Pressure/vacuum switch
Type (V)PE-1/8-...(-SW), PE-PK-...(-SW)English
1Operating parts and connections
5
4
3
2
6
1 Compressed air or vacuum connection
– connecting thread G 1/8 with
(V)PE-1/8-...
– tubing connection with PE-PK-...
2 Screw terminals for electrical connection
3 Sub-base for mounting frame
Fig. 1
Festo (V)PE-...-...(SW) 2017-05c English
1
4 Through holes for fastening
5 Through holes for cover cap (type see
section 9 “Accessories”)
6 Cable for electrical connection
3
Page 4
(V)PE-...-...(SW )
Documentation on the product
For all available product documentation è www.festo.com/pk
2Product overview
Vacuum types
Vacuum
connection
Standard length for fitting
onto mounting fram
Electrical
connection
VPE-1/8G1/81NScrew terminals
VPE-1/8-SWG1/81NCables
VPE-1/8-2NG1/82NScrew terminals
VPE-1/8-2N-SWG1/82NCables
Fig. 2
Overpressure types
Compressed
air connection
PE-1/8-1NG1/81NScrew terminals
PE-1/8-2NG1/82NScrew terminals
PE-1/8-1N-SWG1/81NCables
Standard length for fitting
onto mounting frame
Electrical
connection
PE-1/8-2N-SWG1/82NCables
PE-PK-3x2-2NPK-32NScrew terminals
PE-PK-4-SWPK-41NCables
PE-PK-4PK-41NScrew terminals
Fig. 3
4
Festo (V)PE-...-...(SW) 2017-05c English
Page 5
(V)PE-...-...(SW )
3Function and application
The (V)PE-... contains a chamber with a dia
phragm.
This diaphragm is subjected to pressure
forces (with PE-...)/tensile forces (with
VPE-...) on one side, and to the clamping force
of the springs on the other side. If the pres
sure or vacuum forces are increased in excess
of the clamping force, a piston connected to
the diaphragm will move and actuate a
changeover switch.
The (V)PE-... can be used as a normally-closed, normally-open or changeover
switch. It has been designed for converting pneumatic pressure values into electri
cal signals which are used for control or monitor functions.
Fig. 4
4Conditions of use
Please note
Incorrect handling can lead to malfunctioning.
S Observe the following instructions for the correct and safe use of the prod
uct.
SCompare the specified limits, e.g. pres
sures, forces and temperatures with your
individual application.
SMake sure that there is a supply of cor
rectly prepared compressed air.
STake into account the prevailing ambient
conditions.
SObserve the technical regulations as well
as relevant national and local laws.
LF-...
40μm
Fig. 5
C
%
LR-...
mbar
Festo (V)PE-...-...(SW) 2017-05c English
Fig. 6
5
Page 6
(V)PE-...-...(SW )
SRemove all packing material such as protective wax, foils, caps and cartons.
The individual materials can be disposed of in separate containers for recycling
purposes.
SUse the product in its original state without undertaking any modifications.
5Fitting
Mechanical components
SSelect the suitable fastening method:
a) by means of through holes 4 in the
housing or
b) by fitting into the following mounting
frames:
– NRRQ-1N for (V)PE-...-1N, PE-PK-4
– NRRQ-2N for (V)PE-...-2N.
SFasten the (V)PE-... in the intended posi
tion.
Pneumatic components
SConnect the (V)PE-... to the compressed
air tubing using the following compo
nents:
(V)PE-
1/8PK-3-...PK-4-...
Screw connector
size G1/8
tubing
size 3
tubing
size 4
a)
4
b)
Fig. 7
1 Nm
Fig. 8
Maximum tighten
ing torque: 1 Nm
Fig. 9
6
——
Festo (V)PE-...-...(SW) 2017-05c English
Page 7
(V)PE-...-...(SW )
Electrical components
Using the (V)PE-... with screw terminals 2 and an operating voltage of ≥ AC/DC
50V:
Warning
You will receive an electric shock if you touch unprotected conductive compo
nents.
S Make sure that the electrical connections are protected in accordance with IP
SWire the (V)PE-... as follows:
20 (as per EN 60529). A protective cap as per Accessories (see section 9) is
required here.
Connection
PE-...VPE-...
Input
(common)
Normallyclosed
contact
Normallyopen
contact
Fig. 11
Input
(common)
Normallyopen
contact
Normallyclosed
contact
Screw ter
minal (see
Fig. 10)
1black
2grey
4blue
Cable
co
lours
(BK)
(GY)
(BU)
Fig. 10
Basic position PE-...Basic position VPE-...
Fig. 12
The wire surface area of the connecting cable must be between 0.34 mm2 and
2
1 mm
Festo (V)PE-...-...(SW) 2017-05c English
.
7
Page 8
(V)PE-...-...(SW )
Fastening the protective cap (type see section
9 “Accessories”)
SProceed as follows:
(A)
1. Insert the fastening pins into the
through holes 5.
2. Carefully press the protective cap
together until the hooks (A) and (B)
snap into place (do not break the
hooks off).
6Commissioning
SSwitch on the operating voltage.
SPressurize the compressed air connection with the pressure required as the
switching pressure, or evacuate the vacuum required as the switching vacuum.
SCheck the function by modifying the pressure or vacuum applied.
Voltage [V DC]:
– resistor load
– Induktive Last
– bulb load
POM/PA/St/VMQ
CR
PVC
Ag
15
10
10
3
PA/GD-AL/St/VMQ
TPE-U-(PU)
PVC
Ag
30
5
3
3
50
1
1
0,7
75
0,75
0,25
0,5
125
0,5
0,03
0,4
POM/PA/VMQ/St
CR
PVC
Ag
250
0,25
0,02
0,20
12
Festo (V)PE-...-...(SW) 2017-05c English
Page 13
(V)PE-...-...(SW )
Festo (V)PE-...-...(SW) 2017-05c
13
Page 14
Copyright:
Festo AG & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
Phone:
+49 711 347-0
Fax:
+49 711 347-2144
Reproduction, distribution or sale of this document or communica
tion of its contents to others without express authorization is
prohibited. Offenders will be liable for damages. All rights re
served in the event that a patent, utility model or design patent is
registered.
E-mail:
service_international@festo.com
Internet:
www.festo.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.