Festo VPE-1/8, VPE-1/8-2N, PE-1/8-1N, VPE-1/8-2N-SW, VPE-1/8-SW Operating Instructions Manual

...
Page 1
Pressure/vacuum switch (V)PE-1/8-...(-SW) PE-PK-...(-SW)
(en) Operating instructions
8068554 2017-05c [8068556]
Page 2
(V)PE-...-...(SW )
Original instructions
Symbols:
Fitting and commissioning to be carried out by qualified personnel only in accordance with the operating instructions.
Warning, Caution
Please note
Antipollution
Accessories
English 3 ....................................................................
2
Festo (V)PE-...-...(SW) 2017-05c
Page 3
(V)PE-...-...(SW )
Pressure/vacuum switch Type (V)PE-1/8-...(-SW), PE-PK-...(-SW)English
1 Operating parts and connections
5
4
3
2
6
1 Compressed air or vacuum connection
– connecting thread G 1/8 with
(V)PE-1/8-...
– tubing connection with PE-PK-...
2 Screw terminals for electrical connection
3 Sub-base for mounting frame
Fig. 1
Festo (V)PE-...-...(SW) 2017-05c English
1
4 Through holes for fastening
5 Through holes for cover cap (type see
section 9 “Accessories”)
6 Cable for electrical connection
3
Page 4
(V)PE-...-...(SW )
Documentation on the product
For all available product documentation è www.festo.com/pk
2 Product overview
Vacuum types
Vacuum connection
Standard length for fitting onto mounting fram
Electrical connection
VPE-1/8 G1/8 1N Screw terminals
VPE-1/8-SW G1/8 1N Cables
VPE-1/8-2N G1/8 2N Screw terminals
VPE-1/8-2N-SW G1/8 2N Cables
Fig. 2
Overpressure types
Compressed air connection
PE-1/8-1N G1/8 1N Screw terminals
PE-1/8-2N G1/8 2N Screw terminals
PE-1/8-1N-SW G1/8 1N Cables
Standard length for fitting onto mounting frame
Electrical connection
PE-1/8-2N-SW G1/8 2N Cables
PE-PK-3x2-2N PK-3 2N Screw terminals
PE-PK-4-SW PK-4 1N Cables
PE-PK-4 PK-4 1N Screw terminals
Fig. 3
4
Festo (V)PE-...-...(SW) 2017-05c English
Page 5
(V)PE-...-...(SW )
3 Function and application
The (V)PE-... contains a chamber with a dia phragm. This diaphragm is subjected to pressure forces (with PE-...)/tensile forces (with VPE-...) on one side, and to the clamping force of the springs on the other side. If the pres sure or vacuum forces are increased in excess of the clamping force, a piston connected to the diaphragm will move and actuate a changeover switch.
The (V)PE-... can be used as a normally-closed, normally-open or changeover switch. It has been designed for converting pneumatic pressure values into electri cal signals which are used for control or monitor functions.
Fig. 4
4 Conditions of use
Please note
Incorrect handling can lead to malfunctioning. S Observe the following instructions for the correct and safe use of the prod
uct.
S Compare the specified limits, e.g. pres
sures, forces and temperatures with your individual application.
S Make sure that there is a supply of cor
rectly prepared compressed air.
S Take into account the prevailing ambient
conditions.
S Observe the technical regulations as well
as relevant national and local laws.
LF-...
40μm
Fig. 5
C
%
LR-...
mbar
Festo (V)PE-...-...(SW) 2017-05c English
Fig. 6
5
Page 6
(V)PE-...-...(SW )
S Remove all packing material such as protective wax, foils, caps and cartons.
The individual materials can be disposed of in separate containers for recycling purposes.
S Use the product in its original state without undertaking any modifications.
5 Fitting
Mechanical components
S Select the suitable fastening method:
a) by means of through holes 4 in the
housing or
b) by fitting into the following mounting
frames:
NRRQ-1N for (V)PE-...-1N, PE-PK-4NRRQ-2N for (V)PE-...-2N.
S Fasten the (V)PE-... in the intended posi
tion.
