Festo MPA-L Series, MPA-L-MPM-VI, MPA-L-FB-VI Description

MPA−L valve terminal
Description Pneumatic MPA−L
Valve terminal
Type: MPA−L−MPM−VI MPA−L−FB−VI
Description
556 354 en 1008NH [722 279]
Contents and general safety instructions
Original de. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Edition en 1008NH. . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
Designation P.BE−MPAL−EN. . . . . . . . . . . . . . . . . . . . . . . . . .
OrderNo. 556
354. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
E (Festo AG&Co. KG, D73726 Esslingen, Federal Republic of Germany, 2010) Internet:http://www.festo.com E−Mail: service_international@festo.com
The copying, distribution and utilization of
this document as well as the communication of its contents to others without express authorization is prohibited. Offenders will be held liable for the payment of damages. All rights are reserved, in particular the right to carry out patent, registered design or ornamental design registration.
Festo P.BE−MPAL−EN en 1008NH
I
Contents and general safety instructions
®
TÜV
is a registered trade mark of the respective trademark owner. . . . . . . . . . . . . . . . .
in certain countries.
VDE
®
is a registered trade mark of the respective trademark owner. . . . . . . . . . . . . . . . .
in certain countries.
Torx
®
is a registered trade mark of the respective manufacturer in. . . . . . . . . . . . . . . . .
certain countries.
II
Festo P.BE−MPAL−EN en 1008NH
Contents and general safety instructions

