Field Controls 094021a0104p, 094021a0004p Owner's Manual

This symbol on the product means
US
the product is listed by Underwriters Laboratories, Inc.
Installation
C
U
R
L
Instructions & Owner's Manual
ELECTRONIC STEAM UNIT - POWER HUMIDIFIER MODELS S2000 AND S2020
FOR GAS OR OIL FORCED AIR FURNACES, HEAT PUMPS AND ELECTRIC FURNACES
The AutoFlo Residential Power Humidifier you have purchased has been designed to be simple to Install, Operate and Maintain. Read this manual before you install the Humidifier.
WATER INLET
WATER LEVEL PROBE
HEATER
TEMPERATURE PROBE
FIG. 1
Familiarizing yourself with the items listed in Figures 1 and 2 will assist you in installing and maintaining your Steam Power Humidifier.
WATER PAN
TANK BAFFLE
FOR DRAIN VALVE DETAILS SEE FIG. 8
WATER INLET
E
w
c
C
O
N
T
R
O
L
S
,
I
NC.
S
t
P
e
O
a
W
m
Mo
d
2
.
0
KW
S
ui
t
a
b l
e
3
8
5
H
i
g
h
s
e r
i a
l n
u
m
be
U
. S
. P
F
A
o
r
T
R
E
e
N
p
l
0
a
9
c
0
e
2
m
1
e
A
n 0 1
1 8
E
R
®
H
u
e
m
T
l
h e
S
i
r
d
m
2
i s
i
H
t
f
o
0
e
i
r
a
e
2
2
t e
r
4
r
0
W
0
a
f
o
V
t e
r
o
r
R
l
e
t
s
i
8
d
e
.
nt
3
w
ia
a
B
A
y
l
LO
U
m
3
s
3
e
W
ps
,
O
E
E
r
n
n
R
l
g
y
l
i
s
h
t
o
H
w
EAT
n
,
N
J
E
T
0
R
7
N
7
U
2
M
t
6
P
BE
a r
C
t s
R
C
F
a
5
U
l
l
I
7
(
L
8
5
0
8
L
®
0 )
0
4
L
1
4 6
8
U
­3
1
S
1
0
L
I S
T
DR
E
D
1
A
4
1
I
N
V
OVERFLOW
"T" ADAPTER
MANUAL WATER DRAIN
BLOWER
INTERLOCK &
HUMIDISTAT CONN.
STATUS LIGHTS
AUTO DRAIN CONN.
FIG. 2
Parts included in the Steam Humidifier package are:
1. Self Piercing Saddle Valve
3. Mounting Templates x2
4. Installation Hardware package
5. Insulation and tape
6. Automatic Drain Assembly
7. Humidistat - Autoflo Models 062000 or 072000
8. 1/2” I.D. Drain Hose-8 FT.
9. Anode #Z 100
Copyright 1999-2003 EWC Controls All Rights Reserved.
C
Options and additional parts recommended:
1. Water Hammer Arrester #WH 100
2. Anode #Z 100
3. Decorative under duct cover # Sc100
4. Gasket Material to seal flanges (field provided)
P/N 094021A0099 Rev. J
SIMPLIFIED INSTALLATION INSTRUCTIONS
1. Insulate the water reservoir. See figure 3.
2. Select the mounting location on the duct and tape on the mounting template.
3. Drill the (8) 1/8" mountings holes.
4. Cut out the humidifier opening in the duct.
5. Insert the humidifier into the opening and screw in place.
If the humidifier installation does not meet the required criteria, consider using a different Autoflo model humidifier such as a SC15 or 200P.
6. Connect the water line.
7. Connect the drain line.
8. Make 24 VAC electrical connections to blower interlock.
9. Install and connect the humidistat.
10. Plug power cord into a grounded dedicated 120 VAC, 15 amp outlet for S2000 (240 VAC, 10 amp for S2020).
DETAILED INSTALLATION INSTRUCTIONS
1. INSULATE WATER TANK RESERVOIR
With insulation foil side down, remove adhesive backing. Align humidifier so that front side of unit meets long edge of insulation. Fold insulation up onto sides of humidifier and press firmly. Apply 5 continuous strips from the tape provided to seal the foil as shown. The tape will prevent the sharp duct edges from damaging the foil. Use additional foil tape to repair damage to the foil. The Insulation MUST be applied to the tank regardless of the mounting location.
INSULATION (FOIL SIDE OUT)
3. WEIGHT - Required Criteria
If the humidifier is installed on fiberglass duct, the installer must provide structural support for the unit.
