - 24 V DC 8240 = 3 A - 240 V AC
Series Typ e
8 = SSR type
Output
1 = 1 NO (SPST-NO)
Input circuit
See input specifications
8 1 7
... .
024
9024
41
Solid state relay (SSR)
3
Electromechanical relay (EMR)
Page 4
4
41 Series - Low profile PCB relays
Technical data
Insulation according to EN 61810-1
1 pole 2 pole
Nominal voltage of supply system V AC 230/400 230/400 Rated insulation voltage V AC 250 400 250 400 Pollution degree 3 2 3 2
Insulation between coil and contact set
Type of insulation Reinforced (8 mm) Reinforced (8 mm) Overvoltage category III III Rated impulse voltage kV (1.2/50 µs) 6 6 Dielectric strength V AC 4,000 4,000
Insulation between adjacent contacts
Type of insulation Basic Overvoltage category III Rated impulse voltage kV (1.2/50 µs) — 4 Dielectric strength V AC — 2,000
Insulation between open contacts
Type of disconnection Micro-disconnection Micro-disconnection Dielectric strength V AC/kV (1.2/50 µs) 1,000/1.5 1,000/1.5
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2 EN 61000-4-4 level 4 (4 kV) Surge (1.2/50 µs) on A1 - A2 (differential mode) EN 61000-4-5 level 3 (2 kV)
Other data
Bounce time: NO/NC ms 2/5 Vibration resistance (5…55)Hz: NO/NC g 15/2 Shock resistance g 16 Power lost to the environment without contact current W 0.4
with rated current W 1.7 (41.31) 1.2 (41.52) 1.8 (41.61)
Recommended distance between relays mounted on PCB mm ≥ 5
Electromechanical relay
Page 5
5
Coil specifications
Nominal Coil Operating range Resistance Rated coil
voltage code
consumption
U
N
U
min
U
max
R I at U
N
VVVΩ mA 12 9.012 8.4 18 360 33.3 24 9.024 16.8 36 1,440 16.7 48 9.048 33.6 72 5,760 8.3 60 9.060 42 90 9,000 6.6
110 9.110 77 165 24,200 4.5
1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature.
F 41 - Electrical life (AC) v contact current
Types 41.31/61
Cycles
H 41- Maximum DC1 breaking capacity
41 Series - Low profile PCB relays
Contact specification
DC coil data
When switching a resistive load (DC1) having voltage and current
values under the curve, an electrical life of ≥ 100·103can be expected.
In the case of DC13 loads, the connection of a diode in parallel with
the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased.
DC breaking current (A)
DC voltage (V)
R 41- DC coil operating range v ambient temperature
F 41 - Electrical life (AC) v contact current
Type 41.52
Cycles
Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4
limit for 41.31
Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4
41.52 - 2 contacts in series
single contact
41.61 limit current
41.31 limit current
41.52 limit current
Page 6
41 Series - Low profile PCB relays
Solid state relay
Technical data
Other data 41.81 - 9024 41.81 - 8240
Power lost to the environment without current W 0.25 0.25
with maximum current W 1.75 3.5
Nominal Input Operating range Release Impedance Control
voltage code voltage current
U
N
U
min
U
max
I at U
N
VVVVΩ mA
12 7.012 8 17 4 1,550 5.5 24 7.024 14 32 9 2,600 9
Input data - DC types
Input specification
Output specification
Output current
Output current
L 41 - Output current v ambient temperature
SSR - 5 A DC output types
L 41 - Output current v ambient temperature
SSR - 3 A AC output types
6
Page 7
93.02
93 Series - Sockets and accessories for 41 series relays
Screw terminal socket 35 mm (EN 60715) mounting Supply voltage Relay type Socket type
