Ferroli Domina F 24-30 E, Ferella F 24-30 MEL, MILOS Air Compact E Technical Manual

Page 1
Supplied By www.heating spares.co Tel. 0161 620 6677
Wall-Mounting Gas Boiler
Airtight Chamber, for Hot Water and Heating
TECHNICAL
DOMINA F 24-30 E
FERELLA F 24-30 MEL
MILOS AIR COMPACT E
MANUAL
EDITION
092002
Page 2
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
1. Technical characteristics and data ......................................................... 3
1.1 Introduction ............................................................................................................3
1.2 Dimensions and connections .................................................................................. 4
1.3 General view and main components ...................................................................... 8
1.4 Technical data table .............................................................................................. 10
2. Product framework and internal components..................................... 11
2.1 Hydraulic circuit - heating..................................................................................... 11
2.2 Hydraulic circuit - tap water ................................................................................. 15
2.3 Gas circuit .............................................................................................................17
2.4 Burner unit ............................................................................................................21
2.5 Fume circuit .......................................................................................................... 23
2.6 Electrical circuit..................................................................................................... 27
3. Operation ............................................................................................ 30
3.1 Operating principle .............................................................................................. 30
3.2 Operating diagram ...............................................................................................31
3.3 Control panel ........................................................................................................ 32
3.4 Adjustments.......................................................................................................... 32
3.5 Setting operating parameters .............................................................................. 33
4. Troubleshooting .................................................................................. 34
2
Version - 09.2002
Page 3
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
1. TECHNICAL CHARACTERISTICS AND DATA GENERAL
1.1 Introduction
Our appliance is a high-efficiency heat generator for central heating and hot-water production running on natural gas or LPG (configurable at the time of installation).
The boiler shell consists of a copper laminar exchanger whose particular shape guarantees high exchange efficiency under all operating conditions and an open-flue burner equipped with electronic ignition and ionization flame control.
The boiler is totally sealed off from the installation room: the air needed for combustion is drawn from outside and the flue gases are expelled by a fan. The boiler outfit moreover includes a variable speed circulator, expansion tank, flow meter, safety valve, filler cock, air pressure switch, water pressure switch, temperature sensors and a safety thermostat.
Thanks to the control and adjustment system, unit operation is for the most part automatic. The power for heating is automatically governed by the control system according to the indoor characteristics, the characteristics of the building and of its location. The power for hot water is automatically and continually governed to ensure a fast delivery and comfort under all operating conditions.
There are 5 LEDs on the control panel providing information on the unit's operating status.
General Warnings
Installation and maintenance must be carried out by professionally qualified personnel,
according to current regulations and the manufacturer's instructions.
Incorrect installation or poor maintenance can cause damage or physical injury. The
manufacturer declines any responsibility for damage caused by errors in installation and use or by failure to follow the manufacturer's instructions given in the instructions manual.
Before carrying out any cleaning or maintenance operation, disconnect the unit from the
electrical power supply using the switch and/or the special cut-off devices.
