Field Controls 46448400, UV-AIRE UV-1500C User Manual

Page 1
UV-AIRE™ AIR PURIFYING SYSTEM
Model: UV-1500C
ITEMS INCLUDED IN KIT:
1-UV-Aire UV-1500 units 10-Sheet metal mounting screws 2-drop ceiling cover plates 4-Wall and drop ceiling mounting
brackets 1-Ultra Violet lamp 1-Instruction Sheet 1-2x4 Electrical Conduit Box and Cover 4-Intake Air Filters 1-Carbon Filter
*For best results, operate the UV-1500 continuously 24 hours a day.
UV-C light inhibits the growth and reproduction of germs and bacteria in the air of a home or office. The treatment is a safe, silent, and proven way to make your home or office a healthier place to live and work.
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION
LEAVE THE INSTALLATION INSTRUCTIONS WITH THE OWNER/OPERATOR OF THE DEVICE
AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE.
DO NOT INSTALL THIS UNIT IF ANY DAMAGE IS NOTICEABLE.
WARNING: Never expose eyes or skin to UVC light from any source.
Looking directly at the UVC light may cause permanent eye damage or blindness.
Never operate the UV-Aire™ Air Purifying System with the UV chamber open.
WARNING: DO NOT mount this unit outdoors.
This product is designed for indoor installation only.
Page 2
I. INDICATION FOR USE
r
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation, treatment, or prevention of any disease or condition.
II. GENERAL INFORMATION
Model Volts Amps
UV-1500C 120 1.3 60 130
Hz
Watts
Lamp Intensity
at 1 meter
37 μW/cm
2
Recommended
Max Sq. Feet
1500 15.5 Lbs 18 23-3/4 6-5/16
Weight
Width
(Inches)
Height
(Inches)
WARNING: This product is designed for indoor installation only.
The UV-1500C is designed as a multipurpose room air purification system. The unit can be placed in a room sitting on the floor, it can be mounted on the wall to maximize floor space or it can be mounted into a suspension (drop) ceiling.
Depth
(Inches)
F
EATURES
1. The UV-1500C is equipped with a speed control to allow the user to adjust the airflow through the unit from 35 cfm to 100 cfm.
2. The UV-1500C has a safety shut off switch that disconnects power to the fan and the lamp if the front access door is opened.
3. The UV-1500C is equipped with a circuit board to monitor the operation of the UV lamp; it indicates the operation of the lamp through a LED indicator light mounted on the front access door. The circuit board indicates good operation of the lamp by a continuous “GREEN” color on the LED light. After 8320 hrs of lamp operation, the circuit board indicates the elapsed time of lamp operation by a continuous “YELLOW” color on the LED light and the internal alarm will beep every 15 minutes. After 9000 hrs of lamp operation, the circuit board indicates the elapsed time of lamp operation by a continuous “RED” color on the LED light and the internal alarm will beep every 5 minutes. The board also checks if the UV lamp is burned out. The circuit board will indicate this by a continuous “RED” color on the LED and the internal alarm will beep every 5 minutes.
III. UV-1500C CHECK OUT PROCEDURE
1. Plug the power cord into a standard 120-volt wall receptacle.
2. Turn the speed control knob clockwise to turn the unit on. After the fan has started, the LED light will show a continuous “GREEN” color indicating proper unit operation.
3. Once you have determined that the unit is functioning properly, turn unit off and unplug.
4. Continue to next section for mounting options.
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage o blindness. Never operate the UV-Aire™ Air Purifying System with the UV chamber door ope n. Avoid touching the glass portion of the lamp with your hands.
Page 2
Page 3
IV. FOR AREA OR ROOM OPERATION
1. Place the UV-1500C in the desired area; plug the power cord into a standard 120-volt wall receptacle.
2. Turn the speed control knob clockwise to turn on the unit and to adjust the motor/fan speed to the desired airflow. (See Figure 1)
3. After the fan has started, the LED light will show a continuous “GREEN” color indicating proper unit operation.
V. WALL MOUNTING OPTION (The UV-1500C is supplied with four mounting brackets to allow
the unit to be mounted onto a wall)
1. To install the mounting brackets, remove the eight mounting screws from the back of the UV-1500C shown in Figure 2.
2. Install the four mounting brackets onto the back of the housing securing them with the mounting screws you just removed. (See Figure 3)
3. Determine the desired location on the wall (a 120-volt wall receptacle should be within 5 feet of the unit) and mark the mounting screw locations based on the dimensions given in figure 4A.
4. Install four drywall anchors or other appropriate fasteners rated for at least a 15 lbs load capacity. (See Figure 4B)
5. Mount the unit to the wall. (See Figure 5)
6. Plug the power cord into a standard 120-volt wall receptacle. Turn the speed control knob clockwise to turn on the unit and adjust the motor/fan speed control to the desired airflow.