Pneumatic components
S Connect the (V)PE-... to the compressed
air tubing using the following compo nents:
(V)PE-
1/8 PK-3-... PK-4-...
Screw connector size G1/8
tubing size 3
tubing size 4
a)
4
b)
Fig. 7
1 Nm
Fig. 8
Maximum tighten ing torque: 1 Nm
Fig. 9
6
Festo (V)PE-...-...(SW) 2017-05c English
Page 7
(V)PE-...-...(SW )
Electrical components
Using the (V)PE-... with screw terminals 2 and an operating voltage of ≥ AC/DC 50V:
Warning
You will receive an electric shock if you touch unprotected conductive compo nents.
S Make sure that the electrical connections are protected in accordance with IP
S Wire the (V)PE-... as follows:
20 (as per EN 60529). A protective cap as per Accessories (see section 9) is required here.
Connection
PE-... VPE-...
Input (common)
Normally­closed contact
Normally­open contact
Fig. 11
Input (common)
Normally­open contact
Normally­closed contact
Screw ter minal (see Fig. 10)
1 black
2 grey
4 blue
Cable co lours
(BK)
(GY)
(BU)
Fig. 10
Basic position PE-... Basic position VPE-...
Fig. 12
The wire surface area of the connecting cable must be between 0.34 mm2 and
2
1 mm
Festo (V)PE-...-...(SW) 2017-05c English
.
7
Page 8
(V)PE-...-...(SW )
Fastening the protective cap (type see section
9 “Accessories”)
S Proceed as follows:
(A)
1. Insert the fastening pins into the
through holes 5.
2. Carefully press the protective cap together until the hooks (A) and (B) snap into place (do not break the hooks off).
6 Commissioning
S Switch on the operating voltage.
S Pressurize the compressed air connection with the pressure required as the
switching pressure, or evacuate the vacuum required as the switching vacuum.
S Check the function by modifying the pressure or vacuum applied.
7 Care and maintenance
(B)
5
Fig. 13
Cleaning
S Switch off the operating voltage.
S If necessary, clean the (V)PE-....
Permitted cleaning agents are: – soap suds (max. +60 °C)
– all non-abrasive agents.
8
Festo (V)PE-...-...(SW) 2017-05c English
Page 9
(V)PE-...-...(SW )
8 Dismantling and repairs
Dismantling
S Switch off the following sources of power:
– the operating voltage – the compressed air – the vacuum.
Dismantling the protective cap (Type
section 9 “Accessories”)
S Proceed as follows:
1. Carefully press hook (A) outwards (do not break off).
2. Press hook (B).
3. Pull the protective cap apart.
S Disconnect the relevant connections from
the (V)PE-... .
9 Accessories
Designation Type
Protective cap (not necessary for (V)PE-...-SW) SPE-B
see
(B)
(A)
Fig. 14
Fastening bracket NRW-...
Barbed fitting N-...; CK-...; QSM-...
Mounting frame NRRQ-...
Fig. 15
Festo (V)PE-...-...(SW) 2017-05c English
9
Page 10
(V)PE-...-...(SW )
10 Eliminating faults
Fault Possible cause Remedy
(V)PE-... does not function Pressure failure Switch on compressed air
Connections not correct Connect (V)PE-... correctly
Short circuit at the switching out puts
Damage due to excess pressure/ vacuum
Incorrect operating voltage Apply correct operating voltage
(V)PE-... operated with non-per mitted medium
Outputs no longer switch back
Fig. 16
(V)PE-... defective Return (V)PE-... to Festo
11 Technical specifications
General specifications
Type
Eliminate short circuit
Replace (V)PE-...
Replace (V)PE and operate only with compressed air/vacuum
(V)PE-...
Design Diaphragm actuator
Mounting position As desired
Operating medium – with PE: filtered, non-lubricated or lubricated
Medium temperature Ambient temperature
Operating voltage range AC/DC 12 ... 250
Minimum load current [mA] 100
10
[°C] [°C]
compressed air, filter fineness 40 μm
– with VPE: vacuum
0 ... 60 0 ... 60
Festo (V)PE-...-...(SW) 2017-05c English
Page 11
(V)PE-...-...(SW )
Type (V)PE-...
