Appliance features and installation requirements
Installation niche features: Integrated
Installation niche features: Classic
Installation niche features: StandPlus
Installation niche features: X-Pro
Installation niche features: Country
Installation niche features: Brilliance-Integrated
Installation niche features: Brilliance-Classic
Preparing to install
Transport to installation site and unpacking
Electrical and Water connection
Levelling
Panels mounting
Decorative door and Bottom-Drawer panels layout
Decorative panels layout for Fridge with one Bottom-Drawer (1T/0T)
Decorative panels layout for Fridge Brilliance
Decorative panels layout for Fridge with two Bottom-Drawers (0H)
Decorative panels layout for Fridge with Glass door and one Bottom-Drawer (1T/0T)
Decorative panels layout for Fridge with Glass door Brilliance
Decorative panels layout for Fridge with Glass door and two Bottom-Drawers (0H)
Decorative panels layout for Fridge Column (0F)
Decorative panels layout for Fridge column with glass door (0F)
Panels Dimensions One Bottom - Drawer (1T/0T models)
Panels Dimensions Two Bottom - Drawers (0H models)
Panels Dimensions Column model (0F models)
Mounting the handles
Mounting panels to the door and the drawer
EN
Installation
Built-in installation of single appliance
Built-in installation of two or more appliances
Free-standing installation two or more appliances
Completing the installation
Anti-tipping safety assembly
Mounting the handles on stainless front
Ventilation
Post installation control
Start Up
www.fhiaba.com · info@fhiaba.com · Tel +39 (0)434 420160 · Fax +39 (0)434 420161
33
Important safely instruction
Symbols used in the Guide
Note
Tips for the correct use of the appliance
Important
Directions to avoid appliance damage
Warning
directions to prevent injury
Children safety
If this appliance is replacing an existing appliance which must be removed or disposed of, make sure that it does not become a dangerous trap for children by cutting its power supply cable and rendering it impossible to close the door. Use the same caution at the end of the lifespan of the new appliance.
IMPORTANT
Dimensions in parentheses are in inches.
Weights in parentheses are in pounds.
Temperatures in parentheses are in Fahrenheit degrees.
www.fhiaba.com · info@fhiaba.com · Tel +39 (0)434 420160 · Fax +39 (0)434 420161
34
Appliance dimensions
Integrated
Installation Guide
Appliance features and installation requirements
599 Series w: 599 mm (23 5/8”)/ h: 2050 mm (80 3/4”)/ d: 610 mm (24”) 749 Series w: 749 mm (29 1/2”)/ h: 2050 mm (80 3/4”)/ d: 610 mm (24”) 899 Series w: 899 mm (35 3/8”)/ h: 2050 mm (80 3/4”)/ d: 610 mm (24”)
Appliance dimensions
Classic
Appliance dimensions
StandPlus
Appliance dimensions
X-Pro / Country
Appliance dimensions
Brilliance-Integrated
Appliance dimensions
Brilliance-Classic
Appliance dimensions
Integrated / Classic
Appliance dimensions
StandPlus / X-Pro / Country
Weight with packaging
Voltage
599 Series w: 599 mm (23 5/8”)/ h: 2050 mm (80 3/4”))/ d: 635 mm (25”) 749 Series w: 749 mm (29 1/2”)/ h: 2050 mm (80 3/4”))/ d: 635 mm (25”) 899 Series w: 899 mm (35 3/8”)/ h: 2050 mm (80 3/4”))/ d: 635 mm (25”)