Certification
The CE marking demonstrates that Ferroli gas units conform to the requirements contained in the applicable European directives. In particular, this unit complies with the following EU directives:
Gas Appliance Directive 90/396 assimilated with Italian Presidential Decree DPR 15.11.96 no. 661  Efficiency Directive 92/42 assimilated with Italian Presidential Decree DPR 15.11.96 no. 660  Low Voltage Directive 73/23 (amended by 93/68)  Electromagnetic Compatibility Directive 89/336 (amended by 93/68) assimilated with Italian
Presidential Decree DPR 15.11.96 no. 615
Version - 09.2002
3
Page 4
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
1.2 Dimensions and connections
Domina F 24 E version
Top view
Key
1 System delivery 2 Tap water outlet 3 Gas inlet 4 Tap water inlet 5 System return
4
Bottom view
Version - 09.2002
Page 5
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
Ferella F 24 MEL version
& Milos Air Compact E version
Top view
Key
1 System delivery 2 Tap water outlet 3 Gas inlet 4 Tap water inlet 5 System return
Version - 09.2002
Bottom view
5
Page 6
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
Domina F 30 E version
Top view
Key
1 System delivery 2 Tap water outlet 3 Gas inlet 4 Tap water inlet 5 System return
6
Bottom view
Version - 09.2002
Page 7
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
Ferella F 30 MEL version
Top view
Key
1 System delivery 2 Tap water outlet 3 Gas inlet 4 Tap water inlet 5 System return
Version - 09.2002
Bottom view
7
Page 8
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
1.3 General view and main components F 24 E/MEL version
Key
5 Airtight chamber 7 Gas inlet 8 Tap water outlet
9 Tap water inlet 10 System delivery 11 System return 14 Safety valve 16 Fan 19 Combustion chamber 20 Burner unit 21 Main nozzle 22 Burner 26 Combustion chamber insulation 27 Copper exchanger for heating and tap
28 Fume manifold 29 Fume outlet manifold 32 Heating circulator 34 Heating temp. sensor 36 Automatic air vent 42 Tap water temperature sensor 43 Air pressure switch 44 Gas valve 49 Safety thermostat 50 Heating thermostat 56 Expansion tank 63 Heating temperature setting 73 Antifreeze thermostat (optional)
R1-R2-R3-R4 Antifreeze heating elements
74 Heating system cock 81 Ignition electrode 82 Detection electrode 84 1st gas valve operator 85 2nd gas valve operator 90 Fume detection point 91 Air detection point 98 Off-On-Reset switch
114 Water pressure switch 132 Fume deflector 136 Flow meter 145 Water gauge 157 Tap water temperature setting 187 Fume diaphragm
water
(optional)
Version DOMINA - FERELLA - MILOS
8
Version - 09.2002
Page 9
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
F 30 E/MEL version
5 Airtight chamber 7 Gas inlet 8 Tap water outlet
9 Tap water inlet 10 System delivery 11 System return 14 Safety valve 16 Fan 19 Combustion chamber 20 Burner unit 21 Main nozzle 22 Burner 26 Combustion chamber insulation 27 Copper exchanger for heating and tap
water
28 Fume manifold 29 Fume outlet manifold 32 Heating circulator 34 Heating temp. sensor 36 Automatic air vent 42 Tap water temperature sensor 43 Air pressure switch 44 Gas valve 49 Safety thermostat 50 Heating thermostat 56 Expansion tank 63 Heating temperature setting 73 Antifreeze thermostat (optional)
R1-R2-R3-R4 Antifreeze heating elements
(optional)
74 Heating system cock 81 Ignition electrode 82 Detection electrode 84 1st gas valve operator 85 2nd gas valve operator 90 Fume detection point 91 Air detection point 98 Off-On-Reset switch
114 Water pressure switch 132 Fume deflector 136 Flow meter 145 Water gauge 157 Tap water temperature setting 187 Fume diaphragm
Version DOMINA - FERELLA
Version - 09.2002
9
Page 10
Supplied By www.heating spares.co Tel. 0161 620 6677
1.4 Technical data table
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
10
Version - 09.2002
Page 11
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
2. PRODUCT FRAMEWORK AND INTERNAL COMPONENTS
2.1 Hydraulic circuit  heating
Hydraulic diagram for heating
When there is a call for heat, the room thermostat or control system make the burners ignite and the circulation pump come into operation. The heat contained in the products of combustion is transferred to the water by the system via the exchanger. For more details on the operating logic, refer to chap.3.
