Ferroli ZU0800009 Installation & User's Instructions

Installation & User Instructions Part number: ZU0800009
Radio Thermostat Clock
80.10.1375.7_feeling_ks_fer_en.indd 1 18.04.2013 11:25:42
2
Table of contents
Safety instructions ............................... 3
Product details ..................................... 4
Installation and assembly ..................... 7
Operating and adjustment .................. 15
Conguration ..................................... 18
Initial start-up .................................... 19
Settings ............................................. 25
Operating modes ............................... 29
Operating status ................................ 36
User menu/Conguration ................... 39
Installation menu ............................... 40
80.10.1375.7_feeling_ks_fer_en.indd 2 18.04.2013 11:25:42
3
Danger from electric shock!
The connection and installation of electrical devices may only be carried out
by a qualied electrician.
DANGER
• It is imperative to observe the generally applicable safety measures, e.g. before starting any work on the appliance, switch off power supply and secure against switching on.
• Interventions in and changes to the device result in the voiding of the warranty claim.
• Observe your national regulations and the respective safety provisions.
80.10.1375.7_feeling_ks_fer_en.indd 3 18.04.2013 11:25:42
4
A B
C
D
E
F
Product details
The radio thermostat clock is a 7 day radio frequency (RF) wireless thermostat/ timer which communicates
with a special receiver designed to t in the clock
aperture of the boiler casing.
The radio thermostat clock is battery powered and can be sited wherever conventional room thermostats would normally be sited. See installation locations information on page 7.
The radio thermostat clock is a room thermostat and clock of highly advanced technology. The device is wireless and controls the heating via radio, providing both time control and comfortable room temperatures.
Assembly description
A Moveable sliding cover B Keys for manual override
function
C Window D Keyboard E Battery compartment
F Display
80.10.1375.7_feeling_ks_fer_en.indd 4 18.04.2013 11:25:43
5
Technical data – RF Set, Transmitter
Power supply: 2 x 1.5 V AA LR6 alkaline batteries Battery service life: 2 years (depending on switching frequency) Room temperature display resolution: 0.1ºC Temperature setting display: Program: +5ºC…+32ºC (0.5ºC steps) Frost protection: 5ºC (adjustable 3ºC…7ºC) Time setting resolution: Time of day: 1 minute Program: 30 minutes Programming: weekly program with up to 48 time and temperature programs changes
Pre-programmed programs: 4 + 1 user-dened
RF signal: 868.3 MHz RF signal range: Indoor 30 m (2 walls + 1 ceiling) Protection class / type: II / IP40 Operating temperature range: Max. 45ºC Operating humidity range: 10% to 90% RH non-condensing Dimensions H x W x D (mm): 87 x 154 x 27
80.10.1375.7_feeling_ks_fer_en.indd 5 18.04.2013 11:25:43
6
Technical data – RF Set, Receiver
Power supply: 230 V +/-10% 50-60 Hz Switching output: SPDT (potential-free) Switching capacity: 5 (1) A 250 V AC RF signal: 868.3 MHz RF signal range: Indoor 30 m (2 walls + 1 ceiling) Protection class / type: II / IP20 Operating temperature range: Max. 45ºC Operating humidity range: 10% to 90% RH non-condensing Dimensions H x W x D (mm): 60 x 60 x 32
80.10.1375.7_feeling_ks_fer_en.indd 6 18.04.2013 11:25:43
7
1.5 m
Installation and assembly
General information
80.10.1375.7_feeling_ks_fer_en.indd 7 18.04.2013 11:25:43
8
Modena C HE
80.10.1375.7_feeling_ks_fer_en.indd 8 18.04.2013 11:25:43
9
Wiring diagram
These spades connect to terminals 1 & 2 at the clock
Remove Link and connect leads to terminals 3 & 4 at the receiver
White
L
White
N
Radio Thermostat
Clock Receiver
80.10.1375.7_feeling_ks_fer_en.indd 9 18.04.2013 11:25:44
10
Wiring Connections
1 - Live (Brown) 2 - Neutral (Blue) 3 - Switched circuit (White #1) 4 - Switched circuit (White #2) 5 - No connection required
Commissioning, please turn to page 11.
Receiver Button LED
Installation of the receiver
M
~
1
23
45
80.10.1375.7_feeling_ks_fer_en.indd 10 18.04.2013 11:25:44
11
Receiver Button
Installation of the radio link
The transmitter and receiver are pre-commissioned. If the radio link doesn‘t work correct,
follow the sequence of commissioning.
Press and hold the black button of the receiver until the LED light has ashed twice. Release the
button and the LED light will remain illuminated. Press and hold MODE-button and SET-button of the transmitter at the same time for more than 3 seconds to enter into the User menu. Then press the OK-button until RF Comm is displayed.
80.10.1375.7_feeling_ks_fer_en.indd 11 18.04.2013 11:25:44
12
Press upper + button (– button disables the RF signal) to enable an continous RF signal. The receiver LED will go out as soon as a signal from the transmitter is received. Then press the OK-button, the radio link between transmitter and receiver is now established. Press the ESC-button to return to Auto mode.
Receiver: When operating in heating mode and an ON signal is received, the LED illuminates
continously. When an OFF signal is received, the LED is off (and ashes periodically at longer
intervals). Is no valid radio signal received from the transmitter for more than one hour (e.g. low
battery) the emergency operating mode will be activated. The LED ashes every 0,5 seconds.
80.10.1375.7_feeling_ks_fer_en.indd 12 18.04.2013 11:25:45
13
Open housing Wall mounting
80.10.1375.7_feeling_ks_fer_en.indd 13 18.04.2013 11:25:45
14
Only use 2 x 1.5 V type AA.
click!
click!
Close housing Insert batteries
80.10.1375.7_feeling_ks_fer_en.indd 14 18.04.2013 11:25:46
Loading...