The EvenAir WiFi thermostat controls heating, cooling and AIRFLOW to the sleeping and living
areas in a home and provides remote access to your HVAC system using a smart phone, tablet or
PC. The thermostat is installed in the downstairs living area, a temperature sensor is installed in the
upstairs bedroom area and two modulating dampers are installed to control the airflow to the
living and sleeping area.
The EvenAir thermostat monitors the temperature at the sensor and the temperature at the
thermostat every 2 minutes during heating and cooling calls. If the temperatures are different, the
EvenAir thermostat automatically adjusts the modulating dampers 2% so that more airflow is
directed to the space that needs it for a uniformly comfortable home.
COMPONENTS:
EvenAir T21WF Thermostat
EvenAir TS51 or TS52 Wired Temperature Sensor(s) (sold separately)
EvenAir AMT Type Motorized Damper, With Terminals (sold separately)
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.
This device MUST be installed by a qualified agency in accordance with the manufacturer’s installation instructions.The definition of
a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged in,
and is responsible for, the installation and operation of HVAC applicances, who is experienced in such work, familiar with all the
precautions required, and has complied with all the requirements of the authority having jurisdiction.
Please retain these instructions after installation.
Thank you for purchasing the EvenAir System from Field Controls. The EvenAir products are compatible
with any HVAC system having accessible 24VAC terminals.
FEATURES
SYSTEM MODES
Off, Heat, Cool, Auto
FAN MODES
Auto or Continuous
THERMOSTAT MODES
Hold, Schedule or Vacant
PROGRAMS PER DAY
Morning, Daytime, Evening and Night
PROGRAM FORMAT
Weekdays and weekend – 5/2
TEMPERATURE OVERRIDE
Temperature is held for 3 hours when adjusted in Schedule
mode.
AIRFLOW OVERRIDE
The airflow to the living area or sleeping area can be adjusted.
After 3 hours, the thermostat returns to automatic airflow
control.
AIRFLOW CONTROL
Airflow control can be turned off and the thermostat will operate
as a typical thermostat.
AIRFLOW LIMITS
Maximum airflow limits can be set for heating and cooling
modes during installation.
NIGHTTIME OPERATION
At night, the EvenAir thermostat uses the temperature sensor in
the sleeping area to control heating and cooling calls and
directs more airflow to the sleeping area.
COMPATIBLE EQUIPMENT
Gas/electric equipment with 2-stage heating and 1-stage
cooling or 1-stage heating and 2-stage cooling and heat
pumps with 2-stage heating and 2-stage cooling.
TEMPERATURE SENSOR
One TS51 sensor or two TS52 temperature sensors can be used
in the sleeping area.
MODULATING DAMPERS
Round or rectangular dampers using the AMT actuator and up
to 1 inch static pressure.
WiFI
Connects to the home WiFi network to provide remote access
via the internet using smart phone, tablet or PC.
POWER
Operates on 24VAC from the HVAC equipment using the R and
C wires.
THERMOSTAT OVERVIEW
Press the touchscreen with your fingertip only, using a firm touch. Do not use a sharp object such as a pen or pencil.
!
The touchscreen is a resistive touch and responds differently than touchscreens found in smart phones/devices.
R
Displays the Thermostat Mode
HOLD, SCHEDULE or VACANT
Displays the sleeping area airflow
Displays WiFi status
Displays the living area airflow
Displays the time, day and
schedule. MORNING, DAYTIME,
EVENING or NIGHT
MENU Key
Displays User options.
MODE Key
Selects Thermostat Mode
HOLD, SCHEDULE or VACANT
WiFi
Sleeping
Airflow %
Living
Day
Tu
AM
Schedule
Cool
Set To
Living
COOL
SYSTEM
AUTO
FANMENUMODE
Displays the heating or
cooling temperature
UP/DOWN Keys
Displays the living area or
sleeping area temperature.
