1-UV-Aire power unit
4-Sheet metal mounting screws
1-Angled mounting bracket
1-Flat mounting bracket
1-Duct board mounting bracket
1-Ultra Violet lamp
1-Instruction Sheet
1-Wing nut
Caution Labels
Gasket
UV-C light inhibits the growth and reproduction of germs and bacteria that circulate through a
homes’ heating and air conditioning system. The treatment is a safe, silent, and proven way
to make your home a healthier place to live.
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION
LEAVE THE INSTALLATION INSTRUCTIONS WITH THE OWNER/OPERATOR OF THE DEVICE
AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE.
DO NOT INSTALL THIS UNIT IF ANY DAMAGE IS NOTICEABLE.
SAFETY CONSIDERATIONS
WARNING: Never expose eyes or skin to UVC light from any source.
• Looking directly at the UVC light may cause permanent eye damage or blindness.
• Never operate the UV-Aire™ Air Purifying System out of the plenum.
• Designed for a closed duct system. Do not mount near a supply or a return air opening
• All duct openings in direct line of site of the UV light must be sealed with aluminum duct tape or equivalent
sealing methods.
WARNING: UV light will break down plastic materials not rated for UV exposure:
(Examples: wire insulation, flex duct, drain pans and humidifiers)
• The unit must be mounted at least 30” from the above stated type of materials.
• If it is necessary to mount the unit in direct line of site of these types of materials, they must be shielded
with aluminum foil, aluminum foil tape, or sheet metal.
WARNING: DO NOT mount this unit outdoors.
• This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, etc.).
Page 2
I. INDICATION FOR USE
r
r
This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for
use in the mitigation, treatment, or prevention of any disease or condition.
II. GENERAL INFORMATION
There are different size units available, depending on the square footage of your home. See chart below for
determining your homes needs.
Model
Minimum
Duct
Width
Volts Amps
Hz
Watts
UV-12 9 120 0.5 60 30 190°
UV-18 14 120 0.5 60 30 190°
Max Air
Temp °F
Lamp Intensity at 1
meter
37 µW/cm
73 µW/cm
2
2
Recommended
Max Sq. Feet
1500
2000
WARNING: Before installing or servicing a humidifier, air filter, heat system, or this unit, etc., always turn all power
OFF and have unit unplugged. Electrical shock can cause personal injury or death. Never expose eyes or skin to
direct UVC light from any source.
WARNING: To prevent water damage or electric shock, do not mount unit under a humidifier.
WARNING: Designed for a closed duct system. Do not mount near a supply or a return air opening.
WARNING: This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, etc.). For
use on gas fired, oil fired, electric and split system heat pump forced air systems*. This product is NOT designed
to be mounted outside on gas fired or heat pump packaged units**.
*Split system heat pumps are systems where the air handler and the air conditioning compressor are separate units.
**Packaged units are systems where the air handler and the air conditioning compressor are built together and are installed outside of the building
III. INSTALLATION
1. Locate a suitable location for the unit downstream from the ‘A’ coil in the supply plenum or in the return plenum;
preferably downstream from the air filter. For optimum “cleaning” effect on the ‘A’ coil, mount the unit in the supply
plenum as close as possible to the ‘A’ coil. (See Figure 1)
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage o
blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with you
hands.
Figure 1
Page 2
Page 3
2. Determine the type of duct you have.
r
r
(For flex duct applications, refer to Figure 21 on page 8)
F YOU HAVE METAL DUCT:
I
a. Apply supplied wet and stick mounting template to air duct in
either a vertical or horizontal position as shown in Figure 2.
b. Drill 1/8” diameter mounting holes at positions indicated on
template.
c. Cut out the marked openings on template using a hole saw
or a pair of tin snips or jigsaw. (See Figure 2)
d. Remove paper template from duct.
I
F YOU HAVE DUCT BOARD:
a. Mount the supplied metal mounting plate onto the duct with
Figure 2
duct tape in either a vertical or horizontal position as shown
in Figure 2. (See Figure 3)
b. Bend tabs outward as shown in figure 4.
c. Using a knife or blade, cut out a rectangle opening in the duct using the mounting plate as a template. (See
Figure 5)
d. Remove the cut piece of duct. (See Figure 6)
e. Bend both tabs down and through duct at first bend point. (See Figures 7 & 8)
f. Bend both tabs at the second bend point up or down to pinch the duct material and grip the duct material.