Contents

Intended use VII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Areas of application and approval by authorities VII . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Target group VIII . . .
Service VIII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Structure of this manual VIII . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important user instructions IX . . . . . . . . . . . . . . . . . . . . . . . . . . .
Terms and abbreviations XI . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
1. Overview of components 1−1 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1 The valve terminal MPA−L 1−3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2 Valve terminal design 1−4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3 Electrical multi−pin connection 1−5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3.1 Versions of the connector 1−6 . . . .
1.3.2 Versions of the IP protection class 1−7 . . . . . . . . . . . . . . . .
1.4 Electrical connection via CPX terminal 1−8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.5 Description of components 1−9 . .
1.5.1 Valves 1−9 . . . . . . . . . . . . .
1.5.2 Main and additional power supply 1−10 . . . . . . . . .
1.5.3 Pilot air supply 1−11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.5.4 Exhaust air 1−13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.5.5 Sub−bases and pressure zone separation 1−13 . . . . . . . . . . . . . . . . . . . .
1.5.6 Vertical stacking 1−15 . . . . . . . . . . . . . . . .
1.5.7 Pressure regulating plates 1−16 . . . . . . . . . . . . . . . . . . . . . . .
1.6 Connecting elements 1−20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.7 Display and control elements 1−22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.7.1 Identification system" (as per catalogue) 1−23
1.7.2 Manual override (MO) 1−23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.7.3 Pressure regulator 1−24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.7.4 Switching status
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
displays for valves 1−25 . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . .
. . .
. . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . .
. . . . . . . . .
. . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . .
2. Mounting 2−1 . . . . . . . . . . . . . . . . . . . . . .
2.1 General instructions on mounting/dismantling 2−3 . . . . . . . . . . . . . . .
Festo P.BE−MPAL−EN en 1008NH
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . .
III
Contents and general safety instructions
2.2 Installation/removal on an H−rails 2−4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3 Wall installation/removal 2−9 . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3.1 Standard mounting points of the valve terminal 2−9 . . . . . . . . . . . . .
2.3.2 Additional mountings of the valve terminal 2−11 . . . . . . . . . . . . . . . . . . .
2.4 Fitting/removing optional inscription label holders 2−13 . . . . . . . . . . . . . . . . . . .
. .
.
3. Installation 3−1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . .
3.1 Compressed air preparation 3−3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1.1 Operation with unlubricated compressed air 3−3 . .
. . . . . . . . . . . . . . .
3.1.2 Operation with lubricated compressed air 3−3 . . . . . . . . . . . . . . . . . . . .
3.2 General instructions on installation 3−6 . . . . . .
3.3 Connecting the valve terminal MPA−L 3−7 . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . .
3.3.1 Pilot control of the solenoid coils (pilot air supply) 3−7 . . . . . . . . . . . . .
3.3.2 Valve terminal MPA−L with pressure zone separation 3−8 . . . . . . . . . .
3.3.3 Setting the pressure regulating valve 3−10 . . . . . . . . . . . . . . . . . . . . . . .
3.3.4 Vacuum/low pressure operation 3−11 . . . . . . . . . . . . . . . . . . .
. . . . . . . .
3.4 Connecting the pneumatic lines 3−13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.1 Installation/replacement of the
3.4.2 Laying the tubing 3−18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
threadless car tridges 3−15 . . . . . . . . . .
. . . .
3.4.3 Common pneumatic lines 3−20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5 Connecting the electric cables 3−21 . . . . . .
3.6 Address assignment of the valves 3−24 . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
3.6.1 Valve terminal MPA−L with multi−pin plug connection 3−28 . . . . . . . . . . .
3.6.2 Valve terminal MPA−L with CPX terminal 3−28 . . . . . . .
4. Commissioning 4−1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1 General Information 4−3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . .
4.1.1 Prior to commissioning 4−3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1.2 Pressure build−up in the
overall supply 4−3 . . . . . . . . . . . . . . . . . . . . . .
4.2 Checking the valves and the valve/actuator combination 4−6 . . . . . . . . . . . . . . .
4.3 Mounting/removing the optional manual
override cover cap 4−11 . . . . . . . . . . . .
.
IV
Festo P.BE−MPAL−EN en 1008NH
Contents and general safety instructions
4.4 Troubleshooting 4−13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.4.1 Switching status
4.4.2 Impairment of functions 4−13 . . . . . . . . . . . . . . . . . . . . . . . . . . .
indicator of the solenoid coils 4−13 . . . . . . . . . . . . . . .
. . . . . . .
4.4.3 Operating states of the pneumatic system 4−15 . . . . . . . . . . . . . . . . . . .
5. Conversion and maintenance 5−1 . . . . . . . . . . . . . . . .
5.1 General preventive action 5−3 . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . .
5.2 Maintaining the valve terminal MPA−L 5−4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2.1 Clean
5.2.2 Replacing valves or cover plates 5−5 . . . . . . . . . . . . . .
or replace flat plate silencer 5−4 . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . .
5.3 Conversion of the MPA−L valve terminal 5−7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.1 Tie rod system 5−7
5.3.2 Exchange sub−base, supply plate or extend or exchange
right−hand end plate 5−11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3.3 Replace the electronic module 5−14 . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
5.3.4 Conversion between ducted and unducted exhaust air 5−15 . . . . . . . . .
5.3.5 Conversion between internal and external pilot air supply 5−16 . . . .
. . .
5.3.6 Converting the valve terminal MPA−L to different pressure zones 5−18 .
5.3.7 Conversion of the left−hand end plate of IP40 on IP65 cover 5−19 . . . . .
5.3.8 Conversion of the outlet direction of the multi−pin cable 5−19 . . . . . . . .
5.3.9 Conversion of the end plate
between multi−pin and
CPX connection 5−22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.4 Replace the pneumatic interface 5−24
A. Technical appendix A−1 . . . . . . . . . . . . . .
A.1 Technical data A−3 . . . . . . . . . . . . . . . . .
A.2 Festo accessories A−12 . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B. Supplementary overview of components B−1 . . . . . . . . . . . . . . .
. . . . . . . . . . . .
B.1 Overview of valve position components B−3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C. Index C−1 . . . .
Festo P.BE−MPAL−EN en 1008NH
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V
Contents and general safety instructions
VI
Festo P.BE−MPAL−EN en 1008NH
Contents and general safety instructions

Intended use

The MPA valve terminals are intended for fitting into a machine or automated system and must be used exclusively as follows:
In industrial applications
In original status without unauthorised modifications.
Only the conversions or modifications described in the documentation supplied with the product are permitted.
In perfect technical condition
If used together with additional ponents, such as actuators, the specified limits for pressures, temperatures, electrical data, torques etc. must be observed.
In addition to the safety instructions in this manual always observe the regulations of the trade associations and the German Technical Control Board (TÜV) and the VDE condi tions or corresponding national conditions on−site.

Areas of application and approval by authorities

The product fulfils the requirements of the EU directives and is marked with the CE marking symbol.
Standards and test values, which the product must comply with and fulfil, can be found in the section A.1 Technical data". The product−relevant EC directive can be found in the declaration of conformity.
commercially available com
Festo P.BE−MPAL−EN en 1008NH
VII
Contents and general safety instructions

Target group

This manual is intended exclusively for technicians trained in control and automation technology.