7. After the fan has started the LED light will show a continuous “GREEN” color indicating proper unit operation.
Figure 1
Mounting
Screws
Figure 3
Figure 2
VI. SUSPENSION OR DROP CEILING OPTION
The UV-1500C must be wired in accordance with the National Electrical Code and any applicable local codes. The UV-1500C must be hard-wired using metal-shielded cable, BX cable or othe r similar wiring methods.
1. Install the four mounting brackets onto the back of the housing securing them with the eight mounting screws (See Figure 2 & 3).
2. Mount the supplied drop ceiling body extension covers onto the sides of the UV-1500C. These covers allow the UV-1500C to fit into a standard 2 foot by 2 foot ceiling tile space (23-3/4”). Align the edges of the extension cover to the front of the UV-1500C body and use the holes in the cover as a template to mark the mounting hole locations on the UV­1500C body. (See Figure 7)
Figure 4A
Figure 5
Figure 6
Figure 4B
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or
blindness. Never operate the UV-Aire™ Air Purifying System with the UV chamber door ope n. Avoid touching the glass portion of the lamp with your hands.
Figure 7
Page 3
Page 4
3. Drill a 1/8” hole into the body of the UV-1500C at the marked locations. (See Figure 8)
r
g
4. Secure the extension covers the UV-1500C body with the supplied metal screws (See Figure 9 & 10).
5. Remove the two rubber feet on the side of the extension cover from bottom of unit to give necessary clearance for ceiling mount. (See Figure 11)
Figure 8
Figure 11
Figure 9
Figure 10
6. Before hard wiring the UV-1500C, an electrical conduit box must be installed. Remove the wire cover in the back of the unit. Uninstall the wire nuts and discard the power cord. (See Figure 12).
7. Mount the supplied electrical conduit box over the power wires and secure with the supplied mounting screws. (See Figure 13)
Figure 12
Figure 13
8. Locate and remove the ceiling tile where the UV-1500C will be mounted.
9. Install eyelet screws or other appropriate anchors into the ceiling joists above the location where the will be installed. If installing the UV-1500C into 4-foot by 2-foot title grid, install an additional suspended ceiling tee bracket into the ceiling grid to form a 2-foot by 2-foot title location. (See Figure 14)
10. Install the UV-1500C into the suspended ceiling grid then install support wires (16 gauge wire) or other suspended ceiling support method between the installed ceiling anchors and the four mounting brackets on the back of the UV-1500C. (See Figure 15)
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage o blindness. Never operate the UV-Aire™ Air Purifying System with the UV chamber door ope n. Avoid touching the glass portion of the
lamp with your hands.
Figure 14
Page 4
Support Wire
Fi
ure 15
Page 5
11. Wire the UV-1500C in accordance with the National Electrical Code, manufacturer's recommendations and/or
r
applicable local codes. UNIT MUST BE GROUNDED. Check ground circuit to make certain that the unit has been properly grounded. The wiring should be protected by an over current circuit device rated a t 15 amperes. R efer to Diagram A for wiring.
11. Place cover over conduit box. (See Figure 16)
12. Apply power to the UV-1500C. Turn the speed control knob clockwise to turn on the unit and adjust the motor/fan speed control to the desired airflow. After the fan has started the LED light will show a continuous “GREEN” color indicating proper unit operation.
VII. MAINTENANCE
1. Replace 12”x 12” intake filter every 90 days, replace carbon outlet filter every 12 months.
2. Replace your UV-Aire™ Air Purifying System lamp once a year to maintain the lamps maximum output intensity. The lamp should operate continuously for maximum lamp life and light effectiveness.
VI. REPLACEMENT PROCEDURES
R
EPLACING THE UV LAMP
VERY IMPORTANT: Turn the speed control switch on unit to ‘OFF’ position and unplug unit from outlet or turn off
power to the unit before replacing the UV lamp.
1. Loosen the two door-mounting screws on front cover of the UV-1500C. (See Figure 17)
2. Open the cover to expose the filters and the air purification chamber (See Figure 18).
Diagram A
Figure 16
3. Rotate the two door clips to allow the chamber access door to open (See Figure 19).
4. Unplug ballast plug from end of lamp and loosen the wing nut on swivel bracket. Swing swivel bracket away
from the lamp (See Figure 20).
Door Mounting
Screw
Figure 17
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage o
blindness. Never operate the UV-Aire™ Air Purifying System with the UV chamber door ope n. Avoid touching the glass portion of the lamp with your hands.
Figure 18
Page 5
Door Clips
Figure 19
Figure 20
Page 6
5. Remove lamp carefully, by sliding the lamp to the left through the hole on the left side of the chamber. After
r
exposing the connection end of the lamp inside the chamber, remove the lamp through the front of the unit.
NOTE: When replacing the lamp, always wipe off lamp with the supplied alcohol wipe after installing.
6. Replace the lamp by first guiding the end of the lamp through the hole on the left side of the UV chamber.
Next, guide the other end of the lamp through the hole on the right side of the UV chamber. Hold the lamp in position while rotating the swivel bracket into position. Secure the lamp into position by tightening the wing nut onto the swivel bracket.
