The EvenAir wireless, remote control thermostat controls whole house fan or economizer operation for
free cooling. The TSRC can be wall mounted using the subbase supplied or on a table top using the
table top adapter provided. The TSRC can turn Econo Cooling On or Off and set the temperature for
cooling. The TSRC requires the ER1, Electronic Receiver Module, to be installed in the wiring hub.
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.
This device MUST be installed by a qualified agency in accordance with the manufacturer’s installation instructions.The definition of a
qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged in, and
is responsible for, the installation and operation of HVAC applicances, who is experienced in such work, familiar with all the precautions
required, and has complied with all the requirements of the authority having jurisdiction.
Please retain these instructions after installation.
AMJ Type Dampers (sold separately)
1 TS51 or 2 TS52 Wired Sensors (sold separately)
For Wireless Temperature Sensors
1 or 2 TSER Wireless Sensors (sold separately)
P/N 780101745 3/18 Rev Awww.fieldcontrols.com
Page 2
Thank you for purchasing the EvenAir System from Field Controls. The EvenAir products are compatible
with any HVAC system having accessible 24VAC terminals.
FEATURES
OPERATING MODES
Turns ECool On or Off.
POWER
Operates on two AA batteries.
TEMPERATURE CONTROL
ECool Temperature can be adjusted.
SLEEPING AREA TEMPERATURE SENSOR
The TSRC is factory set to address #2 and can be used as a
second sleeping area temperature sensor when used with the
TSER temperature sensor.
WIRING
No wiring is required.
Installation
Can be installed on any interior wall using the subbase
provided or set on a table top using the table top adapter
provided.
WIRELESS THERMOSTAT OVERVIEW
Press the touchscreen with your fingertip only, using a firm touch. Do not use a sharp object such as a pen or pencil.
!
The touchscreen is a resistive touch and responds differently than touch screens found in smart phones/devices.
Outdoor Temperature Display.
Touch here to set time of day.
Touch Menu key to
display and set options.
Outdoors
Link
ed
Menu
Cool
Set To
PM
R
Indoors
Econo
Cooling
ON
o
F
Touch Up or Down key to
adjust ECooling setpoint.
Touch Econo Cooling key to turn
ECooling On or Off.
page 2 of 8
P/N 780101745 3/18 Rev A
Page 3
HOMEOWNER SECTION
HOMEOWNER
This manual is separated into two different sections: one for the Homeowner and one for the System Installer.
The Homeowner section contains information on features and operation of the thermostat along with
optional user settings available to the homeowner.
THERMOSTAT OPERATION AND USER SETTINGS
Features
EvenAir Remote Control
1
Set Time and Day
2
Turn ECool On or Off
Change ECool Setpoint Temperature.
3
FEATURES
AUTOMATICALLY UPDATES COOLING SETPOINT
When the system is in Cool or ECool and the setpoint temperature is adjusted on the TSRC remote control, the new
setpoint is automatically updated on the EvenAir thermostat. Similarly, when the setpoint temperature is adjusted on the
EvenAir thermostat, the setpoint is automatically updated on the TSRC remote control.
User Options
1
Calibrate indoor temperature.
2
Clean the touch screen
3
Change the Home Number
Changing Batteries
CONTROL WHOLE HOUSE FAN OR ECONOMIZER USING 1-12 HOUR BUILT-IN TIMER
If control of a whole house fan or economizer was set to Timer Control during installation, turning ECool ON starts the
timer in the thermostat and operates the whole house fan or economizer for the time set by the user in the thermostat
(see Homeowner section in T32 or T32WF Thermostat Manual)
CONTROL WHOLE HOUSE FAN OR ECONOMIZER USING TEMPERATURE CONTROL
If control of a whole house fan or economizer was set to Temperature Control during installation, the whole house fan
or economizer will be activated if ECool is ON, the space temperature is above the setpoint temperature, and the
outdoor air temperature is cool enough to provide cooling. The whole house fan or economizer will automatically turn
off to save energy if the room temperature drops below the setpoint temperature.
If your whole house fan or economizer installation requires windows to be opened during operation,
!
be sure the windows are open before selecting the ECool mode on the TSRC remote control or
thermostat.
P/N 780101745 3/18 Rev Apage 3 of 8
Page 4
HOMEOWNER SECTION
THERMOSTAT OPERATION
1
Set Time
Touch here to change the time.