SYSTEM MODE Key
OFF, HEAT, COOL or AUTO
FAN MODE Key
AUTO or ON
ENTER Key
Used to save options and
return to thermostat operation
NEXT Key
Used to advance through
options
page 2 of 16P/N 780101703 3/18 Rev A
HOMEOWNER SECTION
HOMEOWNER
This manual is separated into two different sections: one for the Homeowner and one for the System Installer.
The Homeowner section contains information on features and operation of the thermostat along with
optional user settings available to the homeowner.
THERMOSTAT OPERATION AND USER SETTINGS
Features
EvenAir Thermostat Operation
1
Set Time and Day
2
Set System Mode
3
Set Fan Mode
4
Set Thermostat Mode
5
Changing Setpoint Temperature
Temperature Override
6
Displaying Upstairs Temperature
7
Overriding Automatic Airflow
8
9
Terminating Automatic Airflow
FEATURES
User Options
1
Set Schedule
2
Turn Automatic Airflow Control On/Off
3
Turn Nighttime Airflow Control On/Off
4
Set Nighttime Airflow in Heating
5
Set Nighttime Airflow in Cooling
Clean the Touchscreen
6
Turn Thermostat WiFi On
7
Start Linking WiFi Thermostat
8
Install Batteries
DISPLAYING THE LIVING AND BEDROOM AREA TEMPERATURE
The living area temperature is normally displayed. The bedroom area temperature can be displayed by touching
Living on the touchscreen. The temperature will change to the bedroom space temperature, indicated by Sleeping.
Touch Sleeping to return to displaying the Living area temperature.
NIGHTTIME AIRFLOW CONTROL
The Nighttime Airflow Control option is an energy saving feature where the thermostat uses the temperature sensor
in the bedroom area to control heating and cooling calls and directs more airflow to the bedroom at night
and less airflow to the unoccupied living . Nighttime Airflow Control begins at 10:00pm but can be changed
by accessing the schedule in the User Options. The airflow to the bedroom space defaults to 130% but can be
adjusted for both heating and cooling in the User Options. Nighttime Airflow Control is defaulted to On but can be
turned Off in the User Options. The homeowner should consider turning this option off if bedrooms are located on
the same floor as the living area and using the same airflow trunk as the living area.
AUTOMATIC OR MANUAL AIRFLOW CONTROL
Automatic Airflow Control is the thermostat default and is typically used by homeowners to maintain uniform
comfort throughout the home. However, homeowners with unusual work schedules, home offices, etc. may want to
use the manual airflow control feature. This features allows the homeowner to change the airflow level as desired
and hold that level indefinitely. This feature needs to be enabled using Installer Option 18. The homeowner then
needs to turn automatic airflow control off using the User Options. The Nighttime Airflow Control option is still
enabled but can be turned off, if desired, using the User Options.
AIRFLOW OVERRIDE
On occasion, homeowners may want to direct more airflow to an area. For example, during a party, more airflow
may be desired in the living area. The homeowner sets the airflow level to the area and the thermostat will hold
the airflow for 3 hours. After 3 hours, the thermostat returns to automatic airflow control.
area
area
AIRFLOW CONTROL TURNED OFF
In some installations, the EvenAir thermostat has been installed to control the system only. The thermostat operates
just like any other thermostat. The airflow control options are disabled and airflow is no longer displayed on the
thermostat.
WiFi REMOTE ACCESS
The EvenAir WiFi thermostat connects to the home’s WiFi network and provides remote access, via the internet, to your
home’s heating and cooling system from anywhere using a smart phone, tablet or PC.
page 3 of 16P/N 780101703 3/18 Rev A
HOMEOWNER SECTION
THERMOSTAT OPERATION
1
Set Time and Day
Touch here to change the time and day of the
week.
CHANGE THE HOUR
AM
NEXT
CHANGE THE MINUTE
AM
NEXT
CHANGE THE DAY OF THE WEEK
We
AM
i
Depending on the mode, setting the time
may reset the setpoint temperature to the
factory default heating or cooling setpoint.
Set System Mode
2
Touch the SYSTEM key to display the SYSTEM
MODES: OFF, HEAT, COOL or AUTO. In AUTO
or OFF, the setpoint for the last system call is
displayed.
