Please hire a plumber or Qulified Installer
not use this product if you cannot follow these instructions.
The Verona Burner System is designed, and intended, for installation in an existing approved, fully vented, wood-burning fireplace, which includes gas hook-up. Gas Control Valve units may be fueled by, either Natural Gas or Liquid Propane. Liquid Propane must be orderd as such, DO NOT Connect the Unit with any fuel other than is intended !
ANY REASON WHATSOEVER
DO NOT INSTALL IN A WOOD BURNING STOVE NEVER OPERATE WITH CLOSED GLASS DOORS !
These instructions are intended as a general guide and do not supersede national or local codes in any way. Authorities having jurisdiction should be consulted before installation.
Installation and provision for combustion and ventilation air must conform to the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, or CAN/CGA-B149.1, Natural Gas Installation Code, or CAN/CGA-B149.2, Propane Installation Code.
.
GENERAL INFORMATION
!!! IMPORTANT !!!
Read these instructions carefully before installing or operating this gas appliance. These instructions should be left with the homeowner for future reference.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Gas Burner System
³3/($6(´ do
!!! WARNING !!!
LLC.
WHAT TO DO IF YOU SMELL GAS:
< Do not try to light any appliance.
< Do not touch any electrical switch; do not use
any phone in your building.
< Immediately call your gas supplier from a
QHLJKERU¶VSKRQH. Follow the gas sXSSOLHU¶V instructions.
< If you can not reach your gas supplier, call the
fire department.
Do not store combustible materials or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a: Qualified technician, service agency, or the gas supplier.
Your unit was test fired and Inspected prior to shipment.
Any discoloration on the Burner or pilot is due to the test fire
!!! WARNING !!!
This appliance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of non­combustible materials. This unit is NOT for use with solid fuel. Solid fuels shall NOT be burned in a fireplace where a decorative appliance is installed.
!!! DANGER !!!
NEVER OPERATE THIS APPLIANCE WITH
1
FIREPLACE GLASS DOORS CLOSED !
SAFETY INFORMATION
<
<
<
<
<
<
<
<
<
Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance.
During manufacturing, fabrication, and shipping, various components of this appliance are treated with certain oils, films, or bonding agents. These chemicals ARE NOT harmful, but may produce annoying smoke and smells, as they are burned off, during the initial operation of the appliance. This may possibly cause headaches, and eye or lung irritation. This is a normal and temporary occurrence. The initial break-in period should last three ( 3 ) to four ( 4 ) hours. During this period, provide maximum ventilation by opening a window or door, to allow odors to dissipate. Any odor remaining after this initial break-in period, will be slight and will disappear with continued use.
DO NOT USE SAND OR ANY OTHER GRANULAR MATERIAL AS A BURNER MEDIUM! USE ONLY THE APPROVED MEDIUM, EITHER PROVIDED, OR AS AN APPROVED ACCESSORY.
PROPER CLEARANCES FROM COMBUSTIBLE CONSTRUCTION AND MATERIALS MUST BE MAINTAINED FROM ALL SIDES, TOP, AND BOTTOM OF THIS APPLIANCE.
THIS APPLIANCE SHOULD NEVER BE PLACED NEAR ANY COMBUSTIBLE SURFACE.
THIS APPLIANCE SHOULD NEVER BE PLACED UNDER ANY COMBUSTIBLE CONSTRUCTION OR MATERIALS.
NEVER PLACE ANY COMBUSTIBLE MATERIAL WITHIN 24" OF THE
WARNING
manual, prior to operation.
WARNING: Fuels used in gas or oil ± fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects, and/or other reproductive harm. This warning is issued pursuant to California Health & Safety Code Sec.
25249.6.
While this appliance is not in use, the gas must be turned off at the gas supply.
DO NOT GAS FITTING WHILE THIS APPLIANCE IS IN OPERATION.
NEVER while in operation.
NEVER appliance.
NEVER decorative gas appliance.
NEVER
DO NOT appliance.
: Follow all gas leak check procedures in this
ATTEMPT TO DISCONNECT THE GAS OR ANY
leave this decorative gas appliance unattended
allow children to operate this decorative gas
place hands or fingers on the front edge of this
use liquid propane gas in a natural gas unit.
use solid-fuel or lighter fluid in any decorative gas
!!! WARNING !!!
FIREPLACE ENCLOSURE.
2
!!! WARNING !!!
The damper clamp, must be installed, in a manner, which will maintain the minimum permanent damper vent opening at all times. SEE FIGURE 1. See the Decorative Hearth System Specifications on page 3.
!!! WARNING !!!
The State of Massachusetts requires that the chimney flue damper, when used with decorative gas appliances, be welded open or completely removed. In the Commonwealth of Massachusetts, this appliance must be installed by a licensed plumber or gasfitter.
!!! WARNING !!!
Improper installation, adjustment, alteration, service or maintenance, can cause property damage, personal injury or
ORVVRIOLIH5HIHUWRWKHRZQHU¶VLQIRUPDWLRQPDQXDOSURYLGHG
with this appliance. Installation and service, must be performed, by a qualified installer, service agency or the gas supplier.
HIGH ALTITUDE DERATE
In the U.S.A., input BTU shall be de-rated 4% ( 1 orifice size ) per 1000 ft. for altitudes above 2000 ft.. In Canada, input BTU shall be de-rated 10% ( 2 orifice sizes ) at altitudes from 2000 ft. to 4500 ft..
A Front Width = Minimum 6" larger than unit size
B Center Width = Not Less than unit size
C Depth = All Verona Burners are 8.5 inches deep
D Height = Minimum 16"
3
Flue Damper Clamp NOT OPTIONAL !
FIGURE 1
INSTALLATION
LOCATION
This appliance, must be installed only in a solid-fuel burning fireplace, with a working flue, and constructed of noncombustible materials.
!!! IMPORTANT !!!
Before installing this appliance, have the fireplace and chimney, professionally cleaned, to remove any ashes, soot, creosote, or other obstructions. Perform this cleaning annually, after installation.
!!! IMPORTANT !!!
Seal any fresh air vents or ash clean-out doors located on the floor or wall of the fireplace. If this is not performed, drafting may cause pilot outage or sooting. Use a heat-resistant sealant; DO NOT seal the chimney flue damper.
!!! WARNING !!!
Gas supply system must be installed in accordance with the U.S. National Fuel Gas Code.
This appliance and its individual shut off valve must be disconnected from the gas supply piping system during any system pressure test in excess of ! PSI ( 3.5 KPA ).
Use a system manual shut off valve to shut off the gas supply to this gas appliance before continuing with
procedures.
installation
FIGURE 2
VERONA 3
BURNER SYSTEM
FRONT VIEW
NEVER OPERATE UNIT WITHOUT MEDIA ON BURNER
The Burner May warp and will not be covered under warranty.
FIGURE 3 ±
VERONA
BURNER SYSTEM
NOTE: Verona 23" and 30 " are a single Burner. Verona 42" is A double Burner system, All Co ntrols and functions are the same.
WHEN INSTALLING THE APPLIANCE, DO NOT
VERONA 42
OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION AIR.
BURNER SYSTEM FRONT VIEW
4
Loading...