Field Controls DUO-11/24V, DUO-14/24V, PCUV-16UA User Manual

PHOTO-CATALYTIC AIR PURIFIER SYSTEMS
Models: DUO-11/24V, DUO-14/24V, PCUV-16UA
ITEMS INCLUDED IN KIT:
1-24Volt UV-Aire Ballast Assembly 1-Photo-Catalytic Duct Insert 1-UVC Germicidal Lamp 4-Sheet Metal Mounting Screws 1-Instruction Sheet 1-Duct Board Mounting Bracket 1-24V Transformer 2-Fork Terminals 2-Wire Nuts
The Duo 24V models produce germicidal UVC Band light rays, which sterilize and reduce airborne microorganisms and reduce Volatile Organic Compounds (VOC’s) by a photocatalytic chemical reaction as air passes through a heating or air conditioning system. It is installed in the main supply or return duct and operates continuously to automatically purify the air in the home 24 hours a day.
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or
condition, nor for use in the mitigation, treatment, or prevention of any disease or condition.
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY
BEFORE PROCEEDING WITH THE INSTALLATION.
WARNING: For use with 24V ONLY! Do not exceed voltage rating. Severe damage to device and or  re could result. Verify proper voltage.
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation, treatment, or prevention of any disease or condition.
This device MUST be installed by a quali ed agency in accordance with the manufacturer's installation instructions. The de nition of a quali ed agency is: any individual,  rm, corporation or company which either in person or through a representative is engaged in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the precautions required, and has complied with all the requirements of the authority having jurisdiction.
Please retain these instructions after installation.
Installed By: Phone:
Installation Date:
www. eldcontrols.com
SAFETY CONSIDERATIONS WARNING: Never expose eyes or skin to UVC light from any source.
• Looking directly at the UVC light may cause permanent eye damage or blindness.
• Never operate the UV-Aire Air Purifying System out of the plenum.
• Designed for a closed duct system. Do not mount near a supply or a return air opening.
• All duct openings in direct line of site of the UV light must be sealed with aluminum tape or equivalent sealing methods. WARNING: UV light will break down plastic materials not rated for UV exposure: (Examples: wire insulation,  ex duct, drain pans and humidi ers)
• The unit must be mounted at least 30" from the above stated type of materials.
• If it is necessary to mount the unit in direct line of site of these types of materials, they must be shielded with aluminum foil, aluminum foil tape, or sheet metal. WARNING: DO NOT mount this unit outdoors.
• This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, etc.). WARNING: Never touch broken lamp or internal contents of lamp. The lamp contains mercury.
• After opening the carton, unpack and inspect the unit and lamp for damage. Do not install this unit if any damage is noticeable. If lamp is damaged, cracked or broken, do not touch lamp or other contents in carton. Close carton and return to seller immediately.
• In case of accidental exposure to internal contents of lamp, wash hands and any other a ected skin area with mild detergent. Remove a ected clothing immediately. If skin surface is pierced, seek medical attention immediately.
NOTE: If you touch the glass of the lamp, you should wipe the glass clean with isopropyl alcohol and a lint free wipe. If the lamp is not cleaned, the  lm of hand oils causes a reduction in the light intensity.
WARNING: Before installing or servicing a humidi er, air  lter, HVAC system, or this unit, etc., always turn all power OFF and have unit unplugged. Electrical shock can cause personal injury or death. Never expose eyes or skin to direct UVC light from any source.
WARNING: To prevent water damage or electric shock, do not mount unit under a humidi er.
WARNING: This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, etc.). For use on gas  red, oil  red, electric and split system heat pump forced air systems.* This product is NOT designed to be mounted outside on gas  red or heat pump packaged units.** *Split system heat pumps are systems where the air handler and the air conditioning compressor are separate units. **Packaged units are systems where the air handler and the air conditioning compressor are built together and are installed outside of the building.
GENERAL INFORMATION The UV-Aire unit uses technology that is recommended by doctors who state that "ultraviolet radiation, properly integrated with heating, ventilating, and air conditioning systems, shows the most promise as a widely applicable means of air disinfection".