599 Series w: 599 mm (23 5/8”)/ h: 2120 mm (83 1/2”)/ d: 629 mm (24 3/4”) 749 Series w: 749 mm (29 1/2”)/ h: 2120 mm (83 1/2”)/ d: 629 mm (24 3/4”) 899 Series w: 899 mm (35 3/8”)/ h: 2120 mm (83 1/2”)/ d: 629 mm (24 3/4”)
599 Series w: 599 mm (23 5/8”)/ h: 2120 mm (84”)/ d: 635 mm (25”) 749 Series w: 749 mm (29 1/2”)/ h: 2120 mm (84”)/ d: 635 mm (25”) 899 Series w: 899 mm (35 3/8”)/ h: 2120 mm (84”)/ d: 635 mm (25”)
599 Series w: 599 mm (23 5/8”)/ h: 2050 mm (80 3/4”)/ d: 575 mm (22 5/8”) 749 Series w: 749 mm (29 1/2”)/ h: 2050 mm (80 3/4”)/ d: 575 mm (22 5/8”) 899 Series w: 899 mm (35 3/8”)/ h: 2050 mm (80 3/4”)/ d: 575 mm (22 5/8”)
599 Series w: 599 mm (23 5/8”)/ h: 2050 mm (80 3/4”))/ d: 600 mm (23 3/4”) 749 Series w: 749 mm (29 1/2”)/ h: 2050 mm (80 3/4”))/ d: 600 mm (23 3/4”) 899 Series w: 899 mm (35 3/8”)/ h: 2050 mm (80 3/4”))/ d: 600 mm (23 3/4”)
599 Series w: 650 mm (25 5/8”) / h: 2210 mm (87”)/ d: 800 mm (31 1/2”) 749 Series w: 800 mm (31 1/2”)/ h: 2210 mm (87”)/ d: 800 mm (31 1/2”) 899 Series w: 950 mm (37 3/8”) / h: 2210 mm (87”)/ d: 800 mm (31 1/2”)
599 Series w: 650 mm (25 5/8”) / h: 2260 mm (89”) / d: 800 mm (31 1/2”) 749 Series w: 800 mm (31 1/2”) / h: 2260 mm (89”) / d: 800 mm (31 1/2”) 899 Series w: 950 mm (37 3/8”) / h: 2260 mm (89”) / d: 800 mm (31 1/2”)
599 Series up to 230 kg (507 lb) 749 Series up to 275 kg (606 lb) 899 Series up to 295 kg (650 lb)
Europe Version: AC 220-240V 50 Hz / North America Version: 110V 60Hz
EN
Power supply cable
Potable water supply pressure
Water supply tube
Provided installation accessories
Additional equipment necessary
Europe Version: Schuko 16 A plug / North America Version: 15 A
from 0.05 MPa to 0.5 MPa (0.5 Bar - 5 Bar)
3/4” female attachment
Customized panels mounting Kit Anti-tipping Kit (B04000200) Lateral connecting kit (KCLIT/KCLIH) 4 mm (1/8”) allen wrench Phillips head screwdriver wood and percussion drill
2.5 mm (1/8”) bit for wood 8 mm (3/8”) bit for walls 17 mm (3/4”) wrench
www.fhiaba.com · info@fhiaba.com · Tel +39 (0)434 420160 · Fax +39 (0)434 420161
35
S899: 1470 (57 7⁄8”)
10 (3⁄8”)
231 (9
233 (9
330 (13”)
259 (10
¼”
)
min 2064 (81 ¼”)
140 (5 ½”) 140 (5 ½”)
Installation niche features: Integrated Series
A
area to be left clear for the anti-tipping brackets
area to be left clear for the anti-tipping brackets
E
area to be left clear for the power supply cable
area to be left clear for the power supply cable
W
and water supply hose
and water supply hose
Minimum Niche Height
Minimum Niche Height
2064 mm (81 1/4”)
Minimum Niche Width
Minimum Niche Width
S899: 900 mm (35 1/2”) S749: 750 mm (29 5/8”) S599: 600 mm (23 3/4”)
Door Swing Clearance
Door Swing Clearance
S899: 1470 mm (57 7/8”) S749: 1320 mm (52”) S599: 1170 mm (46”)
100 (4”)
A A
899 900 (35 ½”)
749 750 (29 5⁄8”)
599 600 (23 ¾”)
E W E W
1T/0T
100 (4”)
610 (24”)
560 (22”)
15 (5⁄8”)
Door Opening Angle
105°
Width
S899: 899 mm (35 3/8”) S749: 749 mm (29 1/2”) S599: 599 mm (23 5/8”)
Height
2050 mm (80 3/4”) + 25 mm (1”)
Depth with door (without panel)
610 mm (24”)
Important: A 90° door opening is sufcient to allow
opening and full extraction of the inner drawers, even if the appliance is installed directly adjacent to a wall. Should an opening at 105° be desired, then the ap­pliance should be positioned at the distance from the
wall described in gure.
