Fincor Series 2120, Series 2130 Catalog Page

2120/2130
SINGLE-PHASE DC SERIES
HORSEPOWER RANGE (5) MODEL FUNCTION
115V 230V
NUMBER (3)
1/12-1/2 2121 Run-Stop 1/12-1/2 1/2-1
2122 Run-Stop
(2)
1/2-2
(2)
1/12-1 1/2-3 2123 Run-Stop
1/12 - 3 HP
115 or 230 V, Single Phase
Tach Feedback
Reversing Models
Current Limit
Compact “Micro Drives”
Budget Priced
Flexible — Modifiable with Standard
Options
NEMA 1 or NEMA 12 Enclosed
Models
Open Chassis Models
Local and Remote Control Models
UL Listed or UL Recognized
2120/2130-1
1/12 through 3 HP
Adjustable Speed
DC Motor Controllers
NOTES: (1) Model 2120 Units are furnished with a potentiometer rated 5K
ohms, 1/2 watt for separate mounting.
(2) Requires either option 1761 for 1 HP on 115 VAC and 2 HPon
230 VAC or option 1760 for 3/4 HPon 115 VAC and 1-1/2 HP on 230 VAC.
(3) Armature contactor Run-Stop-DB, and contactor reversing and
dynamic braking are provided by Options 1001E and 1004E.
(4) Panel assembly models do not include an enclosure. They are
intended for mounting on a door or other panel surface through an aperture cut into the User’s NEMA 1 or NEMA 12 enclosure.
(5) Units may be easily recalibrated for any standard rating within
the range of the product using trimpots.
TABLE 1: MODEL 2120 OPEN CHASSIS UNITS WITHOUT
OPERATOR CONTROLS (1) TABLE 2: ENCLOSED UNITS AND PANEL MOUNT (4)
HORSEPOWER RANGE (5) MODEL
TYPE FUNCTION
115V 230V
NUMBER
1/12-1/2 1/2-1 2131P1 NEMA 1 (4) Run-Stop
Panel Assembly
1/12-1/2 1/2-1 2131P1E NEMA 1 Run-Stop
Enclosed
1/12-1/2 1/2-1 2132P1E NEMA 12 Run-Stop
Enclosed
1/12-1/2 1/2-1 2131P2 NEMA 1 (4) Run-Stop-
Panel Assembly Reverse
1/12-1/2 1/2-1 2131P2E NEMA 1 Run-Stop-
Enclosed Reverse
1/12-1/2 1/2-1 2132P2E NEMA 12 Run-Stop-
Enclosed Reverse
FIGURE 1.
2120/2130
SINGLE-PHASE DC SERIES
2120/2130-2
DESIGN FEATURES AND FUNCTIONS
1. Enclosed Models — These units are furnished in a compact,
die cast aluminum, nonventilated enclosure. NEMA 1 and NEMA 12 models are offered. See Figure 3 for NEMA1 and Figure 4 for NEMA 12 model dimensions. The complete control assembly is mounted on the front panel which can be removed from the enclosure by removing screws. The unenclosed panel assembly can be mounted through a cut-out in the user’s enclosure, see Figure 5 for cut-out dimensions.
2. Chassis Models — The units are furnished as a very compact open chassis consisting of the regulator/power conversion circuit board mounted to a formed aluminum chassis. Some models may be furnished with supplemental heatsink (Options 1760, 1761) to improve heat dissipation and thereby extend the horsepower range. Chassis units are dimensionally interchangeable with many competitive units. See Figure 1 for dimensions of Models 2121 and 2122. See Figure 2 for dimensions of Model 2123.
3. Full-Wave Power Conversion — NEMA Code K converter configuration formed of discrete devices rated 600 PIV. Converter consists of two (2) SCR’s, two diodes and a free wheeling diode which provide optimum form factor for best motor performance and long service. Enclosed models use the control enclosure as an integral heatsink with the power control devices electrically isolated from the enclosure.
4. Voltage Transient Protection — Metal oxide suppressor across the AC line minimizes the effect of high voltage spikes from the AC power source.
