3
Ordering information
Coil specifications
Nominal Coil Operating range Resistance
Consumption
voltage code
I at U
N
U
N
U
min
U
max
R
(50 Hz)
VVVΩ mA
8 8.008 6.8 8.8 6.5 360
12 8.012 10.2 13.2 13.5 245
24 8.024 20.4 26.4 41 135
48 8.048 40.8 52.8 186 68
110 8.110 93.5 121 970 26
120 8.120 102 132 1,380 24
230 8.230 196 253 4,200 12.5
240 8.240 204 264 4,400 12
AC version data
Nominal Coil Operating range Resistance
Consumption
voltage code
I at U
N
U
N
U
min
U
max
R
VVVΩ mA
12 9.012 10.8 13.2 115 104
24 9.024 21.6 26.4 460 52.2
48 9.048 43.2 52.8 1,850 25.9
110 9.110 99 121 9,700 11.3
DC version data
If the coil is operated for a prolonged period of time, adequate ventilation of the relays must be provided - suggested gap of 9 mm between
adjacent relays.
Example: 22 series 35 mm rail mount relay, 1 NO (SPST-NO) 20 A contact, coil rated 24 V DC, contact material AgSnO2.
Contact material
4 = AgSnO
2
Coil voltage
See coil specifications
Coil version
8 = AC (50/60 Hz)
9 = DC
Series
Typ e
2 = 35 mm rail (EN 60715) mount
No. of poles
1 = 1 NO (SPST-NO)
2 = 2 NO (DPST-NO)
3 = 1 NO + 1 NC (SPST-NO + SPST-NC)
4 = 2 NC (DPST-NC)
2 1 09 0 0
... .
02422 4
22 Series - Modular monostable relays 20 A
Technical data
Contact specifications
Nominal rate lamps
incandescent (230V) W 1,000
compensated fluorescent (230V) W 360
Insulation
Dielectric strength
between supply and contacts V AC 3,500
between open contacts V AC 2,000
between adjacent contacts V AC 2,000
Other data
Bounce time: NO / NC ms 5 / 10
Power lost to the environment
without contact current W 1.2
with rated current W 3.2 (22.21, 22.23) 5.2 (22.22, 22.24)
Screw torque Nm 0.8 0.8
Coil terminals Contact terminals
Max. wire size solid cable stranded cable solid cable stranded cable
mm21x4 / 2x2.5 1x2.5 / 2x2.5 1x6 / 2x6 1x6 / 2x4
AWG 1x12 / 2x14 1x14 / 2x14 1x10 / 2x10 1x10 / 2x12