S899: 160 (6 3⁄8”) S749: 125 (5”) S599: 90 (3 ½”)
560 (22”)
610 (24”)
992 (39”)
S749: 1320 (52”)
S599: 1170 (46”)
105°
S899: 899 (35 3⁄8”) S749: 749 (29 ½”) S599: 599 (23 5⁄8”)
1293 (50 7⁄8” )
2050 (80 ¾”) +25 (1”)
721 (28 3⁄8”) +25 (1”)
0H
2050 (80 ¾”) +25 (1”)
846 (33 ¼”) +25 (1”)
0F
2050 (80 ¾”) +25 (1”)
500 (19 ¾”)
610 (24”) 560 (22”)
500 (19 ¾”)
610 (24”)
560 (22”)
20 (¾”)
474 (18 5⁄8”)
25 (1”)
+ 25 (1”)
) +
)
1⁄8”
¾”
231 (9
248 (9
15 (5⁄8”)
1168(46”)
20 (¾”)10 (3⁄8”)
25 (1”)
+ 25 (1”)
) +
)
1⁄8”
¾”
231 (9
248 (9
15 (5⁄8”)
1808 (71 ¼” )
500 (19 ¾”)
www.fhiaba.com · info@fhiaba.com · Tel +39 (0)434 420160 · Fax +39 (0)434 420161
36
25 (1”)
+ 25 (1”)
) +
)
1⁄8”
¼”
min 2064 (81 ¼”)
140 (5 ½”) 140 (5 ½”)
342 (13 ½”)362 (14 ¼”)
KS899: 1470 (57 7⁄8”)
10 (3⁄8”)
58 (2 ¼”)
Installation Guide
Installation niche features: Classic Series
A
area to be left clear for the anti-tipping brackets
E
area to be left clear for the power supply cable
W
and water supply hose
100 (4”)
Minimum Niche Height
2064 mm (81 1/4”)
Minimum Niche Width
KS899: 900 mm (35 1/2”) KS749: 750 mm (29 5/8”) KS599: 600 mm (23 3/4”)
Door Swing Clearance
KS899: 1470 mm (57 7/8”) KS749: 1320 mm (52”) KS599: 1170 mm (46”)
A A
KS899: 900 (35 ½”)
KS749: 750 (29 5⁄8”)
KS599: 600 (23 ¾”)
E W E W
1T/0T
100 (4”)
EN
635 (25”)
560 (22”)
Door Opening Angle
105°
Width
KS899: 899 mm (35 3/8”) KS749: 749 mm (29 1/2”) KS599: 599 mm (23 5/8”)
Height
2050 mm (80 3/4”) + 25 mm (1”)
Depth with door
635 mm (25”)
Important: A 90° door opening is sufcient to allow
opening and full extraction of the inner drawers, even if the appliance is installed directly adjacent to a wall. Should an opening at 105° be desired, then the ap­pliance should be positioned at the distance from the
wall described in gure.
KS899: 230 (9) KS749: 195 (7 ¾”) KS599: 160 (6 ¼”)
1016 (40”)
KS749: 1320 (52”)
KS599: 1170 (46”)
105°
635 (25”)
560 (22”)
75 (3”)
KS899: 899 (35 3⁄8”) KS749: 749 (29 ½”) KS599: 599 (23 5⁄8”)
2050 (80 ¾”) +25 (1”)
732 (28 7⁄8”)+25 (1”)
2050 (80 ¾”) +25 (1”)
857 (33 ¾”) +25 (1”)
2050 (80 ¾”) +25 (1”)
1308 (51 ½”)587 (23 1⁄8”)146 (5 ¾”) + 25(1”)
9 ( 3⁄8”)
693 (27 ¼”)
635 (25”)
0H
0F
560 (22”)
693 (27 ¼”)
635 (25”)
560 (22”)
1185 (46 5⁄8”)
9 ( 3⁄8”)6 ( ¼”)
146 (5 ¾”) + 25(1”)
1904 (75)
693 (27 ¼”)
www.fhiaba.com · info@fhiaba.com · Tel +39 (0)434 420160 · Fax +39 (0)434 420161
¾”) + 25(1”)
37
min 10
140 (5 ½”) 140 (5 ½”)
min 2134 (84”)
128 (5)
+ 25 (1”
749 (29 ½”) + 25 (1”)
3⁄8
37 (1 ½”)
MS899: 1470 (57 7⁄8”)
MS749: 1320 (52”
MS599: 1170 (46”
Installation niche features: StandPlus Series
A
area to be left clear for the anti-tipping brackets
E
area to be left clear for the power supply cable
W
and water supply hose
Minimum Niche Height
2134 mm (84”)
