Modena HE
High efficiency condensing combination and system boilers
21st century design for 21st century life
High efficiency Condensing combination boilers
27c and 32c
System boilers
18s, 25s and 32s
SEDBUK
A
only
4 moving parts
5year
full 5 year parts and
labour warranty
2year
full 2 year parts and
labour warranty
or
Page 2
*UK warranty is subject to terms and conditions – please refer to the document enclosed with the boiler or contact our service department for further information.
Ferroli is one of Europe’s leading manufacturers of heating solutions for domestic, commercial and industrial requirements. We pride ourselves on using the latest technological advances to achieve optimum energy efficiency whilst ensuring environmental protection. This means that when you choose a new Ferroli high efficiency condensing boiler for your home, you can be assured that you have chosen one of the most sustainable and cost-effective ways to generate heat and hot water.
We also understand that reliability is your number one concern and that is why the Modena HE range is available with a choice of a 5 or 2 year full parts and labour manufacturer’s warranty*.
Reliability reassurance with
Modena HE
High efficiency combination and system boilers
2
Page 3
Free backup
Ferroli offers a complete one-stop-shop solution
SPECIFICATION AND TECHNICAL SUPPORT
Installers, merchants, specifiers and developers can call Ferroli’s technical support team at any time for specification guidance or technical support.
AFTERSALES
With a national team of dedicated engineers across the UK, Ferroli is always ready and able to provide support to installers and homeowners alike. Be that a repair or annual service, our aim is to ensure your Ferroli boiler works efficiently for years to come.
Ferroli engineers carry a comprehensive stock of spare components to ensure first fix where possible and we also have a nationwide network of Ferroli spare part stockists.
Service & Technical Support T: 0843 479 0479 F: 0843 479 0082
Sales & Spares T: 0843 479 4790 F: 0843 479 0081
General Enquiries T: 0843 479 0009
We pride ourselves on being able to offer much more than simply high specification, value for money products. We aim to provide our customers with unbeatable knowledge, support and service that extends beyond the sale of the product.
with every Ferroli boiler
Calls to these numbers are charged at national rate from BT landlines. Calls from mobile networks may be considerably more.
Engineer Customer services Training Designer
Manufacturer
Engineer
Customer services Training DesignerManufacturer
Customer services
Training DesignerManufacturer
Training
DesignerManufacturer
Designer
3
Page 4
2year
warranty
5year
warranty
Modena HE
High efficiency boilers Combination 27c and 32c System 18s, 25s and 32s
Height 600mm, Width 400mm, Depth 320mm
Weight 28kg (18s & 25s), 29kg (27c), 30kg (32s) and 31.5kg (32c)
Operating noise level <40dB
NOx Class 5 rated for extremely low emissions and high performance
SEDBUK Band A rated for excellent fuel cost economy and energy efficiency
Operates on both natural gas and LPG
Combi models have only 4 moving parts – DHW water flow meter, pump, fan and gas valve - and system models have only 3
Accessories available include valve cover, rear pipe space frame and a choice of four mechanical and digital clocks and room thermostat controls
Combi models condense in hot water mode
All components can be serviced or removed via front panel
Central flueing for easy replacement installations
Microprocessor control and adjustment system with advanced self-diagnosis
The Modena HE range sets a new standard for the domestic boiler market. It is the smallest, lightest and quietest boiler in its class and comes with a choice of a 5 or 2 year full parts and labour manufacturer’s warranty.
NOx Class 5 and SEDBUK A ratings demonstrate the Modena’s outstanding energy efficiency standards to provide what every customer wants – an exceptionally reliable boiler that combines high performance with lower fuel bills.
At just 600mm high the Modena can be sited in the most awkward of spaces; a liftweight of between 28kg and 31.5kg allows for one-man installation and an operating noise level of less than 40dB means it can hardly be heard.
Choice of 5 or 2 year full parts and labour manufacturer’s warranty* for total peace of mind and reassurance
Please note: System models come without a timer.