Sleeping
Airflow %
Living
Day
Tu
MENUMODE
Sleeping
Airflow %
Living
Day
Tu
MENUMODE
Sleeping
Airflow %
Living
Day
Tu
MENUMODE
Sleeping
Airflow %
Living
Day
Tu
MENUMODEFAN
Schedule
AM
Schedule
AM
Schedule
AM
Schedule
AM
ENTER
ENTER
ENTER
Heat
Set To
Heat
Set To
Cool
Set To
Heat
Set To
Sleeping
Airflow %
Living
Day
Tu
AM
Touch the
UP/DOWN keys to
change the HOUR.
Touch NEXT.
Touch the
UP/DOWN keys to
change the MINUTE.
Touch NEXT.
Touch the
UP/DOWN keys to
change the DAY OF
THE WEEK.
Touch ENTER.
OFF
Heating and cooling
systems are off.
OFF
Living
SYSTEM
AUTO
FAN
HEAT
Only heating calls are
Living
setpoint is displayed.
SYSTEM
“HEAT” will blink in
AUTO
an active heating call.
FAN
enabled and heating
HEAT
COOL
Only cooling calls are
Living
enabled and cooling
COOL
setpoint is displayed.
SYSTEM
“COOL” will blink in
AUTO
an active cooling call.
FAN
AUTO
Heating or Cooling
Living
calls are enabled.
“HEAT” will blink in
AUTO
SYSTEM
an active heating call
AUTO
or “COOL” will blink
in an active cooling
call.
Schedule
Cool
Set To
Living
COOL
SYSTEM
AUTO
FANMENUMODE
3
Set Fan Mode
Touch the key to change the FAN MODES -
FAN
AUTO or ON.
Sleeping
Airflow %
Living
Day
Tu
AM
MENUMODE
Sleeping
Airflow %
Living
Day
Tu
AM
MENUMODE
4
Set Thermostat Mode
Touch the key to display the THERMOSTAT
MODE
Schedule
Schedule
Cool
Set To
Living
Cool
Set To
Living
AUTO
Fan is activated only
during heating or
COOL
cooling calls. This is
SYSTEM
the most commonly
AUTO
used setting.
FAN
ON
Fan is continuously
on.
COOL
SYSTEM
ON
FAN
MODES: HOLD, VACANT and SCHEDULE.
Sleeping
Airflow %
Living
Day
Tu
AM
MODE
Sleeping
Airflow %
Living
Day
Tu
AM
MODE
Sleeping
Airflow %
Living
Day
Tu
AM
MODE
Changing the Setpoint Temperature
5
Cool
Set To
Hold
Cool
Set To
Vacant
Cool
Set To
Schedule
HOLD MODE
Setpoint temperatures
are set by the user.
Living
COOL
No schedule is used.
SYSTEM
AUTO
FANMENU
VACANT MODE
Setpoint temperatures
are kept at the vacant
Living
COOL
temperatures set by
SYSTEM
the installer.
AUTO
FANMENU
SCHEDULE MODE
Setpoint temperatures
are changed at
Living
COOL
scheduled times
SYSTEM
defined by the user.
AUTO
FANMENU
The UP/DOWN keys are used to change the
setpoint temperature.
Sleeping
Airflow %
Living
Day
Tu
AM
MENUMODE
Schedule
Cool
Set To
Living
Touch the UP key to
raise setpoint
temperature.
COOL
SYSTEM
Touch the DOWN
AUTO
key to lower setpoint
FAN
temperature.
An active heating call is indicated by HEAT
blinking. An active cooling call is indicated by
COOL blinking.
Sleeping
Airflow %
Living
Day
Tu
AM
MENUMODE
Schedule
Heat
Set To
Living
Touch here to display
and change the
opposing setpoint
COOL
temperature.
SYSTEM
AUTO
FAN
Touch the UP/DOWN keys to change the setpoint
temperature for the opposing system. The
thermostat will return to displaying the active
setpoint after about 30 seconds.
page 4 of 16P/N 780101703 3/18 Rev A
6
Temperature Override
To override the setpoint temperature:
Tu
Sleeping
Airflow %
Living
Day
Cool
Set To
Schedule
Living
AM
Touch the UP/DOWN
keys to adjust the
setpoint temperature.