Outdoors
Indoors
2
Turn ECool On or Off
o
F
the area to the left of the key to turn
Touch the ECONO COOLING key or
Outdoors
Indoors
o
F
ECool ON or OFF. Turning ECool OFF,
turns the HVAC system to OFF.
Menu
Next
Menu Next
AM
AM
Enter
Enter
Cool
Link
ed
Set To
PM
Econo
Cooling
Menu
OFF
Touch the UP or DOWN key to set the hour
and AM or PM.
Touch NEXT.
Touch the UP or DOWN key to set the
minute.
Touch ENTER to save the time and return
to normal operation.
Econo Cooling (ECooling) is
Cool
controlled by either temperature or a
1 to 12hour timer in the EvenAir
thermostat and is set up by your
installer during installation.
Outdoors
Indoors
Cool
o
F
Link
Menu
ed
Set To
PM
Econo
Cooling
OFF
Solid ON indicates ECool mode
Link
ed
Set To
PM
Econo
Cooling
Menu
CONTROL BY TIMER
ECooling will start when ECool is turned ON and will remain
on until the timer expires or when ECool is turned OFF, which
turns the HVAC system OFF.
CONTROL BY TEMPERATURE
ECooling will start when ECool is ON, the space temperature is
above the setpoint temperature, and the outdoor air
temperature is cool enough to provide cooling. ECool will
automatically turn off if the room temperature drops below the
setpoint temperature.
is ON.
Blinking ON indicates an active
ECooling call.
ON
3
Change ECool Setpoint Temperature
Touch the UP or DOWN key to
change the ECooling Setpoint.
Outdoors
Link
ed
Menu
Cool
Set To
PM
Indoors
Econo
Cooling
OFF
o
When the system is in Cool or ECool and the setpoint
temperature is adjusted on the TSRC remote control, the new
setpoint is automatically updated on the EvenAir thermostat.
Similarly, when the setpoint temperature is adjusted on the
EvenAir thermostat, the setpoint is automatically updated on the
TSRC remote control.
P/N 780101745 3/18 Rev Apage 4 of 8
F
Page 5
HOMEOWNER SECTION
MENU OPTIONS
The MENU key is used by the homeowner or installer to access the following options:
Option
Description
01
Calibrating the Indoor Temperature Sensor
02
Clean the Touch Screen
03
Change the Home Number
i
Used By
Installer/User
Installer/User
Installer/User
The Home Number only needs to be changed if two installations are within 300 feet of one another. The Home Number
selected in the remote control must be the same as the Home Number selected in the EvenAir T32 Thermostat.
01
Calibrate Indoor Temperature
The indoor temperature is factory set to +/- 1F. If you feel the
thermostat temperature is too high or too low, use this option
to change the temperature (calibrate).
Outdoors
Link
ed
Menu
Touch the MENU key to
display Option 01.
Cool
Set To
PM
Indoors
Econo
Cooling
OFF
o
F
Option
Menu
Enter
Touch the UP or DOWN key to
change the temperature.
Touch ENTER to save the new
temperature or touch the MENU
key to go to the next option.
02
Clean the Touch Screen
This option disables the touch screen for 10 seconds to enable
the user to clean the touch screen by wiping down with a soft,
damp cloth.
Outdoors
Indoors
o
F
Range
+/-5
OFF or 10 seconds
1 to 8
03
Change the Home Number
DefaultAs Installed
NA
OFF
NA
NA
1
The Home Number is used by the ER1 receiving module when
communicating with wireless devices. The Home Number only
needs to be changed if two installations are within 300 feet of
one another.
Outdoors
Linked
Menu
Touch the MENU key
until Option 03 is displayed.
Cool
Set To
PM
Indoors
Econo
Cooling
OFF
o
F
Option
Menu
Enter
Touch the UP or DOWN key to
set a new Home Number, then
press ENTER.
i
The Home Number only needs to be changed if two
installations are within 300 feet of one another. The Home
Number selected in the remote control must be the same as
the Home Number selected in the EvenAir T32 Thermostat.
Change Batteries
Install 2 AA batteries.
Cool
Linked
Menu
Set To
PM
Econo
Cooling
OFF
Touch the MENU key
until Option 02 is
displayed, indicated
by CL. To exit this
Option
Menu
Enter
Press the UP key then
press ENTER to turn
ON the touch screen
cleaning cycle
option, press ENTER.