6 V AC/DC 41.52.9.005.0010 93.02.0.024 12 V AC/DC 41.52.9.012.0010 93.02.0.024 24 V AC/DC 41.52.9.024.0010 or 41.81.7.024.xxxx 93.02.0.024 60 V AC/DC 41.52.9.060.0010 93.02.0.060 (110...125)V AC/DC 41.52.9.110.0010 93.02.0.125 (220...240)V AC/DC 41.52.9.110.0010 93.02.0.240 (230...240)V AC 41.52.9.110.0010 93.02.8.230 6 V DC 41.52.9.005.0010 93.02.7.024 12 V DC 41.52.9.012.0010 or 41.81.7.012.xxxx 93.02.7.024 24 V DC 41.52.9.024.0010 or 41.81.7.024.xxxx 93.02.7.024 48 V DC 41.52.9.048.0010 93.02.7.060 60 V DC 41.52.9.060.0010 93.02.7.060
Accessories
8-way jumper link
093.08
(see specification next page)
Plastic separator
093.01
(see specification next page)
Sheet of marker tags
, 72 tags 090.72
(see specification next page)
Technical data
Rated values
10 A - 250 V
Dielectric strength
6 kV (1.2/50 µs)
between coil and contacts
Protection category
IP 20
Ambient temperature
°C
(–40…+70)°C - (UN≤ 60 V DC), (–40…+55)°C - (UN> 60 V DC)
Screw torque
Nm 0.5
Wire strip length
mm 8
Max. wire size for 93.02 socket solid wire stranded wire
mm21x6 / 2x2.5 1x4 / 2x2.5
AWG 1x10 / 2x14 1x12 / 2x14
Approvals (according to type):
7
Page 8
93.52
Screwless terminal socket 35 mm (EN 60715) mounting Supply voltage Relay type Socket type
6 V AC/DC 41.52.9.005.0010 93.52.0.024 12 V AC/DC 41.52.9.012.0010 93.52.0.024 24 V AC/DC 41.52.9.024.0010 or 41.81.7.024.xxxx 93.52.0.024 60 V AC/DC 41.52.9.060.0010 93.52.0.060 (110...125)V AC/DC 41.52.9.110.0010 93.52.0.125 (220...240)V AC/DC 41.52.9.110.0010 93.52.0.240 (230...240)V AC 41.52.9.110.0010 93.52.8.230 6 V DC 41.52.9.005.0010 93.52.7.024 12 V DC 41.52.9.012.0010 or 41.81.7.012.xxxx 93.52.7.024 24 V DC 41.52.9.024.0010 or 41.81.7.024.xxxx 93.52.7.024 48 V DC 41.52.9.048.0010 93.52.7.060 60 V DC 41.52.9.060.0010 93.52.7.060
Accessories
8-way jumper link
093.08
(see table below)
Plastic separator
093.01
(see table below)
Sheet of marker tags
, 72 tags 090.72
(see table below)
Technical data
Rated values
10 A - 250 V
Dielectric strength
6 kV (1.2/50 µs)
between coil and contacts
Protection category
IP 20
Ambient temperature
°C
(–40…+70)°C - (UN≤ 60 V DC), (–40…+55)°C - (UN> 60 V DC)
Wire strip length
mm 8
Max. wire size for 93.52 socket solid wire stranded wire
mm21x2.5 1x2.5
AWG 1x14 1x14
Approvals (according to type):
93 Series - Sockets and accessories for 41 series relays
Accessories
Approvals (according to type):
8-way jumper link for 93.02 and 93.52 sockets 093.08 (blue) 093.08.0 (black) Rated values 10 A - 250 V
Plastic separator for 93.02 and 93.52 sockets 093.01 Thickness 2 mm, required at the start and the end of a group of interfaces.
Can be used for visual separation group, must be used for:
- protective separation of different voltages of neighbouring PLC interfaces according to VDE 0106-101
- protection of cut jumper links
Sheet of marker tags for 38.x2, plastic, 72 tags, 6x12 mm 060.72
8
093.08
093.01
060.72
Page 9
20
30
3. 5
13
7.5
3. 51. 5
41.52 41.81 - 9024
41.81 - 8240
41.31
95.13.2 95.15.2
41.61
9
1 3
.
95 SL A
1 3
.
2
.
2
.
95
95 Series - Sockets and accessories for 41 series relays
How to code and identify retaining clip and packaging options for sockets.
Example:
Packaging codes
A Standard packaging
Without retaining clip
SL Plastic retaining clip
Approvals (according to type):
PCB socket
95.13.2 (blue)
95.13.20 (black)
95.15.2 (blue)
95.15.20 (black)
For relay type 41.31 41.52, 41.61, 41.81
(1)
Accessories
Plastic retaining clip 095.42
Technical data
Rated values 10 A - 250 V * Dielectric strength 6 kV (1.2/50 µs) between coil and contacts Protection category IP 20 Ambient temperature °C –40…+70
* For currents >10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12).
(1)
With the relay 41.81 the NO change-over contact will be 11-14.
Copper side view
Copper side view
95.15.2
95.13.2
Page 10
Loading...