Minimum Niche Width
MS899: 900 mm (35 1/2”) MS749: 750 mm (29 5/8”) MS599: 600 mm (23 3/4”)
Door Swing Clearance
MS899: 1470 mm (57 7/8”) MS749: 1320 mm (52”) MS599: 1170 mm (46”)
Door Opening Angle
105°
100 (4”)
A A
MS899: 900 (35 ½”)
MS749: 750 (29 5⁄8”)
MS599: 600 (23 ¾”)
E W E W
1T/0T
100 (4”)
629 (24 ¾”) 615 (24 ¼”)
8 (3⁄8”)
195 (7 5⁄8”)
1296 (50”)
Width
MS899: 899 mm (35 3/8”) MS749: 749 mm (29 1/2”) MS599: 599 mm (23 5/8”)
Height
2120 mm (83 1/2”) + 25 mm (1”)
Depth with door
629 mm (24 3/4”)
2120 (83 ½”) +25 (1”)
613 (24 1⁄8”)+25 (1”)
8 (3⁄8”)
485 (19 1⁄8”)
560 (22”) 666 (26 ¼”)
0H
629 (24 ¾”) 615 (24 ¼”)
128 (5)
+ 25 (1”)
8 (3⁄8”)
195 (7 5⁄8”)
Important: A 90° door opening is sufcient to allow
opening and full extraction of the inner drawers, even if the appliance is installed directly adjacent to a wall.
1170 (46”)
Should an opening at 105° be desired, then the ap­pliance should be positioned at the distance from the
wall described in gure.
Important: If the units are to be installed inside a ni-
2120 (83 ½”) +25 (1”)
8 (3⁄8)
343 (13 ½”)
6 ( ¼”)
che or within an enclosed structure, it is necessary to design a ventilation shaft at the back of the niche to assure proper ventilation at the back of the unit.
MS899: 230 (9) MS749: 195 (7 ¾”)
)
)
1010 (39 ¾”)
105°
MS599: 160 (6 ¼”)
560 (22”)
629 (24 ¾”)
69 (2 ¾”)
MS899: 899 (35 3⁄8”)
MS749: 749 (29 ½”)
MS599: 599 (23 5⁄8”)
560 (22”) 666 (26 ¼”)
”)
10 (
min 50 (2”)
262 (10 ¼”)
)
(3⁄8”)
38
www.fhiaba.com · info@fhiaba.com · Tel +39 (0)434 420160 · Fax +39 (0)434 420161
A
140 (5 ½”) 140 (5 ½”)
min 2134 (84”)
749 (29 ½”) + 25 (1”
XS899: 1470 (57 7⁄8”)
area to be left clear for the anti-tipping brackets
E
area to be left clear for the power supply cable
W
and water supply hose
Installation Guide
Installation niche features: X-Pro Series
100 (4”)
A A
100 (4”)
Minimum Niche Height
2134 mm (84”)
Minimum Niche Width
XS899: 900 mm (35 1/2”)
XS899: 900 (35 ½”)
XS749: 750 (29 5⁄8”)
XS599: 600 (23 ¾”)
EN
XS749: 750 mm (29 5/8”) XS599: 600 mm (23 3/4”)
E W E W
Door Swing Clearance
XS899: 1470 mm (57 7/8”) XS749: 1320 mm (52”) XS599: 1170 mm (46”)
1T/0T
635 (25)
8 (3⁄8”)
195 (7 5⁄8”)
Door Opening Angle
105°
Width
XS899: 899 mm (35 3/8”) XS749: 749 mm (29 1/2”)
2120 (83 ½”) +25 (1”)
XS599: 599 mm (23 5/8”)
613 (24 1⁄8”)+25 (1”)
Height
560 (22”)
693 (27 ¼”)
1296 (50”)
8 (3⁄8”)
516 (20 3⁄8”)
+ 25 (1”)
97 (3 7⁄8”)
2120 mm (83 1/2”) + 25 mm (1”)
0H
Depth with door
635 mm (25 ”)
Important: A 90° door opening is sufcient to allow
opening and full extraction of the inner drawers, even if the appliance is installed directly adjacent to a wall. Should an opening at 105° be desired, then the ap­pliance should be positioned at the distance from the
wall described in gure.
