Festo VACC-S13-11-K4-1-EX4A Original Instructions Manual

Solenoid Coil VACC-S13-11-K4-1-EX4A
II 2G Ex ia IIC T6, T5 Gb II 2D Ex ia IIIC T80°C, T95°C IP64 Db
Festo AG & Co. KG
Ruiter Straße 82 73734 Esslingen Deutschland +49 711 347-0 www.festo.com
Operating conditions EX (Original instructions)
8070989 1702c [8070991]
Solenoid coil VACC-S13-11-K4-1-EX4A English............................
All available documents for the product è www.festo.com/pk
Note
Technical data for the product can have different values in other documents. During operation in an explosive atmosphere, the technical data of this document always has priority.
1 Certified solenoid coils
Voltage Type Part no.
14 … 32 V DC VACC-S13-11-K4-1-EX4A 562896
Fig. 1
2 Function
When switching on the voltage, the solenoid is energised and the valve is actuated. A built-in current pulse generator permits operation on low-power electric networks.
3 Application
 The solenoid coil is intended to be used to actuate Festo valves.  Operate the solenoid valve with compressed air only.  The device is not intended to be used with other fluids.  The solenoid coils can be used in combination with the specified solenoid valves
in zones 1 and 2 for potentially explosive gas atmospheres and in zones 21 and22 for potentially explosive dust atmospheres.
Note
Label X: special conditions  Only use specified solenoid valves.  The range of application is dependent on the ambient temperature.  The device must be connected to a certified Ex ia IIC or Ex ib IIC power circuit.  Protect the housing from mechanical impact > 4 years.  Protect the device from electrostatic discharge.  Protect the filling compound from mechanical impact energy.
4 Transport and storage
 Observe the following storage conditions: short storage times in cool, dry,
shaded and corrosion-resistant locations.
5 Requirements for product use
 Comply with all applicable national and international regulations.
Note
Installation and commissioning should only be carried out by qualified electrical specialists.
6 Mounting
7
6
1
2
3
8
5
4
1 Port 12 (only for external pilot air
supply)
2 Ribbed disc 3 Vent screw/retaining nut 4 Cable fitting
(with cap nut)
5 Cover, terminal housing
6 Solenoid coil 7 Armature guide tube 8 Solenoid valve
Fig. 1
6.1 Mechanical
1. Tighten vent screw. Twisting the solenoid coil is no longer possible (tightening torque 4…6 Nm).
2. Open cover of terminal housing.
3. Connect electrical cables to the terminals. Observe polarity (tightening torque2…3 Nm).
4. Close the cover of the terminal housing (tightening torque: 0.6…0.7 Nm).
5. With external pilot air supply, use connection 12.
6. Seal unused openings with blanking plugs or slot covers.
Note
The surface coating of the solenoid valves is electrically non-conductive.  Include the device in the system’s potential equalisation.
6.2 Pneumatic
1. Mount connecting cables and fittings properly. Before commissioning, remove residue, such as chips, rust and water.
2. Depressurise the compressed air lines.
3. Use only fittings with cylindrical threaded lugs and sealing rings or cutting rings.
4. Do not use PTFE or hemp fibres on the threads.
5. Insert all sealing rings supplied with the NAMUR mounting kit between solenoid valve and drive or mounting plate.
6. If port 1 with control signal < 2 bar, then supply auxiliary energy > 2 bar to port 12.
7. Do not use anti-friction coating or lubricant.
8. The dew point of the compressed air must lie below the specified lowest operat ing temperature of the system.
9. Use filter adapter NPFV-AF-G14-G14-MF or NPFV-AF-G14-N14-MF.
10.Use exhaust protection VABD-D3-SN-G14.
6.3 Electrical system
1. Only use an unsheathed cable with an external diameter of 7 … 13 mm for the installed cable fitting M20 x 1.5.
2. Any polarity is acceptable.
3. To avoid the ingress of water, tighten fitting and locking ring with a spanner until sufficient sealing force has been attained.
4. Use cable strain relief.
Electrical connection diagram
VACC-S13-11-K4-1-EX4A
Fig. 2
Block circuit diagram
II (2) G [Ex ib Gb] IIC II (2) D [Ex ib Db] IIIC
+
DC
I
7 Commissioning
 Observe the specifications on the product labelling.  Do not commission the solenoid coil until after mounting.
Warning
The discharge of electrostatically charged parts can lead to ignitable sparks.  Prevent electrostatic discharge by taking appropriate installation and cleaning
measures.
 Include the device in the system’s potential equalisation. The surface coating
of the solenoid valves is electrically non-conductive.
 Prevent processes that are charge generating.
Note
Escaping exhaust air can swirl up dust and create an explosive dust atmosphere.
Note
Dimension the intrinsically safe circuit, taking account of the permissible elec trical limit values è Technical data
Note
For sheathed cables, observe the following:  Cut off the outer jacket of the cable and the sheathing at the same level.  Connect the sheathing at the other end to the potential equalisation.
8 Operation
 Observe the operating conditions.  Comply with permissible limit values è Technical data.  Draw in operating medium outside potentially explosive areas.
9 Dismounting
1. Switch off the power supply.
2. Open the cover of the terminal housing.
3. Disconnect electrical cables from terminals.
4. Close cover of terminal housing.
5. Loosen the retaining nut. Remove solenoid coil.
Note
When loosening the cap nut, prevent the cable connector from working loose.
10 Maintenance and care
Note
The discharge of electrostatically charged parts can lead to ignitable sparks. Ifused in group IIC:  Only clean the device with a damp cloth.
 Changes or repairs to the solenoid coil are not permitted.  The device is maintenance-free.
11 Certifications
Region/country
Certificate no.
Europe BVS 15 ATEX E 030 X Brazil TÜV 12.1949 China GYJ111105
Fig. 2
12 Technical data
Operating conditions
Power supply only from certified intrinsically safe circuits Ex ia IIC or ib IIC Electrical limit values
Max. input voltage U
i
V 32
Max. input current I
i
mA 200
Max. power P
i
W 1.2
Effective inner inductance L
i
H L 0
Effective inner capacitance C
i
nF L 0
Resistance R
20
Ω 865
Nominal voltage U
N
V DC 14 … 32
Nominal current I
N
mA 16 … 35
Nominal power P
N
mW 220 … 1100 Pulling current mA 15 Holding current mA 4 Drop-off current mA 2
Duty cycle 100 % (continuous operation) Degree of protection IP64 in accordance with EN60529 Overvoltage category III in accordance with EN 60664-1 Connecting cable
Conductor cross-section mm20.75 … 1.5 Cable diameter mm 7 … 13 Cable entry thread M20 x 1.5
Temperature class at surface temperature T
a
–30 ≤ Ta ≤ +50 °C T6, T80°C –30 ≤ Ta ≤ +65 °C T5, T95 °C
Storage temperature °C –30 … +80 Relative humidity 95 % (non-condensing) Mounting Individual mounting Mounting position Any
Sealing compound points to the valve body
Materials
Housing Polyamide 6 Sealing compound Polyurethane
Fig. 3