Maximum switching frequency [Hz] 1
CE marking symbol (see conformity declaration) as per EU low voltage directive
Fig. 17
Product-specific specifications (V)PE-... without (V)PE-....-SW
Typ
Part no. 7470 13691 6217 7860 12592 12594
Operating pressure [bar] 0 ... 0,25 0 ... 8 0 ... -0,95
Switch-on point [bar] ≤ 0,08 ≤ 2 -0,25 0,05
Switch-off point [bar] ≥ 0,01 ≥ 0,5 ≤ -0,1
Overload pressure (brief, static)
Rated operating voltage (Vb)
Rated operating cur rent (with Vb) [A]
Use category – ohmic load
[bar] max. 8 max. 12 max. 1
[V] AC/DC 250
[A]
PE-PK-4 PE-PK-
3x2-2N
– ohmic load – inductive load
– small electromagnetic load
PE­1/8-1N
at AC 250 V 6 2
PE­1/8-2N
AC 12/DC 12 AC 14/DC 13
VPE­1/8
at DC 250 V 0,25 0,1
VPE­1/8-2N
Switching output (DC voltage) [A]
[A] [A]
Protection class (as per EN 60 529) IP00, IP20 with protective cap type SPE-B
Materials – Housing – Connections – Diaphragm – Switching contact
Fig. 18
Festo (V)PE-...-...(SW) 2017-05c English
Voltage [V DC]: – resistor load – inductive load – bulb load
PET/POM/St CuZn CR Ag
12 6 6 3
PA/GD-AL/St/PET CuZn TPE-U(PU) Ag
24 6 6 2
60 1 0,5 0,6
110 0,5 0,2 0,5
PET/POM/St CuZn CR Ag
220 0,25 0,1 0,25
11
Page 12
(V)PE-...-...(SW )
Product-specific specifications (V)PE-...-SW (cable types)
Typ
Part no. 7471 6484 7862 12593 12595
Operating pressure [bar] 0 ... 0,25 0 ... 8 0 ... -0,95
Switch-on point [bar] ≤ 0,25 ≤ 2 -0,25 0,05
Switch-off point [bar] ≥ 0,07 ≥ 0,5 ≤ -0,1
Overload pressure (brief, static)
Rated operating voltage (Vb)
Rated operating cur rent (with Vb) [A]
Use category – ohmic load
[bar] max. 8 max. 1
[V] AC/DC 250
[A]
PE-PK-4-SW PE-1/8-
1N-SW
bei AC 250 V – ohmic load – induktive Last
– small electromagnetic load
5
2
PE-1/8­2N-SW
VPE­1/8-SW
bei DC 250 V 0,25 0,03
AC 12/DC 12 AC 14/DC 13
VPE-1/8­2N-SW
Switching output (DC voltage) [A]
[A] [A]
Protection class (as per EN 60 529) IP67
Materials – Housing – Connections – Diaphragm – Switching contact
Fig. 19
Voltage [V DC]: – resistor load – Induktive Last – bulb load
POM/PA/St/VMQ CR PVC Ag
15
10
10
3
PA/GD-AL/St/VMQ
TPE-U-(PU)
PVC
Ag
30 5 3 3
50 1 1 0,7
75 0,75 0,25 0,5
125 0,5 0,03 0,4
POM/PA/VMQ/St CR PVC Ag
250 0,25 0,02 0,20
12
Festo (V)PE-...-...(SW) 2017-05c English
Page 13
(V)PE-...-...(SW )
Festo (V)PE-...-...(SW) 2017-05c
13
Page 14
Copyright: Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany
Phone: +49 711 347-0
Fax: +49 711 347-2144
Reproduction, distribution or sale of this document or communica tion of its contents to others without express authorization is prohibited. Offenders will be liable for damages. All rights re served in the event that a patent, utility model or design patent is registered.
E-mail: service_international@festo.com
Internet: www.festo.com
Loading...