Field controls RB-1 User Manual

AIR BOOSTER
Model: RB-1
DO NOT DESTROY
READ AND SAVE THESE INSTRUCTIONS
English.......Page 1
Français .....Page 4
PRODUCT QUESTIONS…
CALL FIELD FIRST
for answers on product maintenance,
operation or replacement part questions.
Phone: (252)522-3031
E-mail:
fieldtec@fieldcontrols.com
WARNING: To reduce the risk of fire, electrical shock, or injury to persons, observe the following:
1. Use this only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
REGISTER OPENING HEIGHT “A” DIMENSION
VENT DIMENSION CHART
2-1/4” 1-1/4”
2. Before servicing or cleaning unit, unplug the RB-1 from the electrical outlet to prevent power from being switched on accidentally.
4” 1/4”
6” 1/4”
3. Do not use this fan with any solid-state speed control device.
This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.
GENERAL INFORMATION
The EVENAIR Register Booster is designed to increase the airflow through heated and cooled distribution ducts.
The EVENAIR should be installed on a supply duct register in rooms where there isn’t proper flow. The EVENAIR can only be put on registers that are smaller than 14” X 6.”
INSTALLATION INSTRUCTIONS T
YPICAL INSTALLATION INSTRUCTIONS
Figure 1
1. Find the register in the problem area.
2. If the register is on the floor, place the bottom of the EVENAIR over the register grating so that the EVENAIR completely covers it. Then plug it into a standard electrical outlet. Refer to adjustment and operation section.
F
IXED FLOOR MOUNTING OR WALL MOUNTING
1. Find the register in the problem area.
2. Measure up the distance A (See Figure 1) on the Vent Dimension Chart from the top of the register. Place the keyhole slots on the back of the EVENAIR (See Figure
Figure 2
2) at the distance A and the EVENAIR on the register making sure that the keyhole slots stay at the recommended distance. Put a mark in the spots where the keyhole slots are, drill two holes to fit number 8 screws, and insert the screws leaving enough room so that the keyhole slots can be placed over and slid under the screw heads.
3. Place the keyhole slots over the screws and slide them under so that they latch into place. Now plug the EVEVAIR into a standard electrical outlet. Refer to adjustment and operation section.
Page 2
ADJUSTMENT AND OPERATION NOTE: Please follow these steps carefully to assure maximum
performance and proper operation of the unit. When properly adjusted, the RB-1 fan should take 1-2 minutes to start once the furnace or air conditioner blower has begun running. It should also take 1-5 minutes to shut off after the blower stops, allowing for the residual heated or cooled air to be distributed into the room.
H
EATING SEASON ADJUSTMENT
1. Place the RB-1 over the register.
2. Plug the unit into a standard 110V outlet.
3. Move the season switch to the “winter” position. (See Figure 3)
4. Carefully turn the sensitivity knob (See Figure 3) clockwise using your thumb and forefinger until the knob stops turning. Be sure not to overturn the knob, as it will damage the unit.
5. Allow the furnace to cycle at least two times.
Figure 3
6. When the furnace blower shuts off, adjust the sensitivity by slowly turning the adjustment knob counter-clockwise until the fan on the RB­1 starts operating.
7. Slowly turn the adjustment knob clockwise until the RB-1 fan stops. Leave the knob in this position unless further adjustment is required.
8. Monitor the operation of the unit to make sure it is working properly.
C
OOLING SEASON ADJUSTMENT
1. Place the RB-1 over the register.
2. Plug the unit into a standard 110V outlet.
3. Move the season switch to the “summer” position. (See Figure 3)
4. Carefully turn the sensitivity knob counter-clockwise using your thumb and forefinger until the knob stops turning. Be sure not to overturn the knob, as it will damage the unit.
5. Allow the air conditioner to cycle at least two times.
6. When the blower shuts off, adjust the sensitivity by slowly turning the adjustment knob clockwise until the fan on the RB-1 starts operating.
7. Slowly turn the adjustment knob counter-clockwise until the RB-1 fan stops. Leave the knob in this position unless further adjustment is required.
8. Monitor the operation of the unit to make sure it is working properly.
NOTE: If the EvenAir Register Booster still isn’t working properly after all adjustments have been made, call us at 252- 522-3031 and we will be happy to assist you.