Service

Please consult your local Festo repair service if you have any technical problems.

Structure of this manual

This manual contains general basic information on fitting, installing and commissioning the valve terminal MPA−L, as well as on its mode of operation.
VIII
Festo P.BE−MPAL−EN en 1008NH
Contents and general safety instructions

Important user instructions

Danger categories
This description contains instructions on the possible dangers which can arise if the product is not used correctly. These instructions are marked (Warning, Caution, etc.), printed on a shaded background and marked additionally with a picto gram. A distinction is made between the following danger warnings:
Warning
... means that failure to observe this instruction may result in serious personal injury or material damage.
Caution
... means that failure to observe this instruction may result in personal injury or material damage.
Festo P.BE−MPAL−EN en 1008NH
Note
... means that failure to observe this instruction may result in material damage.
Additio na l ly, the following pictogram designates text passages, which describe activities with electrostatically sensitive devices:
Electrostatically sensitive devices: inappropriat e handling can result in damage to components.
IX
Contents and general safety instructions
Identification of special information
The following pictograms designate text passages that contain special information.
Pictograms
Information: Recommendations, tips and references to other sources of information.
Accessories: Information on necessary or useful accessories for the Festo product.
Environment: Information on environmentally friendly use of Festo products.
Text designations
· Bullet points indicate activities that may be carried out
in any sequence.
1. Numerals indicate activities that must be carried out in the sequence specified.
Arrowheads indicate general listings.
X
Festo P.BE−MPAL−EN en 1008N H
Contents and general safety instructions

Terms and abbreviations

The following product−specific terms and abbreviations are used in this manual:
Term/abbreviation
Blanking plate Plate without valve function for sealing vacant valve positions on
Cartridge fitting Plug connector for connection of the power supply cables to the valve
Components Common term for pneumatic interface, multipin sub−base, exhaust
Electronics module Module in the sub−base with an LED and solenoid coil management
End plate Extreme right−hand plate with/without connections for power and
Exhaust plate Plate for ducted exhaust with connection 3/5
MO Manual override
MPA1 Sizes of the solenoid valves: MPA1 = 10 mm wide
Multi−pin plug connection Electrical connection for controlling the valve terminal MPA−L
Pneumatic interface The pneumatic interface is the interface between the modular
Pneumatic module Module consisting of pneumatic Sub−base, electronics module,
Meaning
sub−bases (vacant position).
terminal
plate, silencer, pneumatic sub−base or pneumatic supply plate, end plate, pressure regulator plate, solenoid valve and cover plate
pilot pressure and exhaust air, and extreme left−hand plate with multi− pin plug connection and CPX terminal as well as holes for H−rail and wall mountings.
electrical peripherals of the CPX terminal and the MPA−L pneumatics
solenoid valves or cover plates
Solenoid valves Monostable solenoid valve with a solenoid coil, double−solenoid or
mid−position valves with two solenoid coils and additional variants
Sub−base Plate with working lines 2 and 4 for the mounting of valves and verti
cal stackings
Supply plate Plate for (additional) supply of compressed air to the solenoid valves,
e.g. with several pressure zones.
Festo P.BE−MPAL−EN en 1008NH
XI
Contents and general safety instructions
Term/abbreviation Meaning
Valve terminal MPA−L Modular performance valve manifolds light valve terminal (Type 34)
Vertical stacking Pneumatic components that are installed between the sub−base and
multi−pin plug connection or for CPX−Terminal
the solenoid valve
Tab.0/1: Product−specific terms and abbreviations
XII
Festo P.BE−MPAL−EN en 1008NH

