Combustion AIR Systems (oil) 
CAS-1 and CAS-2 (oil) 
Direct Connect 
The CAS-1 and CAS-2 Field Combustion Air Systems 
provide controlled amounts of outside air for proper 
combustion of oil heating appliances. These models were 
designed specifically for use with Aero, Beckett, Carlin, 
Riello, or Wayne burners. 
HEN TO USE THE CAS SYSTEM:
• Too tight construction 
• Provide source of fresh air for combustion
• CAS-1 & CAS-2 connect directly to oil 
burners 
4” VRV 
Vacuum 
Relief 
Valve 
Furnace Boot™ 
With telescopic 
Feature 
 (Allows units to fit 
any furnace cabinet)
  Intake Air Hood 
AirBoot®/ 
Furnace Boot™ 
Pipe 
Diameter 
4” 44’ 7’ 
Maximum 
Linear 
Feet 
Feet/ 
Elbow 
5” 60’ 9’ 
Field BigBoot™ 
6” 90’ 11’ 
6” 30’ 11’ 
7” 60’ 12’ 
8” 100’ 14’ 
Model 
CAS-1 Oil 
CAS-2A 
CAS-2B 
CAS-2C 
CAS-2W 
CAS-2B-90E Oil 
CAS-2BB Oil 
CAS-2B375 Oil Beckett CF-375 
CAS-2BC Oil 
Fuel 
Beckett AFII, Riello 
40BF 
Oil 
Aero FAFC, HF-US, 
HF-AFC, (S)SV 
Beckett AFG or AF, 
Oil 
Carlin EZ-1, CRD, 
FRD, Wayne MSR 
Beckett AF & AFG 
warm air furnaces 
Beckett SF, 
SMG,CF-500, CF800 
Carlin, 99-FRD,100CRD,102-CRD 
Burner 
Appliance 
Input 
Up to 2 
gph 
Up to 2 
gph 
Up to 1.5 
gph 
Up to 4.5 
gph 
Up to 3.5 
gph 
Up to 4.5 
gph 
Field AirBoot® 
or 
Field BigBoot™
Components 
4” Intake Air Hood 
4” Vacuum Relief Valve 
4” Intake Air Hood 
4” Vacuum Relief Valve 
Field AirBoot® 
4” Intake Air Hood 
4” Vacuum Relief Valve 
FurnaceBoot™ 
6” Intake Air Hood 
6” Vacuum Relief Valve 
Field BigBoot™ 
6” Intake Air Hood 
6” Vacuum Relief Valve 
Field BigBoot™ 
6” Intake Air Hood 
6” Vacuum Relief Valve 
Field BigBoot™ 
 

CAS-3 (oil) 
This model is designed to provide combustion air for 
appliances when direct connecto the burner is not 
possible. According to NFPA 54 and NFPA 31, an 
engineered system such as a CAS-3 may be used to 
overcome the lack of air in a confined space. The CAS-3 
is designed for optimum safety and includes a proving 
device that won’t allow the burner to engage without the 
Fan-in-a-Can™ operating. Multiple units or additional 
controls are required for multiple appliance installations.  
The CAS-3 is equipped with a two speed control for 
enhanced versatility. 
HOW THE CAS-3 
When the thermostat calls for heat, the Fanin-a-Can™ engages and begins drawing 
outside air into the structure. When air flow 
is established, the CAS allows the burner to 
activate. The Fan-in-a-Can™ diffuses the 
outside air into the room near the burner. 
ORKS:
Model 
Number 
CAS-3 Oil 
Fuel Application Components 
Any oil 
heating 
appliance 
4” Intake Air Hood 
Fan-in-a-Can™ Assembly 
6” to 4” Reducer 
Restrictor Plate 
Intake Air Hood 
Fan-in-a-Can™ 
Assembly 