NOTE: UV lamps contain a small amount of mercury, like a typical fluorescent lamp. Check with your local waste
management authority for local disposal or recycling requirements. According to the EPA’s Universal Waste Rule, these types of lamps may be disposed of into household waste.
7. Close the Chamber access door and rotate the door clips to secure the door into position. WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause
permanent eye damage or blindness.
8. Plug the power cord back into the wall receptacle or restore power to the UV-
1500C circuit.
Reset Button
9. Turn the knob on the speed control to the on position, press the door switch in,
and allow the motor to start and the lamp to light. Wait 30 seconds.
10. Reset the lamp timer by using the eraser end of a pencil or the blunt end of a
plastic ink pen and press and hold the timer-reset button on the circuit board for 30-45 seconds (See Figure 21). After releasing the timer-reset button the LED on the front of the unit will flash twice indicating the timing circuit has been reset.
11. Release the door switch, turn the knob on the speed control to the off position and
close the front cover of the unit. Secure the cover with the door mounting screws.
12. Turn the speed control knob clockwise to turn on the unit and adjust the motor/fan
speed control to the desired airflow. After the fan has started the LED light will show a continuous “GREEN” color indicating proper unit operation
R
EPLACING AIR FILTERS
1. Loosen the two door-mounting screws on front cover of the UV-1500C. Open the cover to expose the filters
and the air purification chamber. (See Figure 17)
2. Replace the 12” by 12” air filter by removing the filter and replacing the filter with the wire support side of the
filter installed toward the fan intake of the unit. (See Figure 18)
3. Replace the carbon filter by removing the old filter and inserting the new filter back into the filter holder.
VII. TROUBLESHOOTING GUIDE
1. If the LED is illuminating a “YELLOW” color and the circuit board alarm beeps every 15 minutes, then the lamp should be replaced soon.
2. If the LED is illuminating a “RED” color and the circuit board alarm beeps every 5 minutes, then the lamp should be replaced.
3. If lamp does not light up replace lamp.
4. If lamp still does not light up after replacing the lamp, replace ballast.
VIII. REPLACEMENT PARTS LIST
Figure 21
LAMP BALLAST
(Field Controls Part Number)
46365401
For replacement parts, contact your local heating service company. Any questions, please contact Field Controls at:
Phone: 252-522-3031 Fax: 252-522-0214 Email: sales@fieldcontrols.com
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage o blindness. Never operate the UV-Aire™ Air Purifying System with the UV chamber door ope n. Avoid touching the glass portion of the
lamp with your hands.
(Field Controls Part Number)
46365514
Page 6
YEARLY FILTER AND
LAMP REPLACEMENT KIT
(Field Controls Part Number)
46453600
Page 7
r
WARRANTY INFORMATION
ONE YEAR LIMITED WARRANTY (excluding lamps, which have a 90 day warranty, from day of installation)
The products of The Field Controls Co. are warranted to be free from defects in material and workmanship under normal use for one (1) year from date of purchase. In the event of malfunction or failure of this product, the purchaser shall properly package the entire unit and ship it PREPAID with return address to th e address listed below. At the time of request for warranty service, the purchaser must present proof of purchase documentation which includes the date of purchase (for example, a receipt or sales slip). If the malfunction or failure is a result of defects covered by this warranty, Field will, at its option, repair the product or replace it and return it to the purchaser.
This warranty is limited to the original retail purchaser and is not transferable. The warranty does not cover damage due to accidents, abuse, tampering or misuse, nor does it cover damage resulting from service persons other than Field. Field’s liability under this warranty is expressly limited to the repair, replacement, or
refund of the invoice price of products, which prove to be defective in material or workmanship within a period of ninety days from date of purchase. Field’s obligation to repair or replace defective products or refund of invoice price constitutes agreed and liquidated damages for any breach of warranty by Field.
FIELD’S LIABILITY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF A DEFECTIVE PRODUCT WITH THE EX CEPTION OF DAMAGES RESULTING FROM FIELD’S FAILURE TO COMPLY W ITH FEDERAL OR STATE WARRANTY LAW. FIELD SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, WHETHER DIRECT OR INDIRECT.
THIS WARRANTY IS EXPRESSLY GRANTED IN LIEU OF ALL OTHER W ARRANTIES INCLUDING BUT NOT LIMITED TO, THE IMPLI ED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Some states may not allow the exclusion or limitation of incidental or consequential damages, or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific rights and you may also have other rights which vary from state to state.
In the event you have any questions concerning the use and care of your Field product or concerning service under this warranty or otherwise, please write: The Field Controls, L.L.C. 2630 Airport Rd., Kinston, N.C. 28504.
The health aspects associated with the use of these products and their ability to aid in disinfecting of environmental air have not been investigated by UL.
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage o blindness. Never operate the UV-Aire™ Air Purifying System with the UV chamber door ope n. Avoid touching the glass portion of the lamp with your hands.
Page 7
Page 8
Page 8
P/N 46448400 Rev D 09/05