APPLICABILITY & EFFECTIVITY
Effective for all systems manufactured after October 2011
Driver Manual
(Supplement to the FieldServer Instruction Manual)
FS-8700-113
X30 Profibus DP Slave)
A Sierra Monitor Company

FS-8700-113_Profibus_X30_DP_Slave Driver Manual Table of Contents
TABLE OF CONTENTS
1 Profibus X30 DP Slave Description ................................................................................................................. 3
1.1 Max Nodes Supported ................................................................................................................................... 3
2 Driver Scope of Supply ................................................................................................................................... 3
2.1 Supplied by FieldServer Technologies for this driver ..................................................................................... 3
2.2 Additional files Required for the Driver ......................................................................................................... 3
2.3 Provided by the Supplier of 3rd Party Equipment .......................................................................................... 3
2.3.1 Required 3rd Party Software ................................................................................................................... 3
2.3.2 Required 3rd Party Configuration ........................................................................................................... 3
3 Hardware Connections ................................................................................................................................... 4
3.1 Hardware Connection Tips / Hints ................................................................................................................. 4
4 Data Array Parameters ................................................................................................................................... 5
5 Configuring the FieldServer as a Profibus DP Server ....................................................................................... 6
5.1 Profibus Settings ............................................................................................................................................ 6
5.2 Server Side Connection Parameters .............................................................................................................. 7
5.3 Server Side Node Parameters ........................................................................................................................ 7
5.4 Server Side Map Descriptor Parameters ........................................................................................................ 8
5.4.1 FieldServer Specific Map Descriptor Parameters ................................................................................... 8
5.4.2 Driver Specific Map Descriptor Parameters ........................................................................................... 8
5.4.3 Map Descriptor Example. ....................................................................................................................... 9
Appendix A. Useful Features ................................................................................................................................ 10
Appendix A.1. X30 Profibus LED indicators ............................................................................................................. 10
Appendix A.2. Setting the FieldServer’s Profibus Station Address .......................................................................... 11
Appendix A.3. Understanding Driver Communication Statistics ............................................................................. 11
Appendix B. Troubleshooting ............................................................................................................................... 12
Appendix B.1. Communication Problems ................................................................................................................ 12
Appendix C. Vendor Information ......................................................................................................................... 14
Appendix C.1. Using the Siemens PLC with the Anybus Card .................................................................................. 14
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com

FS-8700-113 X30 Profibus DP Slave Driver Manual Page 3 of 14
The FieldServer can only emulate one Profibus DP Slave station
FieldServer Technologies PART #
Adapter Card, Anybus-S Profibus DP
Template loaded if no custom configuration ordered, otherwise Custom configuration loaded.
The Anybus template gsd file is supplied with the FieldServer and needs to be built up for the
particular application by the Master configuration software
1 PROFIBUS X30 DP SLAVE DESCRIPTION
The FieldServer Profibus DP Slave driver can be used to emulate a single Slave station on a Profibus network. DP
Masters can open a connection of up to 244 Bytes of Input and 244 Bytes of Output data, but not exceeding a
combined total of 416 Bytes to the FieldServer. The FieldServer can be added to the Profibus network with the use
of the supplied GSD file for the ANYBUS card. Connection to the Profibus network is via a DB9 port on the
ANYBUS card.
1.1 Max Nodes Supported
2 DRIVER SCOPE OF SUPPLY
2.1 Supplied by FieldServer Technologies for this driver
2.2 Additional files Requir ed for the Driver
2.3 Provided by the Supplier of 3
2.3.1 Required 3
Profibus Network Configuration Tool
2.3.2 Required 3
Connection to a properly terminated Profibus network.
rd
Party Software
rd
Party Configuration
rd
Party Equipment
1
Always Loaded By FieldServer Technologies
2
External Application
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com

FS-8700-113 X30 Profibus DP Slave Driver Manual Page 4 of 14
Profibus DB9 connector
NetTool RS-232 connector
Profibus Status LEDs
HMS Anybus NetTool RS-232 Serial Cable
Positive RxD/TxD according to RS-485 specification
Isolated GND from RS-485 side
Isolated +5V from RS-485 side
Negative RxD/TxD according to RS-485 specification
FieldServer Side DB9 Female
3 HARDWARE CONNECTIONS
The FieldServer is connected to the Profibus network and NetTool as shown in the connection drawing below.
Profibus DB9 Connector Pinouts
Only A-line, B-line and Shield are used for most applications.
Profibus NetTool connector Pinouts
3.1 Hardware Connection Tips / Hints
Use the recommended network cable and terminators as specified by the Profibus network organization and/or
the manufacturer of your network equipment.
3
Used in some equipment to determine the direction of transmission.
4
Used for bus termination. Some devices, e.g. optical transceivers (RS-485 to fiber optics) require an external power supply from these pins.
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com

FS-8700-113 X30 Profibus DP Slave Driver Manual Page 5 of 14
Provide name for Data Array
Up to 15 alphanumeric characters
Provide data format. Each Data Array can only take
on one format.
FLOAT, BIT, UInt16, SInt16,
Packed_Bit, Byte, Packed_Byte,
Swapped_Byte
Number of Data Objects. Must be larger than the
data storage area required by the Map Descriptors
for the data being placed in this array.
4 DATA ARRAY PARAMETERS
Data Arrays are “protocol neutral” data buffers for storage of data to be passed between protocols. It is necessary
to declare the data format of each of the Data Arrays to facilitate correct storage of the relevant data.
Example
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com