1.1 Intended use
1.2 Function
1.3 Technical data
1.4 Materials
1.5 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04
2. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04
2.1 Preparing for use
2.2 Mechanical connection
2.3 Electrical connection
3. Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05
3.1 Commissioning
3.2 Normal operation
3.3 Inexpert handling
4. Maintenance, servicing and spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05
4.1 Maintenance
4.2 Servicing
4.3 Spare parts
5. Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05
6. Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05
Flow switch
for liquids
Operating
Instructions
Page 2
Read these Safety Instructions before using the switch for the first time and follow the Operating instructions.
Safety instructions
1. The installation, initial operation and maintenance should only be carried out by a qualified expert with electrical know-how.
2. Comply with the local and statutory rules and/or the VDE0100.
3. Before electrical connection, check the specifications on the data plate and the technical data of this manual.
4. A fuse must be connected in series to the supply voltage, according to the Standard and Normative documents.
5. Protect the signal contacts of the limit switch against voltage peaks when inductive or capacitive loads are connected.
6. The device may be put into operation only if the electrical connection is correct. To secure the type of protection, the sealing cap and the gasket must be placed correctly.
7. The earth connection of the device has to be installed in such a way that mechanical damage will be excluded.
8. For a proper function, the paddle must not touch the pipe
9. For a proper function, the device must be installed in straigh pipes with a mininum length at least of five times the diameter and far from valves or
filters to avoid turbulence.
10. Switch off the power supply, before disconnecting the device.
and it is necessary to ensure the free movement of the paddle.
LIT-2, LIT-VL, LIT-VP, LIT-VT and LIT-VTM
02 Talleres Filsa, S.A.U. www.filsa.es E-08100 Mollet del Vallès (Barcelona) Tel. +34 93 570 46 01 Fax +34 93 570 24 71 filsa@filsa.es
10/15 © by FILSA MI-LIT2LITV-EN-02
Page 3
Operating instructions
1. Specification
1.1 Intended use
The flow switches are used to control the flow of waters, oil, chemical products, etc. through the device.
Depending on the model, it can be controlled a range flow from 0.5 l/min up to 24 l/min.
1.2 Function
Depending on the model, there is a paddle or a free movement system inside the device.
1.3 Technical data
Manufacturer Talleres Filsa, S.A.U.
Address Bernat Metge, 33
08100 Mollet del Vallès (Barcelona)
Name Flow switch
Type LIT-2 3/8" ref: 2606
LIT-2 1/2" ref: 2606-1
LIT-2 3/4" ref: 2606-2
LIT-2 1" ref: 2606-3
LIT-VL ref: 2606-4
LIT-VP ref: 2606-5
LIT-VT ref: 2606-6
LIT-VTM ref: 2606-7
Maximum pressure
Cable output
2 wires x 2 meters
2 wires x 0.5 meters
When the liquid flow of the pipe pulls the paddle actuates a microswitch or a REED switch depending on the model. There are models with different proccess connections and made of differents materials to can control the flow in a wide range of applications.
LIT-2 +25 bar
LIT-V... +10 bar (+20 ºC)
LIT-2 DIN 43650 connector
LIT-VL and LIT-VP
LIT-VT and LIT-VTM
Maximum voltage 250 V AC
LIT-2 250 V AC
LIT-VL 250 V AC and 200 V DC
LIT-VP 250 V AC
LIT-VT and LIT-VTM 250 V AC and 200 V DC
Contact function 1 NO + 1 NC
LIT-2 contact
LIT-VL contact
LIT-VP contact
LIT-VT and VT-M contact
Protection IP65 according DIN EN60529
For capacitive or inductive loads reduce at
For capacitive or inductive loads reduce at
For capacitive or inductive loads reduce at
For capacitive or inductive loads reduce at
Weight
0.30 kg
0.30 kg
0.35 kg
0.39 kg
0.36 kg
0.14 kg
0.07 kg
1.4 Materials
ABS
Body
Brass
Noryl
Cupper
Paddle or contact material
Stainless Steel
Noryl
LIT-V... cable Double insulation
Double insulation
Capacity of the contact 5 A / 250 V AC
(resistive load)
50%
Max. power consumption 40 VA in AC; 40 W in DC
Contact current 1 A (resistive load)
50%
Contact current 1 A (resistive load)
50%
Max. power consumption 40 VA in AC; 40 W in DC
Contact current 1 A (resistive load)
50%
Temperature range
LIT-2 -20 °C ... +110 °C
LIT-VL -30 °C ... +100 °C
LIT-VP, LIT-VT and LIT-VTM -30 °C ... +85 °C
LIT-2 3/8"
LIT-2 1/2"
LIT-2 3/4"
LIT-2 1"
LIT-VL
LIT-VP
LIT-VT and LIT-VTM
LIT-2 housing
LIT-2 and LIT-VL
LIT-VP
LIT-VT and LIT-VTM
LIT-2
LIT-V...
