This manual is copyrighted with all rights reserved. Under the copyright law, this manual may not be copied, in whole or part,
without written consent of Philips. Under the law, copying includes translating into another language or format.
The device described in this manual, has been certified/registered by the safety agencies/regulatory authorities as
model n° : CMPD12CV-A and certified by FCC and IC governments agencies respectively as:
FCC ID: GZM802161 and 6319A-802161
FCC Notice
The device complies with part 15 of the FCC Rules. Operation is subjected to the following 2 conditions: (1) this device may
not cause harmful interference and (2) this device must accept any interference received, including interference that may
cause undesired operation.
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and , if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, while can be determined by turning the
equipment Off and On, the user is encouraged to try to correct the interference by one or more of the following measures.
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio TV technician for help.
Modification
The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly
approved by the manufacturer may void the user’s authority to operate the equipment.
Cables
Connections to this device must be made with shielded signals cables with metallic RFI/EMI connector hoods to maintain
compliance with FCC Rules and Regulations.
The lighting flash with arrowhead symbol is intend to alert the user of the presence of uninsulated “dangerous voltage”
within the product’s enclosure that may be sufficient magnitude to constitute a risk of electrical shock to people.
The exclamation mark is intended to alert the user of the presence of important operating and maintenance (servicing)
instructions in literature accompanying the appliance.
CAUTION
RISK OF ELECTRICAL SHOCK
DO NOT OPEN
ATTENTION
RISQUE DE CHOC ELECTRIQUE
CAUTION: T O AVOID THE RISK OF ELECTRICAL SHOCK.
DO NOT REMOVE COVER (OR BACK)
NE PAS OUVRIR
NO USER SERVICEABLE P ARTS INSIDE
WARNING:
THE ENCLOSURE HAS T O BE CHECKED UPON COLLISION DAMAGE; REFER
TO QUALIFIED SERVICE PERSONNEL
XPER MODULE MONITOR DO NOT HAVE APPLIED PARTS, AND ARE NOT INTENDED
TO BE CONNECTED TO A PATIENT CIRCUIT.
2
12” LCD
ProScribe Xper m
odule Atom
Safety and EMC approvals
The 12” LCD ProScribe Xper module Atom meets the following medical safety requirements:
DIRECTIVES
• MD – Safety Requirements: 2006/42/EC.
STANDARDS
• IEC 60601-1: 1988 + A1:1991 + A2:1995.
• EN 60601-1: 1990 +A1:1993 +A2:1995
• UL60601-1, 1st, 2006
• CAN/CSA-C22.2 No. 60601-1-M90, 2005
• IEC 60601-1: 2005
• EN 60601-1: 2007
• ANSI/AAMI ES 60601-1:2005
• CAN/CSA-C22.2 No. 60601-1:2008
The 12” LCD ProScribe Xper module Atom meets the following EMC a Radio requirements
DIRECTIVES
• R&TTE - Radio and Telecommunication Terminal Equipment: 1999/5/EC.
• EMF (Electromagnetic. Magnetic Field): EN 50392:2004
NOTE:
This equipment / system is intended for use by healthcare professionals only. This equipment / system may cause radio
interference or may disrupt the operation of nearby equipment. It may be necessary to take mitigation measures, such as
reorienting or relocating
the equipment / system or shielding the location.
RF EXPOSURE WARNING
This EUT is in compliance with MPE for general population / uncontrolled exposure limits and it had been tested in accordance
with the measurement methods and procedures specified in FCC 47 CFR § 1.1310 and 2.1091.
To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of 20 cm or more should be
maintained between the antenna of this device and persons during device operation.
To ensure compliance, operations at closer than this distance are not recommended. The antenna used for this transmitter must not
be co-located in conjunction with any other antenna or transmitter.
NOTE:
Even if this device has been certified according to medical standards requirements, the use of radio devices in specific clinical
environment may interfere or cause the malfunction of some medical equipment. Before using this device in a medical
environment, contact and ask permission to the local hospital authority.
3
12” LCD ProScribe Xper m
odule Atom
Biological Hazard and Returns
The structure and the specifications of this device as well as the materials used for manufacturing makes it easy to wipe and clean
and therefore suitable to be used for various applications in hospitals and other medical environments, where procedures for
frequent cleaning are specified.
