FINDER 062.10 Specification

Page 1
62.22 / 62.23 62.22-0300 / 62.23-0300
2 CO (DPDT) 3 CO (3PDT)
2 NO (DPST-NO), ≥ 3 mm*
3 NO (3PST-NO), ≥ 3 mm*
250/400 250/400
4,000 4,000
750 750
0.8/— 0.8/1.5 0.8/— 0.8/1.5
16/0.6/0.4 16/1.1/0.7
1,000 (10/10) 1,000 (10/10)
AgCdO AgCdO
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2.2/1.3 3/3
(0.8…1.1)U
N
(0.85…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 UN/0.6 U
N
0.8 UN/0.6 U
N
0.2 UN/0.1 U
N
0.2 UN/0.1 U
N
10 · 106/30 · 10
6
10 · 106/30 · 10
6
100 · 10
3
100 · 10
3
10/10 20/4
66
1,500 2,500
–40…+70 –40…+50
RT I RT I
2 & 3 pole changeover contact
PCB mount
2 & 3 pole normally open contact
(3 mm contact gap)
PCB mount
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Motor rating (230/400 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (U
N
) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Holding voltage AC/DC
Must drop-out voltage AC/DC
Technical data
Mechanical life AC/DC cycles
Electrical life at rated load AC1 cycles
Operate/release time ms
Insulation between coil and contacts (1.2/50 µs)
kV
Dielectric strength between open contacts V AC
Ambient temperature range °C
Environmental protection
Approvals (according to type)
62.22 62.23 62.22 - 0300 62.23 - 0300
Copper side view Copper side view Copper side view Copper side view
* Distance between contacts 3 mm
(EN 60730-1).
** With the AgSnO
2
material the
maximum
peak
current is 120 A - 5 ms (NO contact).
F
OR UL HORSEPOWER AND PILOT DUTY RATINGS
SEE “General technical information” page V
1
Features
Printed circuit mount 16 A Power relay
2 & 3 Pole changeover contacts or NO
(3 mm contact gap)
AC coils & DC coils
Reinforced insulation between coil and
contacts according to EN 60335-1, with 6 mm clearance & 8 mm creepage distance
SELV coil-contact separator option
Cadmium Free contact material options
62.23
62.23-0300
62.2x-030062.2x62.22
62.22-0300
62 Series - Power relays 16 A
Page 2
62.32 / 62.33 62.32-0300 / 62.33-0300
2 CO (DPDT) 3 CO (3PDT)
2 NO (DPST-NO), ≥ 3 mm*
3 NO (3PST-NO), ≥3 mm*
250/400 250/400
4,000 4,000
750 750
0.8/— 0.8/1.5 0.8/— 0.8/1.5
16/0.6/0.4 16/1.1/0.7
1,000 (10/10) 1,000 (10/10)
AgCdO AgCdO
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2.2/1.3 3/3
(0.8…1.1)U
N
(0.85…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 UN/0.6 U
N
0.8 UN/0.6 U
N
0.2 UN/0.1 U
N
0.2 UN/0.1 U
N
10 · 106/30 · 10
6
10 · 106/30 · 10
6
100 · 10
3
100 · 10
3
10/10 20/4
66
1,500 2,500
–40…+70 –40…+50
RT I RT I
2 & 3 pole changeover contact
Plug-in / Faston 187
2 & 3 pole normally open contact
(3 mm contact gap)
Plug-in / Faston 187
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Motor rating (230/400 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (U
N
) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Holding voltage AC/DC
Must drop-out voltage AC/DC
Technical data
Mechanical life AC/DC cycles
Electrical life at rated load AC1 cycles
Operate/release time ms
Insulation between coil and contacts (1.2/50 µs)
kV
Dielectric strength between open contacts V AC
Ambient temperature range °C
Environmental protection
Approvals (according to type)
*
Distance between contacts 3 mm (EN 60730-1).
** With the AgSnO2 material the
maximum
peak
current is 120 A - 5 ms (NO contact).
