UV-AIRE® AIR PURIFYING SYSTEM
Model: UV-500C
*For best results, operate
the UV-500 continuously 24
hours a day.
8" germicidal UV lamp
10"x10" high-efficiency/carbon filter
Heavy-duty three speed fan
Visual lamp and filter condition
Adjustable fan control
Built in handles for easy portability
Non-skid rubber feet
ITEMS INCLUDED IN SYSTEM:
1- UV-Aire UV-500C unit
1- Ultra Violet Lamp Individually Boxed
1- Instruction Sheet
4- 10"x 10"x 1" Filters
1- Bagged Parts: containing lamp connector,
alcohol swab and access door screw
UV-500C Features
The high intensity ultraviolet light attacks airborne mold, bacteria, and viruses. The high efficiency filter traps
allergens, dust, and pollen. The carbon filter removes odors and attacks VOCs (volatile organic compounds).
LEAVE THE INSTALLATION INSTRUCTIONS WITH THE OWNER/OPERATOR OF THE DEVICE.
AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE.
DO NOT INSTALL THIS UNIT IF ANY DAMAGE IS NOTICEABLE.
SAFETY CONSIDERATIONS
WARNING: Never expose eyes or skin to UVC light from any source.
•LookingdirectlyattheUVClightmaycausepermanenteyedamageorblindness.
•NeveroperatetheUV-AireAirPurifyingSystemwiththeUVlampaccessdooropen.
WARNING: DO NOT mount this unit outdoors.
•Thisproductisdesignedforindoorinstallationonly.
WARNING: To avoid electrical shock hazard, do not operate in wet environment.
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for
use in the mitigation, treatment, or prevention of any disease or condition.
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.
This device MUST be installed by a qualified agency in accordance with the manufacturer's installation instructions. The definition of
a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged
in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the
precautions required, and has complied with all the requirements of the authority having jurisdiction.
Please retain these instructions after installation.
Installed By: Phone:
Installation Date:
www.fieldcontrols.com

INDICATION FOR USE
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or
condition nor for use in the mitigation, treatment, or prevention of any disease or condition.
GENERAL INFORMATION
Model Volts Amps Hz Watts
UV-
500C
120 .4 60 38 15µW/cm
Lamp Intensity
at 1 meter
Recommended
Max. Sq. Feet
2
Weight
500 11 Lbs 12 15 13
FEATURES
The UV-500C is equipped with a three speed control to allow the user to adjust the airflow through the 1.
unit from 30 cfm to 70 cfm. Any speed is effective in rooms up to 500 square feet
The UV-500C is equipped with a circuit board to monitor the operation of the UV lamp and the 2.
operation time until the filter or lamp needs to be changed.
UV-500C SET UP PROCEDURE
Remove the lamp from the top carton pad. 1.
Remove the lamp connector from the bagged parts provided. 2.
Remove the UV-500C from its protective plastic bag. 3.
WARNING: DO NOT PLUG INTO WALL OUTLET!
Width
(Inches)
Height
(Inches)
Depth
(Inches)
Connect the UV lamp to the lamp connector knob. (See Figure 1) 4.
Figure 1
Clean the lamp with the alcohol swab provided. (See Figure 2)5.
NOTE: Dirt and fingerprints will reduce lamp output
and effectiveness.
Open the lamp access door on the back of the unit.6.
Figure 2
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.
Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
page 2

Insert the ceramic tip of the lamp into the UV port and twist the 7.
lamp connector clockwise to lock in place. (See Figure 3)
With unit still UNPLUGGED, insert the lamp power connector 8.
into the recessed receptacle on the unit. (See Figure 4)
Figure 3
Figure 4
Close the access door and install the access door screw 9.
provided in the bagged parts. (See Figure 5)
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.
Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
Figure 5