*UK warranty is subject to terms and conditions – please refer to the document enclosed with the boiler or contact our service department for further information.
up to
31
.3
kW
max
OUTPUT
32c DHW
flow rate
13
.1
l/min
@ t 35°C
MODENA
comes with
filling
loop
moving
parts
only
4
optional
digital RF
programmable
room
thermostat
4
Page 5
Robust stainless steel burner for long life
Optional external temperature sensor kit
Dry fit sensors mean they can be replaced without draining the system
Flexible flue options from coaxial single pipe to twin pipe; white or translucent options for visual inspection in voids
All Modena boilers are fully compatible and ready to work with renewable energy products
DHW/central heating heat exchangers can be chemically cleaned and flushed in situ
Combination System
27c 32c 18s 25s 32s
Ferroli product codes
Natural Gas 5yr Warranty
0T1R2IGA 0T1R3IGA 0T2O1IGA 0T2O2IGA 0T2O3IGA
Natural Gas 2yr Warranty
ZU0T1R2IGA ZU0T1R3IGA ZU0T2O1IGA ZU0T2O2IGA ZU0T2O3IGA
LPG 5yr Warranty
0T1R2KGA 0T1R3KGA 0T2O1KGA 0T2O2KGA 0T2O3KGA
LPG 2yr Warranty
ZU0T1R2KGA ZU0T1R3KGA ZU0T2O1KGA ZU0T2O2KGA ZU0T2O3KGA
NOx emissions class (mg/kWhr) 5 5 5 5 5
Energy marking rating (92/42 EEC directive)
HHHH HHHH HHHH HHHH HHHH
SAP 2009 annual/2005 seasonal efficiency % NG 89.2/90.3 89.2/90.3 89.2/90.2 89.2/90.2 89.3/90.4
LPG 90.2/92.2 90.2/92.2 90.3/92.3 90.3/92.3 90.3/92.3
Output max/min
Heat input kW
25.0/5.8 29.5/6.7 17.4/4 25/5.8
32/6.07
Useful heat output 80°C – 60°C kW
24.5/5.7 28.9/6.6 17/3.9 24.5/5.7
31.4/6.6
Useful heat output 50°C – 30°C kW
26.5/6.2 31.3/7.2 18.5/4.3 26.5/6.2
34/7.2
Central heating
Maximum operating temperature ºC
80 80 80 80 80
Operating pressure central heating Max. bar
3 3 3 3 3
Min. bar
0.8 0.8 0.8 0.8 0.8
Expansion vessel capacity litres
8 10 8 8 10
Expansion vessel pre-fill pressure bar
0.8 0.8 0.8 0.8 0.8
Boiler water content litres
1.7 2.1 1.7 1.7 1.7
DHW
Maximum DHW production t 25°C l/min
15.5 18.3 - - -
t 30°C l/min
12.9 15.3 - - -
t 35°C l/min
11.1 13.1 - - -
Operating pressure DHW Max. bar
9 9 - - -
Min. bar
0.3 0.3 - - -
Dimensions & weights
Height mm
600 600 600 600 600
Width mm
400 400 400 400 400
Depth mm
320 320 320 320 320
Weight (empty) kg
29 31.5 28 28 30
Fittings
Gas fitting mm
22 22 22 22 22
Central heating fittings mm
22 22 22 22 22
DHW circuit fittings mm
15 15 - - -
Power supply
Max power input W
100 120 100 100 100
Power supply voltage/frequency V/Hz
230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz 230/50
Index of protection IP
IPX5D IPX5D IPX5D IPX5D IPX5D
Maximum equivalent flue lengths
Max horizontal flue length 60/100mm Ø m
7 7 7 7 7
Max vertical flue length 60/100mm Ø m
8 8 8 8 8
Max horizontal flue length 80/125mm Ø m
28 28 28 28 28
Max vertical flue length 80/125mm Ø m
28 28 28 28 28
Total equivalent length two pipe 80mm Ø m
80 70 70 70 70
Filling loop
Yes Yes No No No
Hanging bracket
Yes Yes Yes Yes Yes
Pre-wired mains cable supplied
Yes Yes Yes Yes Yes
Technical specifications
5
Page 6
Flues
Accessories Manufacturer’s Ref