Important: If the units are to be installed inside a ni­che or within an enclosed structure, it is necessary to design a ventilation shaft at the back of the niche to assure proper ventilation at the back of the unit.
XS899: 230 (9) XS749: 195 (7 ¾”) XS599: 160 (6 ¼”)
1016 (40”)
XS749: 1320 (52”)
XS599: 1170 (46”)
105°
635 (25”)
560 (22”)
75 (3”)
XS899: 899 (35 5⁄8”)
XS749: 749 (29 ½”)
XS599: 599 (23 5⁄8”)
195 (7 5⁄8”)
8 (3⁄8”)
1170 (46”)
2120 (83 ½”) +25 (1”)
)
10 (3⁄8”)58 (2 ¼”)
8 (3⁄8”)
6 ( ¼”)
343 (13 ½”)
293
(11 ½”)
+ 25 (1”)
97 (3 7⁄8”)
min 50 (2”)
min 10 (3⁄8”)
www.fhiaba.com · info@fhiaba.com · Tel +39 (0)434 420160 · Fax +39 (0)434 420161
39
140 (5 ½”) 140 (5 ½”)
min 2134 (84”)
+ 25 (1”)
AS899: 1470 (57 7⁄8”)
Installation niche features: Country Series
A
area to be left clear for the anti-tipping brackets
E
area to be left clear for the power supply cable
W
and water supply hose
100 (4”)
A A
100 (4”)
Minimum Niche Height
2134 mm (84”)
Minimum Niche Width
AS899: 900 mm (35 1/2”) AS749: 750 mm (29 5/8”) AS599: 600 mm (23 3/4”)
Door Swing Clearance
AS899: 1470 mm (57 7/8”) AS749: 1320 mm (52”) AS599: 1170 mm (46”)
Door Opening Angle
105°
Width
AS899: 887 mm (35") AS749: 737 mm (29") AS599: 587 mm (23 1/8")
Height
2120 mm (83 1/2”) + 25 mm (1”)
AS899: 900 (35 ½”)
AS749: 750 (29 5⁄8”)
AS599: 600 (23 ¾”)
E W E W
1T/0T
2120 (83 ½”) +25 (1”)
613 (24 1⁄8”)+25 (1”)
635 (25)
560 (22”) 695 (27 ¼”)
8 (3⁄8”)
195 (7 5⁄8”)
1296 (50”)
8 (3⁄8”)
485 (19 1⁄8”)
128 (5)
Depth with door
635 mm (25 ”)
Important: A 90° door opening is sufcient to allow
opening and full extraction of the inner drawers, even if the appliance is installed directly adjacent to a wall. Should an opening at 105° be desired, then the ap­pliance should be positioned at the distance from the
wall described in gure.
AS899: 230 (9) AS749: 195 (7 ¾”) AS599: 160 (6 ¼”)
1016 (40”)
AS749: 1320 (52”)
AS599: 1170 (46”)
105°
635 (25”)
560 (22”)
75 (3”)
AS899: 887 (35”)
AS749: 737 (29”)
AS599: 587 (23 1⁄8”)
10 (3⁄8”)60 (2 ¼”)
min 50 (2”)
min 10 (3⁄8”)
www.fhiaba.com · info@fhiaba.com · Tel +39 (0)434 420160 · Fax +39 (0)434 420161
40
140 (5 ½”) 140 (5 ½”)
min 2064 (81 ¼”)
231 (9
248 (9
BI899: 1435 (56 ½”)
3⁄8
A
area to be left clear for the anti-tipping brackets
E
area to be left clear for the power supply cable
W
and water supply hose
Minimum Niche Height
2064 mm (81 1/4”)
Minimum Niche Width
BI899: 900 mm (35 1/2”) BI749: 750 mm (29 5/8”) BI599: 600 mm (23 3/4”)
Installation Guide
Installation niche features: Brilliance-Integrated Series
100 (4”)
A A
BI899: 900 (35 ½”)
BI749: 750 (29 5⁄8”)
BI599: 600 (23 ¾”)
100 (4”)
EN
Door Swing Clearance
BI899: 1435 mm (56 1/2” in) BI749: 1285 mm (50 5/8” in) BI599: 1135 mm (44 3/4” in)
Door Opening Angle
105°
Width
BI899: 899 mm (35 3/8”) BI749: 749 mm (29 1/2”) BI599: 599 mm (23 5/8”)
Height
2050 mm (80 3/4”) + 25 mm (1”)
Depth with door (without panel)
575 mm (22 5/8” in)
Important: A 90° door opening is sufcient to allow
opening and full extraction of the inner drawers, even if the appliance is installed directly adjacent to a wall. Should an opening at 105° be desired, then the ap­pliance should be positioned at the distance from the
wall described in gure.