1
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage
or blindness.Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
page 2
INSTALLATION:
1. Choose a location for the Duo unit, with the following considerations: a. The Duo unit will reduce organic buildup on an HVAC cooling/ heating coil by illumination with UVC germicidal rays. Locate the Duo such that the maximum surface area of the coil is illuminated, while installing as close to the coil as possible without damage to the coil. CAUTION: Use care to avoid damage to the coil and any wiring or other components while installing the Duo 24V unit. b. The Duo 24V unit must be installed with its power cable within reach of the included 24V transformer, or the 24V power cable must be extended by using minimal 18 gauge wiring suitable for the installation, with maximum extension length of 20 feet. DO NOT connect to the HVAC system transformer, as this may overload the HVAC transformer and/or under-power the Duo 24V unit, which may cause damage and will void the factory warranty. The included transformer is i intended to be mounted on a 4x4 junction/conduit box or within an approved electrical enclosure. The provided 24V transformer shall be connected to 115 or 230 VAC power. c. The Duo 24V unit may be installed on either the supply or return plenum. d. The Duo 24V unit may be installed in up ow, down ow, or horizontal  ow ducts and plenums. e. The Duo 24V unit may be installed directly onto a sheet metal air duct or plenum, or onto  berglass ductboard when installed using the included Ductboard Adapter Plate (see Figure 1).
2. Install the Duo 24V unit: a. Hold or temporarily tape the included Ductboard Adapter Plate in the location chosen for installation, and using the plate as a template, mark the mounting surface using the outermost slots in the plate (see Figure 1). Alternatively, a 5-3/8” square may be marked on the mounting surface. b. Cut out the opening for the Duo unit in the mounting surface, making sure to cut slightly outside the marked lines if the Ductboard Adapter Plate was used as a template. c. If mounting the Duo unit on ductboard: attach the Ductboard Adapter Plate to the opening by folding the inner  aps of the plate into the opening and fully back against the inside of the opening in the ductboard, either from the sides or from top and bottom of the plate. Finish the Plate Adapter installation by sealing around the edges of the plate to the ductboard, using mastic foil tape or other material suitable for sealing duct joints. d. If the direction of air ow in the duct is downward, the white plastic ballast base that is attached to the Duo unit may
Figure 1
optionally be rotated 180 degrees from the position shown, so the ballast label will not be upside down. If desired, remove the four screws attaching the base to the Duo unit and re-install the base to the unit. Note: The white plastic base has a round sight glass hole for observing the lamp inside the duct (the sight glass may be seen above the center hole in the mounting base in Figure 2). There is a pair of holes in the Duo mounting  ange that allow the sight glass in the base to align with, in either position.glass may be seen above the center hole in the mounting base in Figure 2). There is a pair of holes in the Duo mounting  ange that allow the sight glass in the base to align with it, in either position.
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage
or blindness.Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
page 3
e. Insert the Duo unit into the duct opening and attach it to the duct (or Ductboard Adapter Plate) with the four included sheet metal screws. The wider end of the V-shape of the Duo unit should face into the oncoming airstream. Note: The white plastic base has a round sight glass hole for observing the lamp inside the duct (the sight glass may be seen above the center hole in the mounting base in Figure 2). In Figure 2, the unit is installed properly for a downward air  ow direction (note that the round sight glass hole will be upstream of the ballast when properly installed). f. Insert the UVC lamp pins into the ballast socket (see Figure 3). Note: the lamp has one long pin that must be aligned with the recessed terminal in the ballast socket. D o NOT directly touch the bulb lamp glass section with bare hands. Wear oil-free, cotton type gloves when han dling germicidal glass bulb.
Figure 2
Figure 3
g. Carefully insert the lamp through the center of the white plastic mounting base, align the ballast with the power cord pointing 90 degrees to the right of the round sight glass, and
engage the ballast onto the base by rotating the ballast ¼ turn to the right (see  gures 4 and 5). Note: the safety switch actuating  nger that projects from the mounting base must engage into the slot in the inside of the ballast. The slot is visible above the ballast socket in Figure 3.
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage
or blindness.Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
Figure 4
Figure 5
page 4
3. Ensure that power has been disconnected to the circuit that will provide power to the 24V
transformer, and install the transformer as directed in the installation instructions included with the transformer.
WARNING: MAKE SURE POWER IS DISCONNECTED TO THE CIRCUIT TO BE USED TO PROVIDE POWER
TO THE DUO 24V UNIT!
4. Connect the ballast power cord to the 24V transformer terminals, using the included crimp-on fork terminals.
5. Restore power to the circuit providing power to the 24V transformer.
6. Look through the round sight glass hole in the mounting base to verify that the UV-C lamp is lit. The lamp should have a blue glow along its length. If the lamp is not lit, carefully rotate the ballast ¼ turn to the left, partially remove it from the base, and re-install with the safety switch  nger engaging with the slot in the ballast as directed in Step 2f.
MAINTENANCE
WARNING: Disconnect power to the transformer before commencing inspection and cleaning.
NOTE: Wear disposable, non-absorbent protective gloves prior to inspection procedure in case of accidental breakage of glass.
1. We recommend inspecting and cleaning the lamp at least every 6 months. Frequency depends upon the environment. Such as: the type of air  lter, duration of use and replacement cycle.