The fiberglass duct alone will not support the weight of the steam humidifier, which is 9 Lbs. empty and 15 Lbs. when full of water. Providing Adequate Structural Support for this unit is the responsibility of the Installer
4. MOUNTING TEMPLATE
Two mounting templates are provided. Choose the correct template for your mounting method. Tape the mounting template to the duct. The template must be leveled using the top of the cutout on the template. The template should be located so that the bottom of the reservoir cut-out is flush with the inside of the bottom of the duct for horizontal duct. Since most ducts are insulated this additional space, about one (1) inch, must be accounted for when determining the location for the bottom of the reservoir cut-out. If you are mounting it under the duct, make sure the duct is level.
USE TAPE TO SEAL THE FOIL TO THE FRONT MOUNTING PLATE (3 PLACES-SIDES AND BOTTOM)
FIG. 3
USE TAPE TO SEAL THE OUTSIDE EDGE OF THE FOIL (2 PLACES)
2. LOCATION-LOCATION - Required Criteria
DO NOT INSTALL this unit in an attic unless freeze and flood protection measures are taken! See page 12
for details. The steam humidifier can be installed in either the warm air supply or the cold air return ducts; however the preferred location would be in the warm air supply duct of the heating system. This humidifier does not require warm air to evaporate the water in order to provide humidity, but it will operate more efficiently in the warm air duct and condensation is less likely to occur on the surrounding cold surfaces. Efficiency is lost in a return air duct location.
When selecting a location on the duct, be certain that there is enough room in the duct for the water reservoir. There should be at least five (5) inches above the reservoir and the reservoir should not occupy more than about 25 percent of the duct space. If this criteria can not be met, you should install the unit under the duct by means of the tank flange. A template is provided for installing the unit under the duct, on the cold air return.
A suitable means of gravity draining the unit should be available, Although the unit will work with the drain valve physically or electrically disconnected. See page 12.
5. DRILL HOLES AND CUT OPENINGS
Use an electric drill, with grounded power cord, to drill eight (8) mounting holes, 1/8" diameter, in the duct. These can be drilled through the template at the locations indicated on the template.
A saber saw or tin snips can be used to cut out the water reservoir opening.
CUT ON LINE
MOUNTING TEMPLATE
MODEL S2000 & S2020
CUT ON LINE
1. TAPE TEMPLATE IN LEVEL POSITION.
2. DRILL (8) HOLES FOR SHEET METAL SCREWS SHOWN ON TEMPLATE (DO NOT DRILL LARGER THAN 1/8" DIAMETER.
3. CUT OUT SOLID LINE AREA AS MARKED.
4. MOUNT HUMIDIFIER PER INSTRUCTIONS.
CUT ON LINE
2
CUT ON LINE
FIG. 4
P/N 094021B0037
6. WATER SUPPLY - Required Criteria
A. WATER SUPPLY USING THE SADDLE VALVE FURNISHED WITH UNIT
Installation instructions for the saddle valve are printed on the plastic bag containing the saddle valve and its components. Tap into a 1/2” or 3/4” domestic hot water line for best results, but a cold water line will do. Avoid connecting to water lines from a Reverse Osmosis system.
The supply water must read a minimum of 25 ppm in order for the Steam unit to reliably sense the water.
NOTE: Never install the saddle valve on the bottom of the water pipe. Sediment in the water pipe may clog the saddle valve. When tightening the hex compression nut,
tighten only enough to assure there are no leaks.
NOTE: Saddle valves do not meet plumbing codes in some areas. A “T” fitting with a valve may be required to meet code or, if low water pressure causes frequent water alerts on the steam humidifier.
NOTE: Do not use any line which is served by a water softener. If your home has a water softener, make the water connections to a water line upstream from the water softener. A water softener is not a demineralizer. It merely exchanges various hard ions for soft ions in the water. These soft ions, or minerals, will build up in the humidifier, causing the need for frequent servicing. The evaporation of softened water may also produce a white powder which may be carried into the duct system and, ultimately, into your home.
Note: Use a water hammer arrester (WH-100)
if water spikes occur during operation.
B. OVERFLOW & DRAIN LINES - Required Criteria
The use of an overflow line and drain line is always required.
Use the supplied 1/2” ID high temperature hose. Slip the hose over the 1/2” OD “T” drain fitting and use a hose clamp to secure. Route the hose to a suitable drain,
avoiding kinks, traps and sharp objects. DO NOT route the hose above the humidifier.
NOTE: Previous models required two [2] drain hoses.
The new models include an integrated overflow tube with a high temperature barbed “T” fitting. The new design simplifies the installation process.
Failure to install all necessary drain lines will result in water leaks during normal operating conditions, and voids all warranties.
