FiberPlex TIS-8632 User Manual

0 (0)
FiberPlex TIS-8632 User Manual

USER MANUAL

6 Port 10/100/1000 Ethernet Switch

TIS 8632

[Page Intentionally Left Blank]

Warning for Your Protection

1.Read these instructions.

2.Keep these instructions.

3.Heed all warnings.

4.Follow all instructions.

5.Do not use this apparatus near water.

6.Clean only with a dry cloth.

7.Do not block any of the ventilation openings. Install in accordance with the manufacturer’s instructions.

8.Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9.Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

10.Only use attachments/accessories specified by the manufacturer.

11.Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip over.

12.Unplug this apparatus during lightning storms or when unused for long periods of time.

13.Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

The apparatus shall not be exposed to dripping or splashing. No objects filled with liquids, such as vases, shall be placed on the apparatus. “WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.”

General Installation Instructions

Please consider these general instructions in addition to any product specific instructions in the “Installation” chapter of this manual.

Unpacking

Check the equipment for any transport damage. If the unit is mechanically damaged, if liquids have been spilled or if objects have fallen into the unit, it must not be connected to the AC power outlet, or it must be immediately disconnected by unplugging the power cable. Repair must only be performed by trained personnel in accordance with the applicable regulations.

Installation Site

Install the unit in a place where the following conditions are met:

The temperature and the relative humidity of the operating environment must be within the specified limits during operation of the unit. Values specified are applicable to the air inlets of the unit.

Condensation may not be present during operation. If the unit is installed in a location subject to large variations of ambient temperature (e.g. in an OB van), appropriate precautions must be taken.

Unobstructed air flow is essential for proper operation. Ventilation openings of the unit are a functional part of the design and must not be obstructed in any way during operation (e.g. by objects placed upon them, placement of the unit on a soft surface, or improper installation of the unit within a rack or piece of furniture).

The unit must not be unduly exposed to external heat sources (direct sunlight, spot lights).

Ambient Temperature

Units and systems by FiberPlex are generally designed for an ambient temperature range (i.e. temperature of the incoming air) of +5...+40 °C. When rack mounting the units, the following facts must be considered:

The permissible ambient temperature range for operation of the semiconductor components is 0 °C to +70 °C (commercial temperature range for operation).

The air flow through the installation must allow exhaust air to remain cooler than 70 °C at all times.

Average temperature increase of the cooling air shall be about 20 C°, allowing for an additional maximum 10 C° increase at the hottest components.

If the cooling function of the installation must be monitored (e.g. for illumination with spot lamps), the exhaust air temperature must be measured directly above the modules at several places within the enclosure.

Grounding and Power Supply

Grounding of units with mains supply (class I equipment) is performed via the protective earth (PE) conductor integrated in three pin Phoenix™ connector. Units with battery operation (< 60 V, class III equipment) must be earthed separately. Grounding the unit is one of the measures for protection against electrical shock hazard (dangerous body currents). Hazardous voltage may not only be caused by defective power supply insulation, but may also be introduced by the connected audio or control cables.

This equipment may require the use of a different line cord, attachment plug, or both, depending on the available power source at installation. If the attachment plug needs to be changed, refer servicing to qualified personnel.

Page 1

Warranty, Service and Terms and Conditions of Sale

For information about Warranty or Service information, please see our published ‘Terms and Conditions of Sale’. This document is available on fiberplex.com or can be obtained by requesting it from clients@fiberplex.com or calling 301.604.0100.

Disposal

Disposal of Packing Materials

The packing materials have been selected with environmental and disposal issues in mind. All packing material can be recycled. Recycling packing saves raw materials and reduces the volume of waste. If you need to dispose of the transport packing materials, recycling is encouraged.

Disposal of Used Equipment

Used equipment contains valuable raw materials as well as substances that must be disposed of professionally. Please dispose of used equipment via an authorized specialist dealer or via the public waste disposal system, ensuring any material that can be recycled has been. Please take care that your used equipment cannot be abused. After having disconnected your used equipment from the mains supply, make sure that the mains connector and the mains cable are made useless.

Disclaimer

The information in this document has been carefully checked and is believed to be accurate at the time of publication. However, no liability is assumed by FiberPlex for inaccuracies, errors, or omissions, nor for loss or damage resulting either directly or indirectly from use of the information contained herein.

Page 2

Introduction

Elegantly simple yet packed with an advanced feature set, the FiberPlex Technologies TIS 8632 is a powerful 6 Port 10/100/1000 Ethernet Switch. The unit interfaces UTP RJ 45 jacks (x4) to variously populated SFP positions.

Key Features

6 Ports – (4) 10/100/1000BASE T Copper and (2) 1000BASE X Optical

Flow control for full duplex and half duplex

Supports up to 10k byte JUMBO frame

Supports Ports Based VLANS and TAG Based VLANS

Conforms to FCC and CE codes

Includes power adapter as well as a 3 position Phoenix™ connector

The TIS 8632 is housed in the commercial ‘Throw Down’ packaging. This version is designed to be a work horse unit in various commercial and industrial environments. It is powered either by a 9VDC ‘Wall Wart’ style supply (included) or via bussed power supplied through an integrated three pin Phoenix™ connector. Up to three TIS 8632 units can be installed in the optional 1U TDR 01 rack shelf.

Standard Ordering Options

TIS 8632 C – Unit with no SFP modules included

TIS 8632 L22 – Unit with (2) 1310 nm Multimode SFP modules (SFP MC24XC 3131 2) included. Conforms to IEEE 1000BASE LX standard.

TIS 8632 L5B – Unit with (2) 1310 nm Singlemode SFP Modules (SFP SC24XC 3131 B) included. Conforms to IEEE 1000BASE LX10 standard.

Getting Started

Initial Inspection

Immediately upon receipt, inspect the shipping container for damage. The container should be retained until the shipment has been checked for completeness and the equipment has been checked mechanically and electrically. If the shipment is incomplete, if there is mechanical damage, or if the unit fails to operate notify FiberPlex and make the shipping materials available for the carrier's inspection.