Telescopic Flue 60/100mm – nominal length 610mm 041049G0 Flue Extension 60/100mm Ø – nominal length 1m 1KWMA57W Elbow 45°– 60/100mm Ø 1KWMA64W Elbow 90°– 60/100mm Ø 041051X0 Flue Vertical Termination 60/100mm Ø 1KWUK356 Appliance Adaptor for Vertical Flue 60/100mm Ø 041002X0 Bracket – Flue Support 100mm Ø 1KWMR46A Roof Flashing Plate – Flat Roof Ø 1KWMA81U Roof Flashing Plate – Pitched Roof Ø 1KWMA82U Pluming Kit – 60/100/60mm Ø (with flue kit combined) 041042G0 Appliance Adaptor (Pair) for Twin 80mm Ø 041039X0 Flue Extension 80mm Ø – nominal length 1m 222952 Elbow 45°– 80mm Ø 222954 Elbow 90°– 80mm Ø 222955 Terminal (Air Intake) for Twin 80mm Ø Horizontal 1KWMA85A Terminal (Flue Exhaust) for Twin 80mm Ø Horizontal 1KWMA86A Bracket – Flue Support 80mm Ø 1KWMR48A Flue Vertical Termination Twin Connection 80mm Ø 010027X0 Standard Rigid Flue Kit 60/100mm – 1m 041025G0
Boiler Control and Accessory Options Manufacturer’s Ref
Digital Timer (diameter 61.5mm)
013021XA
Mechanical Timer
ZU0800510
Digital RF Programmable Room Thermostat
ZU0800009
Mechanical RF Programmable Room Thermostat
ZU0800013
Rear Pipe Space Frame (depth 65mm)
056000G0
Valve Cover
046035G0
External Weather Compensator (combi only)
013018X0
Digital Timer (diameter 40mm)
013001X0
S
Please contact Ferroli Sales for other 80/125 mm Ø flue options and accessories not shown. Note For non standard flue lengths over 1m a fall of 3o per metre per length should be incorporated back to the boiler. Consult manufacturer’s installation instructions for full guidance and options for flueing.
A A
B
C
D
Clearances
A 0.5cm (minimum) B 20cm (minimum) C 30cm (minimum) D 60cm (minimum)
via an openable panel
Essential to the boiler’s operation is the availability of fresh, clean air and the ability to dispose of combustion products. This is achieved through the installation of a flue which provides ducts to the outside of the premises.
To optimise safety and performance, Ferroli flues must always be used with Ferroli boilers. Ferroli has a comprehensive range of accessories to suit complex installations and to enable the extension of flue lengths. The diagram above shows typical flueing options.
A
K
L
O
P
N
M
S
D
B
F
C
E
B
F
I
C
B
S
S
B
S
D
S
S
or
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
6
Page 7
Digital RF Programmable Room Thermostat
Mechanical RF Programmable Room Thermostat
H
H
I
J,K
B
I
Q
A
G
I
M
N
F
L
D,E
C
Likely flue positions requiring a flue terminal guard
P
Q
A
P
N
M
I
G
I
H
H
K
J
Q
C
I
Q
D
E
B
F
L
Flue Terminal Positions mm
Directly below an opening, air brick, opening windows etc. 300
Above an opening, air brick, opening windows etc. 300
Horizontally to an opening, air brick, opening windows etc. 300
Below gutters, soil pipes or drain pipes 75
Below eaves 200
Below balconies or car port 200
From a vertical drain pipe or soil pipe 150
From an internal or external corner 100
Above ground roof or balcony level 300
From a surface facing the terminal 600
From a terminal facing the terminal 1200
From an opening in the car port (ie. door, window) into the dwelling 1200
Vertically from a terminal on the same wall 1500
Horizontally from a terminal on the same wall 300
From the wall on which the terminal is mounted N/A
From a vertical structure on the roof 150
Above intersection with roof 300
300 min
Terminal
Assembly
Top View Rear Flue
Property
Boundary Line
Notes
In addition, the terminal must not be nearer than 300mm to an opening in the building fabric formed for the purpose of accommodating a built-in element such as a window frame.