F
OR UL HORSEPOWER AND PILOT DUTY RATINGS
SEE “General technical information” page V
Features
Plug-in mount/Faston 187 16 A Power relay
Plug-in (92 series sockets) or Faston 187
(4.8x0.5 mm) with optional mounting adaptors
2 & 3 Pole changeover contacts or NO
(3 mm contact gap)
AC coils & DC coils
UL Listing (certain relay/socket combinations)
LED, mechanical indicator & test button options
Reinforced insulation between coil and
contacts according to EN 60335-1, with 6 mm clearance & 8 mm creepage distance
SELV coil-contact separator option
Cadmium Free contact material options
Sockets and accessories
2
62.33
62.33-0300
62.3x-030062.3x62.32
62.32-0300
62.32 62.33
62.32-0300 62.33-0300
62 Series - Power relays 16 A
Page 3
62.82 / 62.83 62.82-0300 / 62.83-0300
2 CO (DPDT) 3 CO (3PDT)
2 NO (DPST-NO), ≥ 3 mm* 3 NO (3PST-NO), ≥ 3 mm*
250/400 250/400
4,000 4,000
750 750
0.8/— 0.8/1.5 0.8/— 0.8/1.5
16/0.6/0.4 16/1.1/0.7
1,000 (10/10) 1,000 (10/10)
AgCdO AgCdO
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2.2/1.3 3/3
(0.8…1.1)U
N
(0.85…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 UN/0.6 U
N
0.8 UN/0.6 U
N
0.2 UN/0.1 U
N
0.2 UN/0.1 U
N
10 · 106/30 · 10
6
10 · 106/30 · 10
6
100 · 10
3
100 · 10
3
10/10 20/4
66
1,500 2,500
–40…+70 –40…+50
RT I RT I
2 & 3 pole changeover contact
Flange mount / Faston 250
2 & 3 pole normally open contact
(3 mm contact gap)
Flange mount / Faston 250
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Motor rating (230/400 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (U
N
) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Holding voltage AC/DC
Must drop-out voltage AC/DC
Technical data
Mechanical life AC/DC cycles
Electrical life at rated load AC1 cycles
Operate/release time ms
Insulation between coil and contacts (1.2/50 µs)
kV
Dielectric strength between open contacts V AC
Ambient temperature range °C
Environmental protection
Approvals (according to type)
* Distance between contacts 3 mm
(EN 60730-1).
** With the AgSnO
2
material the
maximum
peak
current is 120 A - 5 ms (NO contact).
F
OR UL HORSEPOWER AND PILOT DUTY RATINGS
SEE “General technical information” page V
Features
Flange mount/Faston 250 16 A Power relay
Faston 250 (6.3x0.8 mm) termination Flange
or optional mounting adaptors
2 & 3 Pole changeover contacts or NO
(3 mm contact gap)
AC coils & DC coils
LED, mechanical indicator & test button options
Reinforced insulation between coil and
contacts according to EN 60335-1, with 6 mm clearance & 8 mm creepage distance
SELV coil-contact separator option
Cadmium Free contact material options
3
62.83
62.83-0300
62.8x-030062.8x62.82
62.82-0300
62.82 62.83
62.82-0300 62.83-0300
62 Series - Power relays 16 A
Page 4
Example: 62 series power relay + Faston 250 (6.3x0.8 mm), rear flange mount, 2 NO (DPST-NO), 12 V DC coil.