Overview of components

Chapter 1
1−1Festo P.BE−MPAL−EN en 1008NH
1. Overview of components

Contents

1. Overview of components 1−1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1 The valve terminal MPA−L 1−3 . . . .
1.2 Valve terminal design 1−4 . . . . . . . . . .
1.3 Electrical multi−pin connection 1−5 . . . . . . . . . . . . . .
1.3.1 Versions of the connector 1−6 . . . . . . . . . . . . . . . . . . . . . . . .
1.3.2 Versions of the IP protection class 1−7 . . . . . . . . . . . . . . . . . . . . . . . . . .
1.4 Electrical connection via CPX terminal 1−8 . . . . .
1.5 Description of components 1−9 . . . . . . . . . . . . . . . . . . . . . .
1.5.1 Valves 1−9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.5.2 Main and additional power supply 1−10 . . . . . . . . . . . . . . . . . . . . . . . . . .
1.5.3 Pilot air supply 1−11
1.5.4 Exhaust air 1−13 . . . . . . .
1.5.5 Sub−bases and pressure zone separation 1−13 . . . . . . .
1.5.6 Vertical stacking 1−15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.5.7 Pressure regulating plates 1−16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.6 Connecting elements 1−20 . . . . . . . . .
1.7 Display and control elements 1−22 . . . . . . . . . . . .
1.7.1 Identification system" (as per catalogue) 1−23 . . . . . . . . . . . . . . . . . . .
1.7.2 Manual
1.7.3 Pressure regulator 1−24 . . . . . . . . . . .
1.7.4 Switching status displays for valves 1−25 . . . . . . . . . . . . . . . . .
override (MO) 1−23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . .
. . . .
. . . . . . . .
1−2
Festo P.BE−MPAL−EN en 1008N H
1. Overview of components
1.1 The valve terminal MPA−L
Festo supports your automation tasks at machine level with the valve terminal MPA−L. The modular structure of the valve terminal MPA−L enables you to match this valve terminal opti mally to your machine or system.
The valve terminal MPA−L provides the following connections:
Common ducts for supply and exhaust air
Electric signals from all
solenoid coils
Working lines (2) and (4) are provided for each valve position on the individual pneumatic sub−bases. The valves are sup plied with compressed air (operating pressure and pilot pres sure) via the common channels and connections in the basic components. The exhaust air (from the valves and the pilot exhaust air)
is also exhausted via these common channels. Further components for compressed air supply are also avail able, e.g. in order to supply pressure zones.
The valve terminal MPA−L is equipped with current reduction. The nominal current of the solenoid coils is then reduced after the high−current phase (switching procedure). The cur rent reduction offers
the following advantages:
The valve terminal MPA−L has a lower power consumption
The power unit for the voltage supply to the valve ter
minal MPA−L can be designed more economically depend ing on the individual case
The solenoid coils have less leakage power and produce
less waste heat
Festo P.BE−MPAL−EN en 1008NH
1−3
1. Overview of components

1.2 Valve terminal design

The valve terminal MPA−L consists of the following pneumatic and electric components: The most important components are shown in Fig.1/1.
1
2
3
1 Multipin sub−base with cover (here:
IP40 cover)
2 Pneumatic supply plate with exhaust
plate for ducted exhaust air (3/5)
3 Sub−base with electronic module and
valve or blanking plate
5
4
4 Sub−bases, 4 off set, with common
electronic module and valves or blanking plates
5 Vertical stacking (here: Pressure
regulator plate with installed valve and optional pressure gauge)
6 Right−hand end plate
6
Fig.1/1: Main components of the valve terminal MPA−L
1−4
Festo P.BE−MPAL−EN en 1008N H
1. Overview of components
The following operating modes can be used  independently of valve type:
Standard operation with one or more pressure zones
Reversible operation with compressed air supply via
connections (3), (5) and exhaust via port (1)
Low−pressure operation at 0 ... 3 bar
Vacuum operation at −0.9 ... 0 bar
1.3 Electrical multi−pin connection
The electrical connection of the solenoid coils is made cen trally via a multi−pin plug in the left−hand end plate, which is available in various variants for the he valve terminal MPA−L (see Tab.1/1). One or two solenoid coils per v alve position can be controlled. Each solenoid coil occupies one pin of multi−pin plug.
the
Festo P.BE−MPAL−EN en 1008NH
1−5
1. Overview of components

1.3.1 Versions of the connector

Multi−pin connection, Type of left−hand end plate
Plug type Number of controllable
solenoid coils
Sub−D with 9pins 1, 2, 3, ... 8
Sub−D with 25pins 1, 2, 3, ... 24
Sub−D with 44pins 1, 2, 3, ... 32
Terminal strip
1)
1, 2, 3, ... 32
Ribbon cable
1) Note that all cables to a cable harness must be grouped to ensure EMC conformity.
2) Note that all 0 V−/24V supply cables must be used and grouped to a cable harness.
2)
1, 2, 3, ... 32
Tab.1/1: Multi−pin plug types of the left−hand end plates
1−6
Festo P.BE−MPAL−EN en 1008N H
1. Overview of components