(See Figures 9 & 10
g. Using a screwdriver or pointed object, locate mounting holes by poking holes through the duct tape. (See
Figure 11)
Figure 3
Figure 7
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage o
blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with you
hands.
Figure 4
Figure 8Figure 9
Page 3
Figure 5
Figure 6
Figure 10Figure 11
Page 4
3. Remove base unit and cover from box.
r
r
4. Apply supplied “Duct Seal Kit” according to instructions included in kit
(See Figure 12)
5. Determine whether to use flat or angled bracket. (Refer to UV-Aire
“Bulb Mounting Bracket Selection” in section IV for aid in this decision)
a. Flat Bracket Installation
i. Remove the two hex nuts and flat bracket from included bagged
hardware.
ii. Install the flat bracket and secure to the unit base with the hex
nuts provided. (See Figure 13)
Figure 12
Figure 13
b. Angled Bracket Installation
NOTE: For angled bracket mounting, refer to specifications outlined by
Diagrams A & B for mounting distances in the “Angled Lamp Mounting
Bracket Specifications” in section IV.
i. Remove the two hex nuts and angled bracket from included
bagged hardware.
ii. Install the angled bracket and secure to the unit base with the hex
nuts provided. (See Figure 14)
NOTE: Be sure to note location of lamp hole in bracket relative to
unit base.
6. Mount the unit base to the duct using the four mounting screws provided. (See Figure
15)
7. Remove tag and alcohol wipe from lamp. Wipe off lamp being sure not to touch lamp
with bare hands. The oils from your hands will reduce lamp output.
Figure 14
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage o
blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with you
hands.
Figure 15
Page 4
Page 5
r
r
8. Insert lamp through hole until lamp cannot be inserted any further. (See
Figure 16)
9. Swing the swivel bracket over end of lamp. Hand-tighten the wing nut
on stud. (See Figure 17) Be careful not to over tighten the wing nut. The
porcelain at the lamp base may crack when over tightened.
10. Plug ballast plug into end of lamp. (See Figure 18)
11. Snap cover onto the unit base. Close the cover and tighten cover screw. (See
Figure 19 & 20)
Figure 16
Figure 17
Figure 18
12. Plug the power cord into a standard electrical outlet.
NOTE: Seal the joints and seams of the plenum near the mounting
location to reduce any direct viewing of light. (See Figure 1)
13. Press the power switch to the ‘ON’ position. (Light on switch should be on indicating power.)
14. Look through view port in the box cover to be sure lamp is working. You should see a blue glow. (The view port
is covered with a plastic lens that blocks the UVC rays.)
15. If the lamp is not glowing, follow steps 8-14 again. If lamp still does not glow, contact technical support at 1-252522-3031 for further assistance.
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage o
blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with you
hands.
Figure 19
Figure 20
Page 5
Page 6
r
r
IV. BULB MOUNTING BRACKET SELECTION
TM
The UV-AIRE
units come with an angled mounting bracket and flat mounting bracket to position the bulb either
straight or at an angle. Choose one or the other bracket method best suited for your needs. Refer to the
configurations chart below when making your selection.
UV-Aire™ Configurations
Good Best
Standard 90°
Installation
(Flat Bracket)
(16” Duct)
A
NGLED LAMP MOUNTING BRACKET SPECIFICATIONS
Use the specifications below to determine allowable clearances for proper mounting of the UV-Aire™ unit on the duct.
Chart A
Patent Pending 45°
Installation
Single Lamp
(Angled Bracket)
(16” Duct)
Chart B
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage o
blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with you
hands.
LAMP OFFSET DIMENSIONS
Min Duct
Size
(inches)
Page 6
A B
Unit
UV-12 9x12 8-1/2 6-1/2
UV-18 14x18 13-1/2 10-5/16
Page 7
V. MAINTENANCE
r
r
1. Inspect and clean lamp at least every 6 months.
2. Replace your UV-Aire™ Air Purifying System lamp once a year to maintain the lamps maximum output intensity.
The lamp should operate continuously for maximum lamp life and light effectiveness.