E W E W
0T
2050 (80 ¾”) +25 (1”)
721 (28 3⁄8”) +25 (1”)
575 (22 5⁄8”)
525 (20 5⁄8”)
465 (18 3⁄8”)
15 (5⁄8”)
1293 (50 7⁄8” )
20 (¾”)
474 (18 5⁄8”)
25 (1”)
+ 25 (1”)
) +
)
1⁄8”
¾”
BI899: 160 (6 3⁄8”) BI749: 125 (5”) BI599: 90 (3 ½”)
525 (20 5⁄8”)
575 (22 5⁄8”)
947 (37 ¼”)
BI749: 1285 (50 5⁄8”)
BI599: 1135 (44 ¾”)
105°
BI899: 899 (35 3⁄8”) BI749: 749 (29 ½”) BI599: 599 (23 5⁄8”)
”)
10 (
www.fhiaba.com · info@fhiaba.com · Tel +39 (0)434 420160 · Fax +39 (0)434 420161
41
140 (5 ½”) 140 (5 ½”)
min 2064 (81
¼”)
146 (5
BKI899: 1435 (56 ½”)
BKI749: 1285 (50
BKI599: 1135 (44
10 (3⁄8”)
58 (2 ¼”)
Installation niche features: Brilliance-Classic Series
A
area to be left clear for the anti-tipping brackets
E
area to be left clear for the power supply cable
W
and water supply hose
100 (4”)
A A
100 (4”)
Minimum Niche Height
2064 mm (81 1/4”)
Minimum Niche Width
BKI899: 900 mm (35 1/2”) BKI749: 750 mm (29 5/8”) BKI599: 600 mm (23 3/4”)
Door Swing Clearance
BKI899: 1435 mm (56 1/2” in) BKI749: 1285 mm (50 5/8” in) BKI599: 1135 mm (44 3/4” in)
Door Opening Angle
105°
Width
BKI899: 899 mm (35 3/8”) BKI749: 749 mm (29 1/2”) BKI599: 599 mm (23 5/8”)
Height
2050 mm (80 3/4”) + 25 mm (1”)
BKI899: 900 (35 ½”)
BKI749: 750 (29 5⁄8”)
BKI599: 600 (23 ¾”)
E W E W
0T
2050 (80 ¾”) +25 (1”)
732 (28 7⁄8”)+25 (1”)
600 (23 ¾”)
525 (20 5⁄8”)
693 (27 ¼”)
1308 (51 ½”)587 (23 1⁄8”)
9 ( 3⁄8”)
¾”) + 25(1”)
Depth with door
600 mm (23 3/4” in)
Important: A 90° door opening is sufcient to allow
opening and full extraction of the inner drawers, even if the appliance is installed directly adjacent to a wall. Should an opening at 105° be desired, then the ap­pliance should be positioned at the distance from the
wall described in gure.
BKI899: 230 (9) BKI749: 195 (7 ¾”) BKI599: 160 (6 ¼”)
5⁄8”)
¾”)
105°
600 (23 ¾”)
525 (20 5⁄8”)
75 (3”)
BKI899: 899 (35 3⁄8”) BKI749: 749 (29 ½”) BKI599: 599 (23 5⁄8”)
42
www.fhiaba.com · info@fhiaba.com · Tel +39 (0)434 420160 · Fax +39 (0)434 420161
Loading...
+ 22 hidden pages