7. M OUNTING THE STEAM HUMIDIFIER
Use gaskets to seal where the steam flanges contacts the ductwork. Place the humidifier reservoir into the opening in the duct and secure with eight (8) sheet metal screws.
NOTE: If the ductwork will not support the unit in a level position with the water pan full of water, the duct-work must be reinforced. Both steam models weigh approximately 9 Lbs. empty and approximately 15 Lbs. full of water.
8. STEAM OPERATION
Because of the high output of this Humidifier, it must not be operated in ducts or plenums without the blower operating. The steam humidifier is designed to be "Dominant" over the Heating-Air Conditioning System Blower. The "System" Blower will be operated by the humidifier, when humidity is required to meet the demand. A minimum of 800 cfm is required for proper
operation of the steam humidifier. Lower velocities will result in excessive condensation inside the duct.
A temperature sensor is mounted in the water reservoir of the humidifier. As the water temperature increases to about 170 degrees F, the computer closes a set of blower relay contacts. When the water cools to about 140 degrees F, the computer will open the relay contacts.
9. WIRING THE STEAM HUMIDIFIER
IMPORTANT: Dedicated fused circuits of the proper voltage and current ratings must be provided. All wiring must conform to local and national codes.
A. INSTALLING AND WIRING THE HUMIDISTAT
A humidistat, such as the AutoFlo Models 062000 or 072000 is required to control the Steam Humidifier. The humidistat may be installed on the wall in the living space or on the return air duct. NOTE: Continuos fan operation
should be initiated if the humidistat is installed on the return air duct! Instructions for installation are packaged
with the humidistat. DO NOT connect any foreign voltage to the “H” terminals
of the humidifier. The unit supplies it’s own 24 volt control voltage. Simply connect the two “H” terminals straight to the humidistat terminals.
S2000 & S2020 Typical Wiring and Blower Interlock Diagram
S2000 & S2020 Humidifier
Typical
Thermostat
G YWR
G YWR
Furnace
FIG. 5
B. FIELD WIRING
Heat & Cool System
G1 R G2 H H
Humidistat
All wiring must be made in accordance with local codes and ordinances. DO NOT cut off the grounded plug and/or hard wire this unit to line
voltage. Do not use extension cords to
operate this unit!
Figures 5 & 6 describes the suggested interlock wiring arrangement for HVAC systems. Interlocking may be performed on heating systems that provide a 24 VAC NEC Class 2 terminal for blower control.
IMPORTANT NOTE:
If the Steam Humidifier is removed and disconnected from the system, the
blower interlock circuit must be restored to it's original configuration. Failure to do so may result in loss of blower operation!
3
S2000 & S2020 Humidifier
Heat only
Thermostat
WR
GWR
Furnace
FIG. 6
Connect field wiring as shown in Figures 5 or 6.
IMPORTANT: If the humidifier is installed in the return air plenum the humidistat must be located at least three (3) feet upstream from the humidifier. Fan should be operated in continuos mode when humidistat is mounted in the return air plenum.
Heat Only System
G1 R G2 H H
Humidistat
10. SETTING THE HUMIDISTAT
It is recommended that humidistat settings of 30-40% not be exceeded. If condensation is noticed on windows during very cold outside temperatures, the humidistat setting should be lowered.
The maximum recommended relative humidity for your home depends upon factors such as outdoor air temperature, type and placement of insulation, vapor barriers, effectiveness of weather stripping, type of windows and doors (including frames and jambs) and whether or not storm windows and doors are used. With all these variables it is nearly impossible to recommend a proper humidity setting. The best humidistat setting is one that you are comfortable with. Also, as the outdoor temperature fluctuates, it may be necessary to adjust the humidity level of your system a few times during the heating season.
Refer to the "Relative Humidity Chart" as a starting point for your proper humidistat setting. Generally, in a tighter and better insulated house, the humidistat may be set higher than in a drafty, un-insulated house.
The humidistat has two (2) screw terminals which should be connected to the low-voltage interlock plug. (Figure 5).
Wiring instructions for the 072000 model Humidistat are packaged with the 072000.
RELATIVE HUMIDITY CHART
Outside Outside Temperature
-10 Deg. F
0 Deg. F
10 Deg. F
Relative
Humidity
40% 60% 80%
40% 60% 80%
40% 60% 80%
Indoor Relative
Humidity
When Outside
Air Is Heated To
72 Degrees F
1% 2% 2%
2% 2% 5%
4% 5% 7%
Maximum Safe
Recommended Indoor
Relative Humidity
20%
25%
30%
20 Deg. F
30 Deg. F
40% 60% 80%
40% 60% 80%
6% 8%
11%
8% 13% 17%
4
35%
40%
Loading...
+ 8 hidden pages