Festo PDAD Series, PDAD-13, PDAD-09, PDAD-22, PDAD-51 Operating Instructions Manual

...
(en) Operating instructions
8068814 1701g [8068816]
Adsorption dryer
PDAD
2 | Festo PDAD 1701g
Original instructions
Installation and commissioning are to be carried out only by qualified personnel in accordance with the operating instructions.
Festo PDAD 1701g English | 3
Table of contents
1. Introduction .................................................................................................................. 4
2. Safety ............................................................................................................................ 5
3. Component designation ................................................................................................ 7
3.1 Overview ....................................................................................................................... 7
3.2 Electronic controller 2 ................................................................................................ 9
3.3 Multiple distributor aJ ................................................................................................ 9
3.4 Desiccant cartridge with integrated dust filter 9 ........................................................ 9
3.5 Reservoir 7 ................................................................................................................. 9
4. Function ...................................................................................................................... 10
5. Installation .................................................................................................................. 11
5.1 Mounting the micro filter on the dryer ........................................................................ 11
5.2 Pneumatic connection ................................................................................................. 13
5.3 Assembling the mounting accessories on the dryer ....................................................14
5.4 Changing the connections for the inlet and outlet ...................................................... 15
5.5 Installation conditions ................................................................................................ 16
6. Power supply ..............................................................................................................17
6.1 Voltage connection .....................................................................................................17
6.2 Power supply socket connection .................................................................................18
6.3 Alarm connection ........................................................................................................ 19
7. Commissioning ........................................................................................................... 20
8. Maintenance and care ................................................................................................. 22
8.1 LED displays ................................................................................................................ 22
8.2 Decommissioning for maintenance purposes ............................................................. 24
8.3 Maintenance and service ............................................................................................ 24
8.4 Removing/installing the front or rear cover ................................................................ 25
8.5 Replacing or cleaning the air nozzle ............................................................................26
8.6 Cleaning the silencer ................................................................................................... 27
8.7 Resetting the controller ..............................................................................................28
9. Troubleshooting .......................................................................................................... 29
9.1 General fault finding ................................................................................................... 29
9.2 Electrical troubleshooting ........................................................................................... 30
10. Accessories ................................................................................................................. 31
11. Technical data ............................................................................................................. 32
4 | Festo PDAD 1701g English
1. Introduction
For all available product documentation www.festo.com/pk
The product described in these operating instructions may only be installed, operated and maintained if these operating instructions have been completely read and understood by the employees handling the product.
These operating instructions and in particular the safety instructions are to be kept with the product or as a print-out or copy. The operating instructions must be strictly adhered to.
Please keep the following information available if you need to contact Festo with regard to the product or the operating instructions.
• Part number and type designation
• Date commissioned
The part number and type designation can be found on the rating plate on the top right­hand side of the device. Please note this information in the operating instructions as a reminder and for future use.
The dryer is delivered in protective packaging. Use due diligence when transporting, loading and unloading the device.
On delivery, the dryer is configured with an air nozzle for an operating pressure of 7 to 9 bar. You must ensure that the correct air nozzle is attached for the anticipated operating pressure. For more information see the table with technical data in chapter 11.
Scope of delivery
Adsorption dryer PDAD
Micro filter MS6-LFM
Adapter kit Power supply
socket
Tubing Operating
instructions PDAD
Festo PDAD 1701g English | 5
2. Safety
Festo expressly excludes any liability or responsibility for damages and/or injuries which result from violation of these operating instructions.
The device may only be used for its intended purpose. The cold regenerative adsorption dryer is only to be used according to its intended purpose for drying pressurised air under the conditions described in chapter 11 of these operating instructions. Any other use of the device is considered not for its intended purpose. Festo is not liable for damages which result from misuse.
The following symbols indicate a possible hazard. Where such hazards arise, the appropriate measures must be taken in order to reduce the risk for the user or operator of the product.
Caution:
Source of danger
Attention:
Danger due to
electrical voltage
Attention:
Danger due to high
pressures
Note on Pressure Equipment Directive
Classification of the dryers in pressure equipment categories
Category
Type
I
PDAD-09IPDAD-13IPDAD-22IPDAD-51IIPDAD-73IIPDAD-100
Notes on commissioning and maintenance
Vibrations can cause fatigue in the material and can decrease the endurance limit of the adsorption dryers and mounting components.
• Protect adsorption dryers and mounting components against mechanical vibrations.
Commissioning and the intervals for periodic inspections are subject to the applicable national regulations.
When carrying out maintenance work, inspect components visually for damage. Replace the device if necessary.
6 | Festo PDAD 1701g English
The following safety regulations need to be strictly adhered to:
• These operating instructions or a print-out or copy thereof are to be left at the place where the product is installed.
• Repair work on the device is only to be carried out by personnel authorised by Festo.
• Operating, repair and maintenance personnel must be aware of the following information:
– Accident prevention regulations
– Safety information (general and device specific)
– Device safety equipment
– Measures to be taken in an emergency
• It is the installer's responsibility to ensure that the cables to and from the dryer are suitable for the task, correspond to the applicable laws and have been subjected to a visual check and tests before commissioning. All cables must be fitted in an appropriate manner.
• The device must be decommissioned before carrying out any maintenance or repair work. Operators and other personnel are exposed to a risk if work is carried out on a running device. Decommissioning the device means disconnecting it from the power supply and compressed air supply, and ensuring the pressure is completely reduced.