2. To maintain maximum output intensity, replace the UV-Aire lamp annually. The lamp should operate continuously for maximum lamp life and light e ectiveness.
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage
or blindness.Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
page 5
REPLACEMENT PROCEDURE WARNING: Disconnect power to the transfomer before starting replacement procedure. NOTE: Wear disposable, non-absorbent protective gloves prior to replacement procedure in case of accidental breakage of glass.
1. Rotate the UV-Aire ballast assembly counter-clockwise until it stops. (See Figure 6)
2. Remove the ballast assembly and lamp from the mounting base. (See Figure 7)
3. Remove the lamp from the lamp socket.
4. Install the replacement lamp into lamp socket. Do not handle the lamp with bare hands. Oils on the hands tend to reduce lamp intensity.
5. Wipe o the glass with the supplied alcohol wipe.
6. Position the ballast assembly power cord 90° to the viewport hole on the mounting base. (See Figure 6)
7. Slide the lamp through the hole in the mounting base.
8. Press the ballast against the mounting base. Rotate the ballast assembly clockwise until it stops and is locked in place. (See Figure 8)
9. After assembly is  rmly in place, reconnect power to transformer. Check lamp operation by looking through the viewport hole. A blue glow should be seen in the duct.
10. After replacing the lamp, make sure to install the Lamp Replacement Label. Print the date on the label and apply to the side of ballast assembly.
Figure 6 (Removal)
Figure 7
NOTE: If blue light leaks through any portion of plenum and/or around mounting plate, unplug power supply cord immediately and seal a ected areas and/or rotate ballast and repeat step #8.
Figure 8 (Installed)
11. UV lamps contain a small amount of mercury, like a typical  uorescent lamp. Check with your local waste management authority for local disposal or recyclingrequirements. According to the EPA's Universal Waste Rule, these types of lamps may be disposed of into household waste.
WARNING: Never touch broken lamp or internal contents of lamp. The lamp contains mercury.
NOTE: In case of accidental exposure to internal contents of lamp, wash hands and any other a ected skin area with mild detergent. Remove a ected clothing immediately. If skin surface is pierced, seek medical attention immediately.
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage
or blindness.Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
page 6
TROUBLESHOOTING GUIDE
1. Do not wire the unit into the appliance 24 volt fan or thermostat circuit. This will cause premature ballast or lamp failure and void the warranty. For proper operation, the unit requires 24VAC at all times.
2. Check to make sure 24VAC power is available at the transformer.
3. If lamp does not light up, pull back metal washer on mounting base. If lamp comes on, the base needs tightening to ensure that the safety switch is fully engaged.
4. If lamp does not light up, remove the ballast from the base and re-install it onto the base, ensuring that the  nger projecting from the base engages into the safety switch slot in the ballast. Repeat step 3.
5. If lamp does not light up after performing Steps 3 and 4, replace lamp.
6. If unit still does not light up after replacing lamp, replace unit.
REPLACEMENT PARTS LIST
LAMP Replacement Part Number
46649301 11” Lamp Assy Duo
46649302 14” Lamp Assy Duo
46511200 16” Lamp Assy
For replacement parts, contact Field Controls at:
Phone: 252-522-3031 • Fax: 252-522-0214
Email: sales@ eldcontrols.com
CLEAN-UP OF BROKEN LAMPS (see warnings on page two of this manual)
UV lamps contain a small amount of mercury, like a typical  uorescent lamp. DO NOT touch any of the mercury with your bare hands.
1. While wearing disposable, non-absorbent protective gloves, carefully pick up the large pieces of glass with your hands.
2. Vacuum the entire area with a standard household vacuum cleaner ensuring the removal of all lamp material.
3. Dispose of the pieces of glass, the vacuum cleaner bag, and the disposable gloves in a sealed garbage bag.
4. Check with your local waste management authority for local disposal or recycling requirements. According to the EPA's Universal Waste Rule, these types of lamps may be disposed of into household waste.
5. Wash hands, and remove and wash clothes for added safety measures.
1
Richard Riley, M.D. “Airborne Infection: The American Journal of Medicine, September 1974, Vol. 57 - 5/16/01
2
The health aspects associated with the use of these products and their ability to aid in disinfecting of environmental air have not been
investigated by UL.
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage
or blindness.Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.
page 7
Warranty
For warranty information about this or any Field Controls product, visit:
www. eldcontrols.com/warranty
The health aspects associated with the use of these products and their ability to aid in disinfecting of environmental air have not been investigated by UL.
© Field Controls, LLC P/N 46648100 06/15
Phone: 252.522.3031 • Fax: 252.522.0214
www.fieldcontrols.com