COOL
After 3 hours, the
SYSTEM
AUTO
thermostat returns to
FANMENUMODE
normal thermostat
operation.
7
Displaying the Upstairs Temperature
The thermostat displays the temperature in the
downstairs living area and is indicated by Living.
The temperature in the upstairs sleeping area is
indicated by Sleeping. When the thermostat enters
Night Mode, the upstairs sleeping area temperature
will be displayed, indicated by Sleeping.
MENU
MENU
Sleeping
Airflow %
Living
Day
We
Sleeping
Airflow %
Living
Day
We
Cool
Set To
Schedule
AM
Cool
Set To
Schedule
Sleeping
AM
Press Living to display
the upstairs Sleeping
area temperature.
COOL
Living
SYSTEM
AUTO
FANMODE
The upstairs Sleeping
area temperature is
now displayed.
COOL
SYSTEM
Press Sleeping to
AUTO
FANMODE
display the Living
area temperature.
8
Overriding Automatic Airflow
Sleeping
Airflow %
Living
We
Sleeping
Airflow %
We
Cool
Set To
Hold
Eve
PM
MODE
Living
Eve
PM
Living
Hold
Touch the Airflow %
area to override
AUTOMATIC AIRFLOW
COOL
to the living area or
SYSTEM
the upstairs sleeping
AUTO
FANMENU
area.
Touch the UP key to
increase the airflow to
Living
the sleeping area or
COOL
touch the DOWN key
SYSTEM
to increase airflow to
AUTO
FANMENUMODE
the living area.
Airflow % will blink to indicate airflow override.
After 3 hours, the thermostat returns to automatic
operation. The override range is defined by the
installer during set up.
9
Terminating Airflow Override
Sleeping
Airflow %
Living
We
Sleeping
Airflow %
Living
We
Cool
Set To
Hold
Eve
PM
MODE
Eve
PM
MODE
Living
Hold
Living
To terminate Airflow
Override, touch the
AIRFLOW% area.
COOL
SYSTEM
AUTO
FANMENU
Then touch the
MODE key.
COOL
SYSTEM
AUTO
FANMENU
The thermostat returns to automatic airflow
control. The AIRFLOW % returns to the airflow
prior to the override.
HOMEOWNER SECTION
USER OPTIONS
Factory Set Schedule
The thermostat comes pre-set with the
following energy-saving schedule for
weekdays (Mon-Fri) and weekends (Sat-Sun).
Using these settings can reduce your heating
/cooling expenses.
Monday - Friday
Morn
Day
Even
Nite
Saturday & Sunday
Morn
Day
Even
Nite
1
Change Factory Set Schedule
Sleeping
MENU
Tu
Airflow %
Living
Day
Schedule
AM
SELECTING THE WEEKDAY OR
WEEKEND SCHEDULE
WeTuMo ThFr
MENUNEXT ENTER
Schedule
SETTING THE MORNING
SCHEDULE START TIME.
Morn
WeTuMo
ThFr
MENUNEXT ENTER
Schedule
AM
SETTING THE MORNING
HEATING TEMPERATURE.
Morn
WeTuMo
ThFr
MENUNEXT ENTER
Schedule
AM
SETTING THE MORNING
COOLING TEMPERATURE.
Morn
WeTuMo
ThFr
MENU
Schedule
AM
NEXT ENTER
Continue setting the start times, heating setpoints,
cooling setpoints for the Day, Evening and Night
schedules.
Touch ENTER to save the schedule.
TimeHeat Cool
6:00 AM
8:00 AM
6:00 PM
10:00 PM
TimeHeat Cool
6:00 AM
8:00 AM
6:00 PM
10:00 PM
Touch the
Cool
Set To
Living
key to display
SCHEDULE. If no
COOL
key is touched, the
SYSTEM
thermostat returns to
AUTO
normal operation
FANMODE
after about 30
seconds.