PVC
LIT-VL and LIT-VP Single inulation PVC
LIT-VT and LIT-VTM PVC
LIT-2, LIT-VL, LIT-VP, LIT-VT and LIT-VTM
Talleres Filsa, S.A.U. www.filsa.es E-08100 Mollet del Vallès (Barcelona) Tel. +34 93 570 46 01 Fax +34 93 570 24 71 filsa@filsa.es 03
10/15 © by FILSA MI-LIT2LITV-EN-03
Page 4
2. Installation
-
-
The switch has to be insterted between a pipe welding the device or using proccess accesories depending on the model.
The models LIT-2 and LIT-VT can be side or vertically mounted due to a return spring meanwhile the others has to be inserted vertically. The indication arrow in the body has to be faced to the flow.
- Fasten the DIN connector after making the electrical connection.
- Fix and fasten the screw of the DIN connector to ensure the water-tightness.
2.1 Preparing for use
For a proper function, the device must be installed in straigh pipes with a mininum length at least of five times the diameter and far from valves or filters to avoid turbulence.
Read the Safety Instructions and the Operation Instructions before
using the controller.
2.2 Mechanical connection
2.3 Electrical connection
Connection diagram
LIT-2
LIT-V...
Output 2 wires, NC with flow.
DIN connector
Cable connections
Connections must be safe and water-tight. The connections should be out of the tank.
1.5 Dimensions
Approximate measures are given in mm.
LIT-2
LIT-VL
LIT-VP
LIT-VT y LIT-VTM
LIT-2, LIT-VL, LIT-VP, LIT-VT and LIT-VTM
04 Talleres Filsa, S.A.U. www.filsa.es E-08100 Mollet del Vallès (Barcelona) Tel. +34 93 570 46 01 Fax +34 93 570 24 71 filsa@filsa.es
10/15 © by FILSA MI-LIT2LITV-EN-04
Thread
H
3/8 "
83
1/2 "
83
3/4 "881 "
90
H
50
109
45.5
40
32
Biconical 22 mm
Biconical 22 mm
37
16
35
Ø 22
Ø 30
Ø 12
Ø 42
17.5
16
10
43.5
18
Male thread G 3/4 "x15
Ø 23
35
Ø 15
25
23
44 73
35
26
14
30
Female thread G 3/4 "x15
36
LIT2LITV-001
LIT2LITV-002
LIT2LITV-003
LIT2LITV-004
1
3
2 4
[
Terminal
1 2 3 4
Contact
NO Common C NC
LIT2LITV-005
LIT2LITV-006
32
Page 5
Sensitivity adjustment
- The flow switches LIT-VL/VP/VT switch with a fix flow of 1 l/min.
- The flow switche LIT-VTM switchs with a fix flow of 0.5 l/min.
- The flow switch LIT-2 has a regulation system that allows the adjustment of the sensitivity. Open the cap in the back of the device body and turn the screw to reduce the sensitivity and increase the strain of the flow to activate the microswitch. Unterclockwise insensitive. The device is adjusted at the maximum sensitivity.
- The range of flow can be consulted in the following table (LIT2LITV-008)
* Tolerance ± 15% scale range.
Minimum hysteresy 0.7 l/min.
3. Use
3.1 Commissioning
- Put the controller into operation only if the installation and the
electrical connection have been done correctly.
3.2 Normal operation
- Use the device in its intended application only.
- Comply with the specifications
- If the controller is damaged, disconnect it immediately.
- It is forbidden to make changes to the device. This violates the Normative.
on the data plate and the technical
data of this manual.
3.3 Inexpert handling
- Ignoring the Safety instructions and the Operating instructions.
- Not intended use.
- Making changes or handling the flow switch.
- Violation against applicable Law and Standards.
- Using of non original parts.
4. Maintenance, servicing and spare parts
4.1 Maintenance
- If used correctly, no specific maintenance is required.
4.2 Servicing
- Check and review the state of the housing and the correct commutation of the electrical contact, as well.
4.3 Spare parts
- There are no spare parts for these controllers.
5. Storage
- Store the controller in a dry and dust-free environment.
6. Disposal
-
- The controller can be recycled.
- The disposal applies to the valid environmental Guidelines according to the location of the carrier and the local manufacturing conditions.
Switch off the power supply, before disconnecting the device.
LIT-2, LIT-VL, LIT-VP, LIT-VT and LIT-VTM
Talleres Filsa, S.A.U. www.filsa.es E-08100 Mollet del Vallès (Barcelona) Tel. +34 93 570 46 01 Fax +34 93 570 24 71 filsa@filsa.es 05
10/15 MI-LIT2LITV-EN-05 © by FILSA
Diameter of pipe
Flow range
G ”
l/min
3/8
5 ... 6
1/2
6 ... 7
3/4
7.5 ... 11
1
19 ... 24
LIT2LITV-008
More flow needed to activate the signal.
Less flow needed to activate the signal.
LIT2LITV-007