Symbols:
Fitting and commissioning to be carried out
by qualified personnel only in accordance
with the operating instructions.
Warning, Caution
Please note
Antipollution
Accessories
English 3 ....................................................................
2
Festo (V)PE-...-...(SW) 2017-05c

(V)PE-...-...(SW )
Pressure/vacuum switch
Type (V)PE-1/8-...(-SW), PE-PK-...(-SW)English
1 Operating parts and connections
5
4
3
2
6
1 Compressed air or vacuum connection
– connecting thread G 1/8 with
(V)PE-1/8-...
– tubing connection with PE-PK-...
2 Screw terminals for electrical connection
3 Sub-base for mounting frame
Fig. 1
Festo (V)PE-...-...(SW) 2017-05c English
1
4 Through holes for fastening
5 Through holes for cover cap (type see
section 9 “Accessories”)
6 Cable for electrical connection
3

(V)PE-...-...(SW )
Documentation on the product
For all available product documentation è www.festo.com/pk
2 Product overview
Vacuum types
Vacuum
connection
Standard length for fitting
onto mounting fram
Electrical
connection
VPE-1/8 G1/8 1N Screw terminals
VPE-1/8-SW G1/8 1N Cables
VPE-1/8-2N G1/8 2N Screw terminals
VPE-1/8-2N-SW G1/8 2N Cables
Fig. 2
Overpressure types
Compressed
air connection
PE-1/8-1N G1/8 1N Screw terminals
PE-1/8-2N G1/8 2N Screw terminals
PE-1/8-1N-SW G1/8 1N Cables
Standard length for fitting
onto mounting frame
Electrical
connection
PE-1/8-2N-SW G1/8 2N Cables
PE-PK-3x2-2N PK-3 2N Screw terminals
PE-PK-4-SW PK-4 1N Cables
PE-PK-4 PK-4 1N Screw terminals
Fig. 3
4
Festo (V)PE-...-...(SW) 2017-05c English

(V)PE-...-...(SW )
3 Function and application
The (V)PE-... contains a chamber with a dia
phragm.
This diaphragm is subjected to pressure
forces (with PE-...)/tensile forces (with
VPE-...) on one side, and to the clamping force
of the springs on the other side. If the pres
sure or vacuum forces are increased in excess
of the clamping force, a piston connected to
the diaphragm will move and actuate a
changeover switch.
The (V)PE-... can be used as a normally-closed, normally-open or changeover
switch. It has been designed for converting pneumatic pressure values into electri
cal signals which are used for control or monitor functions.
Fig. 4
4 Conditions of use
Please note
Incorrect handling can lead to malfunctioning.
S Observe the following instructions for the correct and safe use of the prod
uct.
S Compare the specified limits, e.g. pres
sures, forces and temperatures with your
individual application.
S Make sure that there is a supply of cor
rectly prepared compressed air.
S Take into account the prevailing ambient
conditions.
S Observe the technical regulations as well
as relevant national and local laws.
LF-...
40μm
Fig. 5
C
%
LR-...
mbar
Festo (V)PE-...-...(SW) 2017-05c English
Fig. 6