VI. LAMP REPLACEMENT PROCEDURE
VERY IMPORTANT: Turn switch on unit to ‘OFF’ position and unplug unit from outlet.
1. Loosen the cover screw on the side of the unit and open cover.
2. Unplug ballast plug from end of lamp.
3. Loosen the wing nut on swivel bracket and rotate the bracket clockwise.
4. Slide lamp out carefully.
NOTE:When replacing the lamp, always wipe off lamp before installing.
5. Insert the lamp through the mounting hole and secure the lamp by rotating the swivel bracket counter-clockwise
into position and secure by tightening wing nut. Be careful not to over tighten the wing nut.
NOTE: UV lamps contain a small amount of mercury, like a typical fluorescent lamp. Check with your local waste
management authority for local disposal or recycling requirements. According to the EPA’s Universal Waste Rule,
these types of lamps may be disposed of into household waste.
6. Attach the ballast plug onto the end of the lamp.
7. After replacing lamp, make sure a new Lamp Replacement Label (supplied with lamp replacement) is applied to
the housing and dated with the date of installation.
VII. TROUBLESHOOTING GUIDE
1. If the lamp does not light up, replace the lamp.
2. If the lamp still does not light up after replacing the lamp, replace ballast.
VIII. REPLACEMENT PARTS LIST
MODEL
UV-12 46365401 46365508
UV-18 46365402 46365509
For replacement parts, contact your local heating service company. Any questions, please contact Field Controls at:
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage o
blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with you
hands.
Page 7
Page 8
IX. FLEX DUCT INSTALLATION
For installations on duct systems with a metallic main duct and flex duct branches, follow the instructions in figure 21
below.
Figure 21
WARRANTY INFORMATION
FIVE YEAR LIMITED WARRANTY (excluding lamps, which have a 90 day warranty, from day of installation)
The products of The Field Controls Co. are warranted to be free from defects in material and workmanship under normal use for five (5) years from date of
manufacture. In the event of malfunction or failure of this product, the purchaser shall properly package the entire unit and ship it PREPAID with return address to
the address listed below. At the time of request for warranty service, the purchaser must present proof of purchase documentation which includes the date of
purchase (for example, a receipt or sales slip). If the malfunction or failure is a result of defects covered by this warranty, Field will, at its option, repair the product
or replace it and return it to the purchaser.
This warranty is limited to the original retail purchaser and is not transferable. The warranty does not cover damage due to accidents, abuse, tampering or misuse,
nor does it cover damage resulting from service persons other than Field. Field’s liability under this warranty is expressly limited to the repair, replacement, or
refund of the invoice price of products which prove to be defective in material or workmanship within a period of ninety days from date of purchase. Field’s
obligation to repair or replace defective products or refund of invoice price constitutes agreed and liquidated damages for any breach of warranty by Field.
FIELD’S LIABILITY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF A DEFECTIVE PRODUCT WITH THE EXCEPTION OF
DAMAGES RESULTING FROM FIELD’S FAILURE TO COMPLY WITH FEDERAL OR STATE WARRANTY LAW. FIELD SHALL NOT BE LIABLE FOR ANY
INCIDENTAL OR CONSEQUENTIAL DAMAGES, WHETHER DIRECT OR INDIRECT.
THIS WARRANTY IS EXPRESSLY GRANTED IN LIEU OF ALL OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Some states may not allow the exclusion or limitation of incidental or consequential damages, or limitations on how long an implied warranty lasts, so the above
limitations or exclusions may not apply to you. This warranty gives you specific rights and you may also have other rights which vary from state to state.
In the event you have any questions concerning the use and care of your Field product or concerning service under this warranty or otherwise, please write: The
Field Controls, L.L.C. 2630 Airport Rd., Kinston, N.C. 28504.
The health aspects associated with the use of these products and their ability to aid in disinfecting of environmental air have not been investigated by UL.
Page 8
P/N 46360900 Rev N 09/04
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.