• Only trained specialists who are aware of the electrical requirements of the device as described in these operating instructions as well as the safety regulations and conditions are permitted to carry out work on the electrical components and the power supply of the device.
• Use suitable, correctly sized tools that are in good condition to carry out any work on the device.
• Only use accessories and spare parts from the manufacturer. There is no guarantee that non-original spare parts are designed and manufactured to correspond to the safety and operating requirements of the device. Festo takes no liability for device faults which result from the use of unapproved spare parts.
• Use suitable and safe work platforms or other secure work access options to carry out installation work above head height.
• Do not make any design changes to the product. Changes and modifications may only be carried out by Festo.
• All faults or defects which could impair safety must be eliminated before using the device.
• Used objects and materials must be correctly disposed of in line with the local laws and conditions. This applies in particular to the desiccant cartridges.
Festo PDAD 1701g English | 7
3. Component designation
On the back of the dryer
ad
1 Upper valve block 2 Electronic controller 3 Lower valve block 4 Floor plate 5 Front cover 6 Mounting screw front cover 7 Reservoir 8 Mounting screw reservoir 9 Desiccant cartridge with integrated
dust filter
aJ Multiple distributor aA Cover plate aB Cover plate mounting screw aC Rear cover aD Power supply socket aE Reservoir seal screw aF Seal aG Silencer aH Air nozzle
aB aHaJ aA
1
aC
8
7
9
3
aG
5
6
2
aF
4
aE
3.1 Overview
The figure below shows the main components of the dryer PDAD-09/13/22/51/73 .
8 | Festo PDAD 1701g English
On the inside of the dryer
ad
1 Upper valve block 2 Electronic controller 3 Lower valve block 4 Floor plate 5 Front cover 6 Mounting screw front cover 7 Reservoir 8 Mounting screw reservoir 9 Desiccant cartridge with integrated
dust filter
aJ Multiple distributor aA Cover plate
aB Cover plate mounting screw aC Rear cover with cable throughfeed for
mains connection
aD Power supply socket aE Reservoir seal screw aF Seal aG Silencer aH Air nozzle aI Multiple distributor connection
screws
bJ Seal for connecting multiple
distributor
The figure below shows the main components of the dryer PDAD-100.
aB aH
aJ
aA
aI
1
aC
8
7
9
3
5
6
4
2
aG
aF
aE bJ
Festo PDAD 1701g English | 9
3.2 Electronic controller 2
The valve blocks (on top and below) are actuated by solenoid valves in the controller which determine the pressure and direction of the air flow in the desiccant cartridge.
3.3 Multiple distributor aJ
The standard design of the dryer is configured in such a way that the inlet openings are on the left and the outlet openings on the right when looking at the front of the device. By using the opening nozzles several different opening requirements become available. See also section 5.4.
Inlet
See the direction of the arrows for inlet side of the dryer
Outlet
Installation in corners
3.4 Desiccant cartridge with integrated dust filter 9
The desiccant cartridges contain a drying agent which has been developed for drying compressed air. The drying agent is contained in a transparent tube with end pieces which allow the air to flow through at both ends. In the upper part of each cartridge is a 1 micron filter to separate residual dust from the drying agent. The cartridge length varies with the rated output of the dryer.
3.5 Reservoir 7
The desiccant cartridge is located in an extruded aluminium reservoir and has pressurised end caps. The operating pressure and the flow through the individual cartridges is controlled by the valve blocks positioned between the two reservoirs. The regenerative air flow (purge air flow) is controlled by an external air nozzle with a small opening (front, central) on the upper valve block, accessible by removing the cover.
10 | Festo PDAD 1701g English
4. Function
During dry operation an even, uninterrupted supply of compressed air should be provided according to the specification.
This function is achieved with two compressed air reservoirs which operate in alternating cycles. If air is being dried in one reservoir, the drying agent in the second reservoir can regenerate.
In the adsorption dryer the main air flow is fed through the desiccant cartridge(s) of a reservoir. This removes the moisture so the required pressure dew point can be achieved. A small amount of the dry air (purge air) is fed to the other reservoir. The purge air flows through the desiccant cartridge(s), escapes into the atmosphere through a drain valve and thus regenerates the drying agent.
The regeneration cycle lasts 120 seconds. The corresponding drain valve is then closed. This means the regenerated reservoir can be brought up to system pressure with the purge air and can switch to the operating cycle. After a further 50 seconds the other reservoir starts a new regenerative operating cycle.
Festo PDAD 1701g English | 11
In order to protect the drying agent from contaminated pressurised air the micro filter MS6-LFM supplied must be mounted on the inlet of the dryer. On delivery, the three inlet options are on the left-hand side of the dryer (see arrow). If an inlet on the right-hand side is required the multiple distributor in the cover of the dryer must be turned (see chapter 5.4).
1. Select an inlet opening.
Remove any sealing plugs and attach them to the unused inlet.
2. Insert a lightly greased O-ring 2 in
the slot of inlet 1.
3. Fit the module connecting plate 3
with hollow bolt 4 with spanner size 10 (for PDAD-...y) or max. 14 Nm (for PDAD-...½). The maximum tightening torque is 15 Nm (for PDAD-...y) or max 18 Nm (for PDAD-...½). The module connecting plate 3 can be adjusted 90° for horizontal instal­lation of the dryer.
5. Installation
5.1 Mounting the micro filter on the dryer
1
2
3
3
4
Loading...