The touch screen is
disabled for 10
seconds.
P/N 780101745 3/18 Rev Apage 5 of 8
Page 6
INSTALLER SECTION
This manual is separated into two different sections: one for the Homeowner and one for the System Installer.
The Installer section contains setup and installation information of the remote control with optional user
settings available for the homeowner.
INSTALLATION
i
Homes with plaster walls with steel lathe may
experience wireless communication interference
when using wireless remote controls.
!
CAUTIONS
Read and follow all instructions carefully.
Read entire manual before installing EvenAir products.
Use cautions when mounting components to surfaces
that may have concealed wiring beneath the surface.
i
ATTENTION INSTALLER
Install and wire components to the wiring hub. (See
1)
H32 Wiring Hub manual for wiring detail)
2)
Install the ER1 electronic receiver module in the wiring
hub. The remote control is factory set to sensor #2.
Set the home number as necessary.
(see H32 Wiring Hub manual).
3)
After testing wiring hub and components installation,
place the remote control on the subbase or attach table
top adapter.
4)
Install batteries in remote control and set time (see
Installing Batteries and Set Time section).
INSTALL TSRC REMOTE CONTROL
The TSRC can be installed on an interior wall using the subbase
provided or can be set on a table top using the table top
adapter provided.
WALL MOUNTING
Attach the subbase to a wall
using the screws and anchors
provided. The TSRC snaps onto
the subbase. No wiring is
required.
5)
Linked should be displayed. Verify the wireless
communication by observing that the outdoor
temperature is displayed correctly.
INSTALL BATTERIES
Install 2 AA batteries.
TABLE TOP USE
Snap the tabletop adapter onto
the TSRC and place on table top.
P/N 780101745 3/18 Rev Apage 6 of 8
Page 7
MAINTENANCE AND TROUBLESHOOTING
REMOTE CONTROL OPERATION
Problem - Snr 02 is displayed on thermostat.
Replace the batteries.
Be sure the TSRC is set to the same Home number as the
T32 thermostat.
WARNING! When using a whole house fan or economizer requiring windows be opened, be sure the
windows are open before selecting ECool mode.
COMFORT CONCERNS
Problem - The room temperature on the remote control seems
too high or too low.
The remote control is factory calibrated within 1 degree.
However, if a homeowner finds the temperature “feels”
too high or too low, the remote control can be calibrated to
what the homeowner feels is the correct temperature using
the Menu key to select the Calibration Option.
Programmable, communicating thermostat w/ airflow control, for all equipment.
Programmable, communicating thermostat w/ airflow control for all equipment.
WiFi enabled.
Wiring Hub for gas/electric, conventional or dual fuel heat pump equipment with 3 Heat/2 Cool
Wired temperature sensor for the sleep area. Single sensor installation.
Wired temperature sensor for the sleep area. Dual sensor installation.
Wireless temperature sensor for the sleep area. Single or Dual sensor installation. Requires ER1.
Electronic receiver module. Required when using wireless sensors.
Outdoor temperature sensor. Required for dual fuel heat pumps.
Wireless remote control/temperature sensor. Requires ER1.
Replacement modulating actuator control, plug and play connectors.
Replacement 25 ft. RJ cable.
Additional 25 ft. RJ cable and connector.
Replacement idler shaft for AMT and AMJ actuators.
Replacement drive shaft for AMT and AMJ actuators.
EvenAir Round Balance Damper, Plug and Play. Sizes - 4” - 20” diameter.
EvenAir Rectangular Balance Damper, Plug and Play. Sizes - 8”, 10” and 12” Heights, up to 24” Length.
Relay, 24VAC Control, 250VAC Line, SPDT 90-370
P/N 780101745 3/18 Rev Apage 7 of 8
Page 8
This manual may be downloaded and printed from the Field Controls website (www.fieldcontrols.com)
WARRANTY
For warranty information about this or any Field Controls product, visit:
www.fieldcontrols.com
Field Controls Technical Support
1.800.742.8368
fieldtec@fieldcontrols.com
Field Controls Customer Service
1.252.522.3031
sales@fieldcontrols.com
9154 Stellar Ct
Phone: 252.522.3031 Fax: 252.522.0214
Corona, CA 92883
c
Field Controls, LLC
www.fieldcontrols.com
2630 Airport Road
Kinston, NC 28504
P/N 780101745 3/18 Rev A
Loading...