5. Tachometer Feedback — All standard units except Model 2121 include a connection to accept a 35, 50 or 100 VDC/1000 RPM feedback signal from a motor mounted DC tachometer generator for improved speed regulation as shown in Table 4 (Unidirectional units only).
6. Horsepower Selection — Easily calibrated by built-in trimpots to suit individual motor horsepower ratings without special instruments, or plug-in shunts.
7. Wiring Terminals — Enclosed models are provided with barrier terminal strips for all external power and signal wires. Chassis models are provided with male tab wiring connectors. A terminal strip is offered as Options 1730Aand 1730B.
8. AC Line Fuse — Enclosed models include a fuse holder for an AC line fuse mounted on the circuit board. Chassis units do not include a fuse as standard, but a fuse holder may be provided with Options 1719, 1730A or 1730B.
9. Operator Controls — All enclosed models include integral operator controls consisting of a speed setting potentiometer and an ON-OFF AC line power switch. Switch is maintained in ON and OFF positions. Reversing models additionally include a 3­position FORWARD-STOP-REVERSE maintained switch. Switch includes a no pass through center detent which provides anti-plug protection.
Chassis units are controlled by external, customer furnished switches, pushbuttons, or control logic. Includes an inhibit circuit for automatic operation by switch, relay or PLC.
10. Line Voltage Selection — Line voltage selection is automatic without the use of jumpers or switches.
11. Field Supply — A full-wave, transient protected motor field supply is provided.
OPERATING CONDITIONS
1. Line Voltage Variation........................................... ±10% of rated
2. Line Frequency Variation.................................................. ±2 Hz
3. Ambient Temperature
Open Chassis Models.................................................. 0 to 50°C
(32°F to 104°F)
Enclosed Models.......................................................... 0 to 40°C
(32°F to 104°F)
4. Altitude (Standard)........................................................ 3300 feet
(1000 meters) maximum
RATINGS
1. Service Factor.......................................................................... 1.0
2. Duty.............................................................................. Continuous
3. Overload Capacity (armature circuit) (2) ........ 150% for 1 minute
4. Operating Voltages.................................................... See Table 3
5. Run Speed Potentiometer.................................... 5k ohms, 1/2W
6. Horsepower Range .............................................. See Tables 1, 2
7. Reference Power Supply (1)............................................. 10VDC
8. Line Fuse (2).................................................... Provided by others
NOTES:
(1) Units are optionally adapt-
able for use with 4-20 mA, and 0-10 VDC.
(2) A line fuse holder is pro-
vided as standard on 2131 and 2132 Models. Fuse clips are optional on all other models.
PERFORMANCE CHARACTERISTICS
1. Controlled speed range – Zero to motor base speed. Speed
range with respect to the specified regulation is as listed in Table
4. See Catalog Section E for continuous duty application limitations of DC Motors.
2. Speed Regulation – (See Table 4) - Regulation percentages
listed are of motor base speed under steady-state conditions. Normal operation will result in performance equal to or better than specified.
3. Efficiency (Rated Speed/Rated Load)
(a) Controller SCR regulator .................................................. 99%
(b) Complete drive with motor (typical) .................................. 85%
(1) Unidirectional models only.
ADJUSTMENTS
1. Current Limit .............................. 0-150% full-load torque (typical)
2. Maximum Speed ........................... 60-100% of motor base speed
3. Minimum Speed................................ 0-40% of motor base speed
4. IR (load) Compensation.............................. 0-100% of rated load
5. Acceleration/Deceleration (1)................................... 0-4 seconds
NOTES:
(1) Model 2121 Acceleration/Deceleration is 1.0 seconds fixed rate.
TABLE 3. OPERATING VOLTAGES
POWER SOURCE OUTPUT VDC
(Single-Phase) Armature Field
115V, 50 or 60Hz 0-90 100
230V, 50 or 60 Hz 0-180 200
TABLE 4. SPEED REGULATION CHARACTERISTICS
REGULATION
Load Line Field
Speed
METHOD
Change Voltage Heating Temperature
Range
95% ±10% Cold/Normal ±10°C
Standard
Voltage
Feedback 2% ±1% 5-12% ±2% 30:1
with IR
Compensation
Optional Speed
(Tach) 1% ±1% 0.2% ±2% 100:1
Feedback (1)