Radio Thermostat Mechanical clock
Part number: ZU0800013
Installation & User Instructions
Suitable for Ferroli Modena C HE combination boilers

Contents
Page number
Short Description 3
Safety Instructions 3
Installation of controller 5
Location
5
Mounting the Wall Plate 6
Battery installation 7
8
9
Setting instructions
Setting the time
10
Setting on/off periods
11
Setting Max/Min room temperatures
12
Manual Switch
13
Warranty
14
15
16
17
18
19
20
2

Short Description
Short description Radio Thermostat Clock – Transmitter
The radio thermostat mechanical clock is a 24 hour radio frequency (RF)
wireless thermostat/ timer which communicates with a special receiver designed to fit in the clock aperture of the boiler casing.
The radio thermostat mechanical clock is battery powered and can be sited
wherever conventional room thermostats would normally be sited.
See installation locations information on page
The radio thermostat mechanical clock is a room thermostat and clock of
highly advanced technology. The device is wireless and controls the heating
via radio, providing both time control and comfortable room temperatures.
Safety Instructions
Safety Instructions
Both receiver and transmitter should be fitted by a competent person.
It is imperative to observe the generally applicable safety measures, such as:
Before starting any work on fitting the receiver, switch off power supply and
secure against switching on.
Do not use any metallic and sharp pointed objects for the operation of the
keys.
For technical data, see label on the unit or data sheet.
I
3

Rear view of receiver
Live (brown) – Terminal 1
Neutral (blue) – Terminal 2
Switching wires – Terminals 3 & 4
4

Modena C HE
T1
81
These spades
connect to
terminals 1 & 2 at
the clock
ABM03
X6
104
ON/OFF
SWITCH
(configurable)
138
1
1
X4
18
X3
1
24
X2
FUSE 3.15A
250V
1
2
12
X1
1 2 3 4
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9 1 0 11 1 2 1 2 3 4 5 6 1
10 11 1 2 13 14 15 16 17 18
13 14 15 16 17 18 19 2 0 21 2 2 23 2 4
7 8 9 1 0 11 12 2
White
White
N
L
114
230V
AUX
N
L
186 44
136
TACHO
PWM
191
1
8
T T
T
278
42
16
32
203
230V
50Hz
Wiring diagram
Remove Link and
connect leads to
terminals 3 & 4 at the
receiver