Field controls CAS-1, CAS-2A, CAS-2B, CAS-2C, CAS-2W User Manual

...
Combustion AIR Systems (oil)
W
CAS-1 and CAS-2 (oil)
Direct Connect
The CAS-1 and CAS-2 Field Combustion Air Systems provide controlled amounts of outside air for proper combustion of oil heating appliances. These models were designed specifically for use with Aero, Beckett, Carlin, Riello, or Wayne burners.
HEN TO USE THE CAS SYSTEM:
Too tight construction
Provide source of fresh air for combustion
CAS-1 & CAS-2 connect directly to oil
burners
4” VRV
Vacuum Relief Valve
Furnace Boot™
With telescopic Feature
(Allows units to fit
any furnace cabinet)
Intake Air Hood
AirBoot®/
Furnace Boot™
Pipe
Diameter
4” 44’ 7’
Maximum
Linear
Feet
Feet/
Elbow
5” 60’ 9’
Field BigBoot™
6” 90’ 11’ 6” 30’ 11’ 7” 60’ 12’ 8” 100’ 14’
Model
CAS-1 Oil
CAS-2A
CAS-2B CAS-2C CAS-2W
CAS-2B-90E Oil
CAS-2BB Oil
CAS-2B375 Oil Beckett CF-375
CAS-2BC Oil
Fuel
Beckett AFII, Riello 40BF
Oil
Aero FAFC, HF-US, HF-AFC, (S)SV
Beckett AFG or AF,
Oil
Carlin EZ-1, CRD, FRD, Wayne MSR
Beckett AF & AFG warm air furnaces
Beckett SF, SMG,CF-500, CF­800
Carlin, 99-FRD,100­CRD,102-CRD
Burner
Appliance
Input
Up to 2
gph
Up to 2
gph
Up to 1.5
gph
Up to 4.5
gph
Up to 3.5
gph
Up to 4.5
gph
Field AirBoot® or Field BigBoot
Components
4” Intake Air Hood 4” Vacuum Relief Valve 4” Intake Air Hood 4” Vacuum Relief Valve
Field AirBoot®
4” Intake Air Hood 4” Vacuum Relief Valve FurnaceBoot™ 6” Intake Air Hood 6” Vacuum Relief Valve Field BigBoot™ 6” Intake Air Hood 6” Vacuum Relief Valve Field BigBoot™ 6” Intake Air Hood 6” Vacuum Relief Valve Field BigBoot™
CAS-3 (oil)
W
This model is designed to provide combustion air for appliances when direct connecto the burner is not possible. According to NFPA 54 and NFPA 31, an engineered system such as a CAS-3 may be used to overcome the lack of air in a confined space. The CAS-3 is designed for optimum safety and includes a proving device that won’t allow the burner to engage without the Fan-in-a-Can™ operating. Multiple units or additional controls are required for multiple appliance installations. The CAS-3 is equipped with a two speed control for enhanced versatility.
HOW THE CAS-3
When the thermostat calls for heat, the Fan­in-a-Can™ engages and begins drawing outside air into the structure. When air flow is established, the CAS allows the burner to activate. The Fan-in-a-Can™ diffuses the outside air into the room near the burner.
ORKS:
Model
Number
CAS-3 Oil
Fuel Application Components
Any oil heating
appliance
4” Intake Air Hood Fan-in-a-Can™ Assembly 6” to 4” Reducer Restrictor Plate
Intake Air Hood
Fan-in-a-Can™ Assembly
P/N 46457000 10/03