Condensing terminal positions: if the flue is to be terminated at low level then the potential effect of the plume must be considered.
The plume should not be directed: – across a frequently used access route – towards a window – across a neighbouring property
For more information on terminal positions please contact our technical department.
The distance from a fanned draught appliance terminal installed parallel to a boundary may not be less than 300mm in accordance with the diagram below.
Flue terminal positions
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
Digital Timer
Mechanical Timer
RF Receiver (internal)
RF Receiver (internal)
+
+
Valve Cover
Rear Pipe Space Frame
7
Page 8
Modena/10.13
CONTACT US IN THE UK
SALES
T:
0843 479 4790
F:
0843 479 0081
sales@ferroli.co.uk
SERVICE
T:
0843 479 0479
F:
0843 479 0082
service
@
ferroli.co.uk
GENERAL ENQUIRIES
T:
0843 479 0009
generalenquiries
@
ferroli.co.uk
TWITTER
twitter.com/ferroliuk
Ferroli Limited
Lichfield Road Branston Industrial Estate Burton-upon-Trent Staffordshire DE14 3HD
Ferroli has been producing heating appliances and equipment since the 1950s. Today, their ultra­modern factories in Europe employ over 2,500 people and produce a wide range of wall hung, cast iron and welded steel boilers, making Ferroli one of the largest and most successful heating appliance manufacturers in the world.
Ferroli Domestic Boilers Offering gas wall mounted units with outputs of up to 50kW, Ferroli’s stylish, compact domestic boilers provide maximum comfort with minimal fuel usage. With a choice of conventional, condensing and combi technologies, there’s a boiler to match the heating and hot water requirements of every home.
Ferroli Commercial and Industrial Boilers Ferroli
commercial boilers for pressure jet oil, forced air gas or dual fuel are factory matched with high efficiency burners to provide outputs of up to 12,350kW, whilst meeting the strictest emissions demands.
Ferroli Renewable Energy Products Ferroli continues to meet
the latest demands for renewable energy technologies. From domestic air source heat pumps to drain back and pressurised solar systems, Ferroli has the products to suit the most popular renewable energy system options.
Ferroli Spares The popularity of Ferroli as first choice for both domestic and commercial installations means that heating parts stockists offer readily available spares for Ferroli boilers. Ferroli has a UK-based fully stocked warehouse enabling same-day despatch of just about any part needed to keep your Ferroli boiler running.
www.ferroli.co.uk
Calls to the above numbers are charged at national rate from BT landlines. Calls from mobile networks may be considerably more. Whilst every effort is taken to ensure the accuracy of the information contained within the brochure, the details are offered in good faith and Ferroli Ltd. accepts no liability for matters arising as a result of errors and/or omissions. The information in this brochure was correct at the time of printing, however specifications and designs may be changed owing to Ferroli’s policy of continuous product research and development. The technical specifications in the product instruction manual supersedes and should always be referred to during installation and maintenance. Reproduction of this publication, or any part, is not permitted without the written consent of Ferroli Ltd at marketing@ferroli.co.uk. The statutory rights of the consumer are not affected.
Your local Ferroli stockist
Training Well trained installers are the key to a safe and efficient heating system. We offer a choice of training and product awareness courses on our key product range, including the Modena HE, at Ferroli’s fully equipped training centre in Burton-upon-Trent and at specialist training locations across the UK. Courses are aimed at engineers of all levels to ensure that everyone comes away with the skills and knowledge needed to deliver the first class service that customers expect and deserve. For more details visit www.ferroli.co.uk/training or ring 0843 479 0009.
Loading...