Type Coil version A B C D
62.22/23 AC-DC 0 - 4 0 - 3 - 5 - 6 00
62.32/33 AC-DC 0 - 4 0 - 3 - 5 - 6 0 0 - 6 AC-DC 0 - 4 0 - 5 2 - 40- 6 AC 0 - 4 0 2 - 3 - 4 - 5 0 - 6 AC 0 - 4 0 - 3 3 0 - 6 AC 0 - 4 0 54 / DC 0 - 4 04- 6 - 7 0 - 6 DC 0 - 4 0 - 3 6 0 - 6 DC 0 - 4 0 74 /
62.82/83 AC-DC 0 - 4 0 - 3 - 5 - 6 00- 9 AC-DC 0 - 4 0 - 5 2 - 4 0 AC 0 - 4 0 2 - 3 - 4 - 5 0 AC 0 - 4 0 - 3 3 0 DC 0 - 4 0 4 - 6 - 7 0 DC 0 - 4 0 - 3 6 0
4
62 Series - Power relays 16 A
A: Contact material
0 = Standard AgCdO 4 = AgSnO
2
B: Contact circuit
0 = CO (nPDT) 3 = NO (nPST),
3 mm contact gap
5 = CO (nPDT) + additional
physical separator between coil and contacts (for SELV applications)
6 = NO (nPST), 3 mm contact
gap + additional physical separator between coil and contacts (for SELV applications)
Series Typ e
2 = PCB 3 = Plug-in 8 = Faston 250 (6.3x0.8 mm)
with rear flange mount
No. of poles
2 = 2 pole 3 = 3 pole
Coil version
8 = AC (50/60 Hz) 9 = DC
Coil voltage
See coil specifications
8 2 0 39
D: Special versions
0 = Standard 6 = Rear flange mount 9 = Type 62.82/83 without rear flange
mount
C: Options
0 = None 2 = Mechanical indicator 3 = LED (AC) 4 = Lockable test button +
mechanical indicator 5* = Lockable test button + LED (AC) 54* = Lockable test button + LED (AC) +
mechanical indicator 6* = LED + diode
(DC, polarity positive to pin A/A1) 7* = Lockable test button + LED + diode
(DC, polarity positive to pin A/A1) 74* = Lockable test button + LED + diode
(DC, polarity positive to pin A/A1) +
mechanical indicator * Options not available for 220 V DC and
400 V AC versions.
0 0
Ordering information
ABCD
... .
01262
Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold.
Lockable test button and mechanical flag indicator
(0040, 0050, 0054, 0070, 0074)
The dual-purpose Finder test button can be used in two ways: Case 1
) The plastic pip (located directly above the test button) remains intact. In this case, when the test button is pushed, the contacts operate. When the test button is released the contacts return to their former state. Case 2)
The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to the above function), when the test button is pushed and rotated, the contacts are latched in the operating state, and remain so until the test button is rotated back to its former position. In both cases ensure that the test button actuation is swift and decisive.
B: Contact circuit 5, 6
Additional physical separator between coil and contacts (for SELV applications)
C: Option 3, 5, 54
LED (AC)
C: Option 6, 7, 74
LED + diode (DC, polarity
positive to pin A/A1)
Descriptions: Options and Special versions
1
2
3
Page 5
5
62 Series - Power relays 16 A
Technical data
Insulation according to EN 61810-1
2 CO - 3 CO 2 NO - 3 NO
Nominal voltage of supply system V AC 230/400 230/400 Rated insulation voltage V AC 400 400 Pollution degree 3 3
Insulation between coil and contact set
Type of insulation Reinforced Reinforced Overvoltage category III III Rated impulse voltage kV (1.2/50 µs) 6 6 Dielectric strength V AC 4,000 4,000
Insulation between adjacent contacts
Type of insulation Basic Basic Overvoltage category III III Rated impulse voltage kV (1.2/50 µs) 4 4 Dielectric strength V AC 2,500 2,500
Insulation between open contacts
Type of disconnection Micro-disconnection Full-disconnection Overvoltage category III Rated impulse voltage kV (1.2/50 µs) — 4 Dielectric strength V AC/kV (1.2/50 µs) 1,500/2 2,500/4
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2 EN 61000-4-4 level 4 (4 kV) Surge (1.2/50 µs) on A1 - A2 (differential mode) EN 61000-4-5 level 4 (4 kV)
Other data
Bounce time: NO/NC ms 3/6 (changeover) 3/— (normally open) Vibration resistance (10…150)Hz: NO/NC g 20/8 Shock resistance g 15 Power lost to the environment 2 pole (CO) 3 pole (CO) 2 pole (NO) 3 pole (NO)
without contact current W 1.3 1.3 3 3 with rated current W 3.3 4.3 5 6
Recommended distance between relays mounted on PCB mm ≥ 5
Page 6
6
Contact specification
Voltage DC (V)
DC breeaking current (A)
F 62 - Electrical life (AC) v contact current
H 62 - Maximum DC1 breaking capacity
Normally open contacts
Voltage DC (V)
DC breaking current (A)
H 62 - Maximum DC1 breaking capacity
Changeover contacts
Cycles
When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of 100·103can be expected.