1.3.2 Versions of the IP protection class

For variants with sub−D plugs the multipin connection can be implemented with various cover types (see Tab.1/2).
Multipin sub−base
Cover types for sub−D plug
IP65 cover: closed cover, Protection class IP65, with pre−prepared cable Exclusively for the sub−D plug with 25−/44 pins.
IP40 cover: open cover, protection class IP40 (In this case: Sub−D with 25 pins
Tab.1/2: Multipin sub−base and cover types
.
Festo P.BE−MPAL−EN en 1008NH
1−7
1. Overview of components

1.4 Electrical connection via CPX terminal

The electrical interface of the solenoid coils on the CPX ter minal is made centrally via the pneumatic interface (see Fig.1/2). Per valve position one or two solenoid coils and within the valve terminal MPA−L maximum 32solenoid coils can be controlled via the CPX terminal.
1 CPX bus node
2 Pneumatic inter
face
1
3 Optional: addi
tional CPX module
4
4 Multipin sub−
base of the CPX terminal
2
3
Fig.1/2: Electric components of the valve terminal MPA−L with CPX terminal
1−8
Festo P.BE−MPAL−EN en 1008N H
1. Overview of components

1.5 Description of components

1.5.1 Valves

The valve terminal MPA−L can be fitted with 2x2/2−, 2x3/2−way valves, 5/2−way valves and 5/3−way valves and further valve types (see Tab.  1 /3 ).
Valve labelling The valves on the MPA−S valve terminal are marked by
identification codes (see Tab.1/3). By means of this identifi  cation on the top of the valve, you can ascertain the ment fitted on your valve terminal MPA−L.
equip
ID code
B 5/3−way valve, mid−position open
D Two monostable 2/2−way valves, normally closed, pneumatic spring return
DS Two monostable 2/2−way valves, normally closed, pneumatic spring return
I 5/3−way valve, mid−position exhausted
R 5/3−way valve, mid−position closed
H Two monostable 3/2−way valves, control side 12 normally open, control side 14
HS Two monostable 3/2−way valves, control side 12 normally open, control side 14
I Tw o 2/2−way valves, normally closed, pneumatic spring return
J 5/2−way double pilot valve
K Two monostable 3/2−way valves, normally closed, pneumatic spring return
KS Tw o monostable 3/2−way valves, normally closed, pneumatic spring return
Valve
normally closed, pneumatic spring return
normally closed, pneumatic spring return
With dual−pressure operation: Operating pressure via connection (1) or connection (5) With vacuum operation: Operating pressure at connection (1), Vacuum at connection (5) (e.g. for vacuum switching with ejector pulse)
Festo P.BE−MPAL−EN en 1008NH
1−9
1. Overview of components
ID code Valve
M Monostable 5/2−way valve
N Two monostable 3/2−way valves, normally closed, pneumatic spring return
NS Two monostable 3/2−way valves, normally open, pneumatic spring return
W Monostable 3/2−way valve, open in basic position, external compressed air
X Monostable 3/2−way valve, closed in basic position, external compressed air
L Blanking plate for sealing an vacant valve position
supply via connection 2
supply via connection (4)
Tab.1/3: Identification codes of the valves
Further information on the valves can be found in AppendixB.

1.5.2 Main and additional power supply

The main supply of the valve terminal with operating pressure can be made via a pneumatic supply plate (see Fig.1/3) or via the right−hand end plate with lateral ports (Tab.1/4 below).
1−10
Festo P.BE−MPAL−EN en 1008N H
1. Overview of components
1 Supply plate
2 Exhaust plate for
ducted exhaust air