Touch the UP key to
select the weekday
schedule
(MoTuWeThFr) or
touch the DOWN
key to select the
weekend schedule
(SaSu). Touch NEXT.
Touch the
UP/DOWN keys to
change the Morning
Start Time. Touch
NEXT.
Heat
Set To
Touch the
UP/DOWN keys to
change the Morning
Heating Setpoint.
Touch NEXT.
Touch the
Cool
Set To
UP/DOWN keys to
change Morning
Cooling Setpoint.
Touch NEXT.
70
62
70
62
70
62
70
62
MENU
75
83
75
78
75
83
75
78
2
Automatic Airflow Control On or Off
i
This option is only displayed if User Airflow
Control has been turned On by the installer in
the Installer Options.
i
Homeowners with an unusual schedule, home
office, etc. may want to use this option.
i
With Automatic Airflow Control Off, the
Nighttime Airflow option is still enabled. If
desired, the homeowner can turn the
Nighttime Airflow option off using User
Options.
Touch the MENU key until the following
thermostat screen is displayed.
Thermostat defaults
Airflow %
to Automatic Airflow
Control On and
automatically directs
more airflow to where
MENU
NEXT
ENTER
it’s needed.
To turn Automatic
Airflow %
Airflow Control OFF,
touch the DOWN
key. The user must
set the airflow when
NEXTMENUENTER
Touch the key to save and go to next
MENU
airflow control is off.
option or touch the ENTER key to save the options
and return to normal thermostat operation.
3
Nighttime Airflow Control On or Off
i
This option is not displayed if Nighttime
Airflow Control has been turned off by the
installer using the Installer Options.
i
If bedrooms are located downstairs, consider
turning the Nighttime Airflow Control OFF.
NIGHTTIME AIRFLOW CONTROL defaults to On
and is used to save energy. The thermostat uses
the temperature sensor in the sleeping area for
controlling heating and cooling calls. The airflow
is increased to 130% to the sleeping area and the
airflow is reduced to 70% to the unused living
area. The thermostat displays the sleeping area
temperature.
Upstairs
Airflow %
Night
Touch the MENU key
to display
NIGHTTIME
AIRFLOW indicated
by nAF On or Off.
MENUNEXT ENTER
Upstairs
Airflow %
Night
Touch the UP key to
turn the option ON.
Touch the DOWN
key to turn the
option OFF.
MENUNEXT ENTER
Touch the MENU key to save and go to next
option or touch the ENTER key to save the options.
page 5 of 16P/N 780101703 3/18 Rev A
3
Nighttime Airflow Control (cont.)
i
Default start time for Nighttime Airflow is
10:00pm but can be changed using User
Option 1 to change the Night Schedule Start
Time.
i
Default airflow level upstairs is 130%. If a
different airflow level is desired, use User
Option 4 to change the airflow level in heating
and User Option 5 to change the airflow level
in cooling.
4
Set the Nighttime Airflow in Heating
i
This option is not be displayed if Airflow
Control has been turned off.
This option is used to change the default
nighttime airflow in heating of 130% to a user
desired airflow level, not to exceed installer limits.
Sleeping
Airflow %
Night
MENUENTER
Touch the key to display NIGHTTIME,
MENU
Heat
NEXT
UPSTAIRS AIRFLOW IN HEATING indicated by
nAF Heat.
Use the UP/DOWN keys to adjust the airflow.
Touch the MENU key to save and go to next
option or touch the ENTER key to save the option.
Set the Nighttime Airflow in Cooling
5
i
This option is not displayed if Airflow Control
has been turned off.
This option is used to change the default
nighttime airflow in cooling of 130% to a user
desired airflow level, not to exceed installer limits.
Sleeping
Airflow %
Night
MENUENTER
Cool
NEXT
Touch the MENU key to display NIGHTTIME,
UPSTAIRS AIRFLOW IN COOLING indicated by
nAF Cool.
Use the UP/DOWN keys to adjust the airflow.
Touch the MENU key to save and go to next
option or touch the ENTER key to save the
options.
Loading...