finder 30.22 User Manual

Low coil power
Au clad contacts
PCB mount
2 CO (DPDT)
2/3
125/250
125
25
2/0.3/—
10 (0.1/1)
AgNi + Au
5 - 6 - 9 - 12 - 24 - 48
—/0.2
See table page 2
—/0.35 U
N
—/0.05 U
N
—/10 · 10
6
100 · 10
3
6/2
1.5
750
–40…+85
RT III
30.22
1
30 Series - Subminiature DIL relays 2 A
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Single phase motor rating (230 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (U
N
) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Holding voltage AC/DC
Must drop-out voltage AC/DC
Technical data
Mechanical life AC/DC cycles
Electrical life at rated load AC1 cycles
Operate/release time ms
Insulation between coil and contacts (1.2/50 µs)
kV
Dielectric strength between open contacts V AC
Ambient temperature range °C
Environmental protection
Approvals (according to type)
Copper side view
Features
Printed circuit mount 2 A signal relay
2 Pole changeover contacts
Low level switching capability
Subminiature - industry standard DIL package
Sensitive DC coil - 200 mW
Wash tight: RT III
Cadmium Free contact material
20.3
0.7
7.62
5.08
5.08
1.1
10.1
11.4
4
0.4
7.62
14
12
11
A1
21
A2
22
24
7.62
12
11 21
A1
0.8
14 22 24
A2
Technical data
Insulation
Insulation according to EN 61810-1 insulation rated voltage V 125 250
rated impulse withstand voltage kV 1.2 1.2 pollution degree 2 1
overvoltage category I I Insulation between coil and contacts (1.2/50 µs) kV 1.5 Dielectric strength between open contacts V AC 750 Dielectric strength between adjacent contacts V AC 1,500
Other data
Bounce time: NO/NC ms 1/3 Vibration resistance (5…55)Hz, max. ± 1 mm: NO/NC g 15/15 Shock resistance g16 Power lost to the environment without contact current W 0.2
with rated current W 0.4 Recommended distance between relays mounted on PCB mm ≥ 5
Nominal Coil Operating range Resistance Rated coil
voltage code
consumption
U
N
U
min
U
max
R I at U
N
VVV mA
5 7.005 3.7 7.5 125 40 6 7.006 4.5 9 180 33
9 7.009 6.7 13.5 405 22 12 7.012 8.4 18 720 16 24 7.024 16.8 36 2,880 8.3 48 7.048 36 72 11,520 4.1
DC coil data - 0.2 W sensitive
Coil specifications
1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature.
Example: 30 series PCB relay, 2 CO (DPDT) - 2 A contacts, 12 V sensitive DC coil.
A: Contact material
0 = Standard
AgNi + Au (5 µm)
B: Contact circuit
0 = CO (DPDT)
Coil voltage
See coil specifications
Series
Type
2 = PCB mount
No. of poles
2 = 2 pole, 2 A
Coil version
7 = Sensitive DC
2 2 07
D: Special versions
0 = Wash tight (RT III)
C: Options
1 = None
Ordering information
ABCD
... .
01230
30 Series - Subminiature DIL relays 2 A
2
0 1 0
F 30 - Electrical life (AC1) v contact current (125 V)
Cycles
Contact specification
R 30 - DC coil operating range v ambient temperature
Note: The rated current of 2 A corresponds to the limiting continuous current.
7
10
6
10
5
10
0
1
1,50,5
2
(A)
U
2.5
U
N
2.0
1.5
1.0
0.5
-20
04020
1
2
60
80
(°C)
Loading...