1.5.3 Pilot air supply

2
1
Fig.1/3: Pneumatic supply plate
The pneumatic supply plate can also be used for additional power supplies. These are, forexample, necessary in the case of valve terminals operated with several pressure zones or when a large number of valves on the valve terminal are switched simultaneously to flow.
Festo P.BE−MPAL−EN en 1008NH
The pilot control of the solenoid coils is supplied with internal or external pilot air. This pilot air is made available for the complete valve terminal (also via the pressure zones) via the right−hand end plate (see Tab.1/4).
A selector plate on the right−hand end plate makes it possible to branch the pilot take it from the separate supply via the port (12/14).
Note
Internal pilot air supply is only permitted if the operating pressure of the last pressure zone (at the right−hand end plate) is between 3 and 8 bar .
air internally from the supply port (1) or to
1−11
1. Overview of components
End plate type Properties
End plate without connections at side
space−saving, low end plate with front, round selector
plate
separate pneumatic supply plate required for the valve
terminal
End plate with exhaust ports at side
high end plate with upper, square selector platesupply connections (1), (3) and (5) are integrated at the
side
Tab.1/4: Right−hand end plate versions
The way in which the pilot control of your valve terminal is set can be determined from Tab.1/5. The conversion between the internal and external pilot air supply is described in Chapter 5.3.5.
1−12
Festo P.BE−MPAL−EN en 1008N H
1. Overview of components
Pilot control variant
Properties Internal pilot air supply External pilot air supply
Identification on the end plate/ Setting of the selector plate
Type of pilot air supply Internally from the supply
Requirement The operating pressure must be
Int" Ext"
port(1) distributed operating pressure
in the range 3...8bar and be free of pressure fluctuations.
Tab.1/5: Features of the pilot control variants

1.5.4 Exhaust air

The exhaust (3) and (5) of the air is exhausted together via the flat plate silencer and the exhaust plate or separately via the right−hand end plate with ports at the side.
The pilot exhaust air (82/84) is led to a connection on the right−hand end plate and can either be ducted there hausted via a silencer.
1.5.5 Sub−bases and pressure zone separation
Externally via the pilot connection (12/14) supplied, separately controllable pressure (3...8 bar )
The operating pressure can be below 3bar and above 8bar , so long as separately controlled pilot pressure (3...8bar) is availabl e.
or ex
Festo P.BE−MPAL−EN en 1008NH
The valves of valve terminal MPA−L are supplied pneumati cally via the sub−bases and via the electronic module that is installed in the sub−base (see Fig.1/4).
In addition to the individual sub−bases there are also the 4 off sub−bases with common 4 off electronic module.
1−13
1. Overview of components
1 Sub−base
2 Electronics
module
2
1
Fig.1/4: Sub−base with electronic module
In addition valves within a valve terminal MPA−L can be sup plied with different pressures by creating different pressure zones. The separation of the pressure zones is achieved by special sub−bases. In each case the valve mounted to the right of the special sub−base belongs to the next (following to the right) pressure zone, which is the valve mounted on the special sub−base in the current pressure zone.
The sub−bases with integrated pressure zone separation are in various versions with corresponding identification (see Tab.1/6):
on
1−14
Festo P.BE−MPAL−EN en 1008N H
1. Overview of components
Sub−base design MPA1
Supply duct (1) separated
Exhaust ducts (3) and (5) separated
Supply channel (1) and exhaust ducts (3) and (5) separate
Type: VMPAL−AP−...−T1
Type: VMPAL−AP−...−T135
Type: VMPAL−AP−...−T135
Tab.1/6: Variants of the sub−bases with integrated pressure zone separation
Pressure zone separation of the pilot channels (12) and (14) is not provided, as on the valve terminal MPA−L the air supply for the pilot control of the valves is supplied centrally via the right−hand end plate.

1.5.6 Vertical stacking

Festo P.BE−MPAL−EN en 1008NH
You can fit further pneumatic components to each valve position between the sub−base and the valve. These vertical stackings enable you to implement certain additional func tions as desired.
1−15
1. Overview of components
Components
Tab.1/7 shows the main structure and possible components of the vertical stacking.
Directional control valves
Vertical stacking, optional
Sub−base Type VMPAL−AP−... with electronics module
See chapter  1.5.1.
 Pressure regulator plate
Type VMPA...B8−R... C2−C−... (Pressure gauge optional), see Chapter 1.5.7
 Pressure shut−off plate, Type VMPA1−HS
Tab.1/7: Components of the vertical stacking

1.5.7 Pressure regulating plates

Mode of operation A pressure regulator plate with adjustable pressure regulator
can be installed between the sub−base and the valve in order to control the force of the connected actuators. This pressure regulator maintains an essentially constant output pressure (secondary side) independent of supply pressure (primary side) and air consumption.
Identification The pressure regulator plates of
marked on the valve terminal MPA−L with the Ident. code. This is marked on the side of the pressure regulator plate. Using Tab.1/8 you can identify the pressure regulator plates.
1−16
the vertical stacking are
Festo P.BE−MPAL−EN en 1008N H
Loading...
+ 130 hidden pages