In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load.
Note: the release time of the load will be increased.
contacts in series
contacts in series
Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4
62 Series - Power relays 16 A
Page 7
7
62 Series - Power relays 16 A
Nominal Coil Operating range Resistance Rated coil
voltage code
consumption
U
N
U
min
U
max
R
I at UN (50Hz)
VVVΩ mA
6 8.006 5.1 6.6 4 540 12 8.012 10.2 13.2 14 275 24 8.024 20.4 26.4 62 130 48 8.048 40.8 52.8 220 70 60 8.060 51 66 348 55
110 8.110 93.5 121 1,200 30 120 8.120 106 137 1,350 24 230 8.230 196 253 5,000 14 240 8.240 204 264 6,300 12.5 400 8.400 340 440 14,700 7.8
Nominal Coil Operating range Resistance Rated coil
voltage code
consumption
U
N
U
min
U
max
R I at U
N
VVVΩ mA
6 9.006 5.1 6.6 12 500 12 9.012 10.2 13.2 48 250 24 9.024 20.4 26.4 192 125 48 9.048 40.8 52.8 770 63 60 9.060 51 66 1,200 50
110 9.110 93.5 121 4,200 26 125 9.125 106 138 5,200 24
220 9.220 187 242 17,600 12.5
Nominal Coil Operating range Resistance Rated coil
voltage code
consumption
U
N
U
min
U
max
R I at U
N
VVVΩ mA
6 9.006 4.8 6.6 28 214 12 9.012 9.6 13.2 110 109 24 9.024 19.2 26.4 445 54 48 9.048 38.4 52.8 1,770 27 60 9.060 48 66 2,760 21.7
110 9.110 88 121 9,420 11.7 125 9.125 100 138 12,000 10.4 220 9.220 176 242 37,300 5.8
Nominal Coil Operating range Resistance Rated coil
voltage code
consumption
U
N
U
min
U
max
R
I at UN(50Hz)
VVVΩ mA
6 8.006 4.8 6.6 4.6 367 12 8.012 9.6 13.2 19 183 24 8.024 19.2 26.4 74 90 48 8.048 38.4 52.8 290 47 60 8.060 48 66 450 37
110 8.110 88 121 1,600 20 120 8.120 96 132 1,940 18.6 230 8.230 184 253 7,250 10.5 240 8.240 192 264 8,500 9.2 400 8.400 320 440 19,800 6
AC version dataDC version data
Coil specifications
DC (NO/nPST-NO) version data - 3 mm
AC (NO/nPST-NO) version data - 3 mm
1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature.
1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature.
R 62 - DC coil operating range v ambient temperature
Changeover contacts
R 62 - AC coil operating range v ambient temperature
Changeover contacts
R 62 - DC coil operating range v ambient temperature
Normally open contacts
R 62 - AC coil operating range v ambient temperature
Normally open contacts
Page 8
8
62 Series - Power relays 16 A
Accessories
062.10
062.10 with relay
062.60
Mounting adaptor for types 62.3x and 62.8x.xxxx.xxx9 (M4) 062.10
Flange mounting adaptor for types 62.3x and 62.8x.xxxx.xxx9 062.60
062.60 with relay
062.10 with relay
062.60
062.10
062.60 with relay
062.05
Top flange mount for types 62.3x and 62.8x.xxxx.xxx9 062.05
062.05 with relay
062.05
062.05 with relay
062.07
Top 35 mm rail (EN 60715) mount for types 62.3x and 62.8x.xxxx.xxx9 062.07
062.07 with relay
062.07
062.07 with relay
Page 9
9
62 Series - Power relays 16 A
Accessories
Sheet of marker tags for 62 series relays, plastic, 72 tags, 6x12 mm 060.72
062.08
Rear 35 mm rail (EN 60715) mount for types 62.3x and 62.8x.xxxx.xxx9 062.08
062.08 with relay
062.08
062.08 with relay
060.72