However, normal use shall exclude biological contaminated environments, to prevent spreading of infections.
Therefore use of this device in such environments is at the exclusive risk of Customer.
In case this device is used where potential biological contamination cannot be excluded, Customer shall implement the
decontamination process as defined in the latest edition of the ANSI/AAMI ST35 standard on each single failed Product that
is returned for servicing, repair, reworking or failure investigation to Seller (or to the Authorized Service Provider). At least one
adhesive yellow label shall be attached on the top site of the package of returned Product and accompanied by a declaration
statement proving the Product has been successfully decontaminated.
Returned Products that are not provided with such external decontamination label, and/or whenever such declaration is missing, can
be rejected by Seller (or by the Authorized Service Provider) and shipped back at Customer expenses.
INTRODUCTION
The Philips 12” LCD ProScribe Xper module Atom, is a wireless smart display, released with Windows Embedded Standard
(WES), designed for medical applications.
The 12” LCD ProScribe Xper module Atom, is designed upon PMS CV requirements. It makes use of wireless technology and
thin-client computing to allow workers to access applications stored on a central server as if they were sitting behind their
desktop monitor. Its ruggedized design, compact size and touch-screen interface makes it also a perfect solution for point of
information and system control applications too.
.
Main features
With a 1.6 GHz Intel Atom N270 x86 processor as its engine and Microsoft Windows Embedded Standard as operation system,
the 12” LCD ProScribe Xper module offers a technologically powerful platform for mobile computing in enterprise applications.
Other main features are:
12.1 inch TFT-LCD with Touch-screen functionality;
1024x768 resolution (XGA);
display emulated keyboard;
integrated WiFi™ 802.11b/g/n PCIE Module wireless LAN - Built-in internal antenna.
lightweight (2,50 kg)
Rugged design for the toughest environments
The 12” LCD ProScribe Xper module Atom is compliant with industry standards for liquid (IP21) .
NOTE:
This Product has been designed to make it able to withstand certain mechanical stresses and/or to withstand exposure to harsh, wet
and dusty environment in accordance to the applicable industrial standards (IP grade). These measures are taken to enhance its
durability. However, it cannot be guaranteed that this Product will not be damaged when dropped or when subjected to liquid spill
or alike. Therefore the user is required to take appropriate care of the Product and to apply the following recommendations:
1. Do not drop the Product, do not hit the touch screen and do not place heavy objects on the Product
2. Do not expose the Product to moisture, dust and liquid sprays;
3. Do not scratch the touch screen with sharp edges and only use the provided tools (stylus pen);
4. Use a dry soft cloth to clean the Product and, specifically, the touch screen;
5. Do not use the Product in environments exceeding the specified temperature and humidity range
4
12” LCD
ProScribe Xper m
odule Atom
Easy to integrate, deploy and maintain
The 12” LCD ProScribe Xper module Atom allows users to take full benefit of thin-client computing where data and
applications are kept on a server where they can be managed centrally, more securely and at lower total cost. Nearly no
downtime is incurred in case a device is lost or stolen: a new 12” LCD ProScribe Xper module Atom straight from the box
allows a user to resume an interrupted login session exactly as before.
Server access is provided by one of the two pre-installed thin clients, Microsoft Remote Desktop Protocol (RDP), or Internet
Explorer.
.
Flexible to fit any vertical application
The 12” LCD ProScribe Xper module Atom offers a full suite of utilities and multiple plug-and-play interfaces for easy
integration into any type of environment, and specifically:
- Full-size XGA resolution: 1024 x 768
- Basic version with 1GB RAM and 4GB compact flash memory
- Two USB ports
- An 100Mbps RJ-45 Ethernet interface
Approved for medical applications
The 12” LCD ProScribe Xper module Atom meets the medical safety, EMC and Radio requirements.
For more details see “Safety and EMC approvals” chapter.
