FG Wilson P16.5-6S User Manual

#DEALER_LOGO
P16.5-6S
Output Ratings
Voltage, Frequency Prime Standby
#FGWILSON_GENSET_IMAGE
230 V, 50 Hz
240/120 V, 60 Hz
Ratings at 1 power factor. Please refer to the output ratings technical data section for specic generator set outputs per voltage.
kVA 15 16.5 kW 15 16.5 kVA 17.6 19.4 kW 17.6 19.4
Length mm Width mm 620 (24.4) Height mm Weight (Dry) kg Weight (Wet) kg 454 (1001)
Ratings in accordance with ISO 8528, ISO 3046, IEC 60034,
Generator set pictured may include optional accessories.
Prime Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
1500 (59.1)
1115 (43.9) 447 (985)
BS5000 and NEMA MG-1.22.
Standby Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as dened in ISO 8528-3).
Standard Reference Conditions
Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specic gravity of 0.85 and conforming to BS2869: 1998, Class A2.
FG Wilson oer a range of optional features to allow you to tailor our generator sets to meet your power needs. Options available include:
Upgrade to CE Certication
A wide range of Sound Attenuated Enclosures
A variety of generator set control and synchronising panels
Additional alarms and shutdowns
A selection of exhaust silencer noise levels For further information on all of the standard and optional features accompanying this product please contact your local Dealer or visit:
www.fgwilson.com
P16.5-6S
Ratings and Performance Data
Engine Make Engine Model: Alternator Make Alternator Model: Control Panel: Base Frame: Circuit Breaker Type: Frequency: Engine Speed: RPM rpm Fuel Tank Capacity: litres (US gal) Fuel Consumption Prime litres (US gal)/hr Fuel Consumption Standby litres (US gal)/hr
Engine Technical Data
No. of Cylinders Alignment Cycle Bore mm (in) Stroke mm (in) Induction Cooling Method Governing Type Governing Class Compression Ratio Displacement L (cu. in) Moment of Inertia: kg m² (lb/in²) Voltage Ground Battery Charger Amps Engine Weight Dry kg (lb) Engine Weight Wet kg (lb)
Perkins 404D-22G Leroy Somer LLB1114M FG100 Heavy Duty Fabricated Steel 3 Pole MCB 50 HZ 60 HZ 1500 1800
4.9 (1.3) 5.7 (1.5)
5.5 (1.5) 6.3 (1.7)
4 IN LINE 4 STROKE 84 (3.3) 100 (3.9) NATURALLY ASPIRATED WATER MECHANICAL ISO 8528
23.3:1
2.2 (135.2)
2.724 (9308) 12 Negative 65 242 (534) 251 (554)
Engine Performance Data 50 Hz 60 Hz
Engine Speed rpm Gross Engine Power Prime kW (hp) Gross Engine Power Standby kW (hp) BMEP Prime kPa (psi) BMEP Standby kPa (psi)
1500 1800
18.7 (25) 22 (30)
20.6 (28) 24.3 (33) 675 (97.9) 662 (96) 743 (107.8) 731 (106)