5
12” LCD ProScribe Xper m
odule Atom
CONTENTS
1. TECHNICAL INFORMATION ........................................................................................................ 8
4.1. RIGHT VIEW ........................................................................................................................................................... 10
4.2. LEFT VIEW .............................................................................................................................................................. 10
4.3. BACK VIEW ............................................................................................................................................................ 11
5. CONTROL PANEL DESCRIPTION ............................................................................................. 12
6. BEFORE YOU BEGIN .................................................................................................................... 13
7. GETTING STARTED ...................................................................................................................... 13
7.4. SET DATA AND TIME ............................................................................................................................................. 14
8. DATA INPUT TO THE TOUCH SCREEN..................................................................................... 15
8.1. TOUCH THE SCREEN ............................................................................................................................................ 15
8.2. RIGHT CLICK EMULA TION ................................................................................................................................. 15
9.2. LAN CONNECTION ................................................................................................................................................. 19
10. FEATURED SOFTWARE APPLICATIONS............................................................................. 21
10.1. CONTROL PANEL .................................................................................................................................................. 21
12.1. THE 12” LCD ProScribe Xper module Atom WILL NOT TURN ON... ................................................................. 23
12.2. MY SYSTEM DOES NOT RUN SMOOTHLY ........................................................................................................ 23
12.3. HOW DO I TURN OFF MY 12” LCD ProScribe Xper module Atom .................................................................... 23
12.4. WHEN I USE THE STYLUS PEN... ........................................................................................................................ 23
13. SAFETY AND PRODUCT CARE INSTRUCTIONS................................................................. 24
13.1. CLEAN THE SCREEN: ........................................................................................................................................... 24
13.2. CLEAN THE CASE: ................................................................................................................................................ 24
15. DISPOSAL OF THE LCD 12” LCD PROSCRIBE XPER MODULE ATOM.......................... 26
15.1. Dispose of coin battery inside of the 12” LCD ProScribe Xper module Atom (Mounted on .................................. 26
main board) : ......................................................................................................................................................................... 26
17. SYMBOL DESCRIPTION ........................................................................................................... 28
18. Annex 1: Susceptibility parameters to noise of EUT in the environment in which it operates ............................... 29
7
12” LCD ProScribe Xper m
odule Atom
1. TECHNICAL INFORM ATION
Processor Intel Atom N270 1.6 GHz
Chipset Intel 945GSE + 82801G (ICH7-M)
Graphic Processor Intel GMA945
BIOS Phoenix Award BIOS
Operating System Intel Microsoft Windows Embedded Standard with SP3
Networking Built-in 802.3 network card (Realtek RTL8111DL)
Built-in 802.11 b/g/n Wireless PCIE module with internal antenna
Model number: RTL8188CE
Model name: AW-NE139H
Bands transmission:
Europe 2413 ~ 2472 MHz
U.S. and Canada 2413 ~ 2462 MHz
Modulation:
DSSS (for IEEE 802.11b)
OFDM (for IEEE 802.11g)
Remote Protocol Microsoft RDP
Memory 1GB DDR2 SODIMM RAM
Local Storage 4GB PATA Compact Flash Module
LCD Panel Characteristic 12.1 “ TFT LCD with XGA 1024 x 768 resolution , LVDS I/F
(NEC NL10276BC24)
Audio System High Definition Audio Interface (Realtek ALC262)
Internal mono microphone
Internal stereo speakers
Durability Rugged anti-shock design with standing 1 meter drop
IP21 water and dust resistant construction (front side)
PAD I/O • 2 x USB ports
• 1 x D-SUB 9 pins which supports Ethernet signals and power DC in
LED indicator • 1 x WLAN LED
• 1 x Power green LED (ON / OFF status)
Buttons and Controls • 4 x hot keys (three of which are user programmable)
• 1 x Reset button
• 1 x Track pointer with 2 buttons (mouse emulation)
DC input rating DC In 24V (1A)
NOTE:
1 - WiFi and the WiFi logo are the registered trademarks of the Wi-Fi Alliance.
2 - Microsoft and Windows, Windows WES and Windows RDP are registered trademarks of Microsoft Corporation
3 - All other trademarks and registered trademarks are property of their respective owners.
While unpacking the 12” LCD ProScribe Xper module Atom, inspect it and other package contents for shipping
damage that could cause a fire or shock hazard. Immediately report any shipping damage to the carrier or
transportation company and contact customer service for assistance. Keep all packing material in case you need to
ship, store or return the device.