29-187
16
49
27
82
20
42 34
114
14 74
-
+
5
43
50
56
81
44
32 136
Key
5 Airtight chamber 7 Gas inlet 8 Tap water outlet
9 Tap water inlet 10 System delivery 11 System return 14 Safety valve 16 Fan 20 Burner unit 27 Heat exchanger 29 Fume outlet collar 32 Heating circulator 34 Heating temperature sensor 42 Tap water temperature
sensor
43 Air pressure switch 44 Gas valve 49 Safety thermostat 50 Heating thermostat 56 Expansion tank 74 Heating system cock 81 Ignition electrode 82 Detection electrode
114 Water pressure switch 136 Flow meter 187 Fume diaphragm
10
Version - 09.2002
8
7
9
11
11
Page 12
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
Circulator (230v/50Hz)
Located on the heating circuit return, it is connected directly to the exchanger via special forks and connected to the system via a threaded brass section. It has three delivery/head levels (see diagram). Changing the delivery/head changes the speed of the water flowing through the boiler exchanger and as a result the temperature difference ( T) between heating delivery and return. Clearly, increasing the delivery of the circulator decreases T and vice versa. If it is not used for a long time, the impeller might jam due to debris in the water. With the front screw it is possible to access the impeller, which can be freed with the aid of a screwdriver. The connection to the expansion tank and the air separator is installed on the pump casing.
Checks
If the pump doesn't work:  Check that the impeller is free to turn by turning the screw on the front
with a screwdriver.  Check that both the card and the pump connection are powered.  If there is no power supply, check the card.  If there is power, change the pump.
Key
1 - 2 - 3 = Pump selector position
A = Losses of head 24kW version B = Losses of head 30kW version
Air separator
This is used to expel the air in the heating circuit automatically. On boilers with a twin heat exchanger, it is located on the pump casing. It is normally accessible either via the fork or by simply unscrewing it from its seat.
12
Version - 09.2002
Page 13
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
Expansion tank
It is connected to the pump casing via a pipe with a fork connection. On the 24kW version, it is located above the pump, while on the 30kW version it is located behind the exchanger, inside the frame. The expansion tank contains a diaphragm in contact, on one side, with the system water and, on the other side, with the air under pressure (pre-loaded to 1 bar) inside the tank. By the expansion of the diaphragm and ensuing compression of the air, the tank compensates for the thermal expansion of the water in the heating system.
24kW 7-litre
version
30kW 10-litre
version
Twin Heat Exchanger
The exchanger is a copper laminar assembly. It comprises a thickly finned portion, three circular pipes containing the heating water and, inside them, another three pipes in the form of a spiral containing the tap water. The heating water exchanges directly with the burnt gases, while the tap water does not have this kind of exchange, it receives heat indirectly from the water in the three heating pipes. In this way, the surface of the coil does not reach very high temperatures so less scale gets formed. In addition, being very small, it makes the water speed very high over its entire section, making mineral deposits of any kind negligible. The typical omega shape of the finning ensures an even distribution of the heat over all the finning, with consequent benefits in terms of exchange efficiency and the life of the exchanger. A special surface treatment protects the exchanger against oxidation and corrosion.
Version - 09.2002
13
Page 14
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
Hydraulic unit
This is a single piece of brass to which the exchanger delivery is connected for ease of access. It accommodates a number of safety and adjustment components.
The hydraulic unit includes:
- safety valve
- water pressure switch
- heating sensor
- filler cock
- tap water sensor
- tap water check valve
Water pressure switch
It ensures a minimum pressure for the system. It is normally open (NO) and closes the contact when the pressure exceeds 0.5 bar. It works on low voltage.
Safety valve
It opens if the pressure exceeds 3 bars, making boiler operation safer and protecting it against overpressure. You are strongly recommended not to use this valve to drain the system; once open, dirt could remain inside it, preventing it from closing completely.
Check valve
This is necessary to ensure no water returns from the heating system to the tap water circuit.
Filler cock
This is located between the heating delivery and the tap water outlet. It is not fitted on the boiler for some markets such as the British and Belgian ones.
14
Version - 09.2002
Page 15
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
2.2 Hydraulic circuit  tap water
Hydraulic diagram for tap water
Key
5 Airtight chamber 7 Gas inlet 8 Tap water outlet
9 Tap water inlet 10 System delivery 11 System return 14 Safety valve 16 Fan 20 Burner unit 27 Heat exchanger 29 Fume outlet collar 32 Heating circulator 34 Heating temperature sensor 42 Tap water temperature
sensor
43 Air pressure switch 44 Gas valve 49 Safety thermostat 50 Heating thermostat 56 Expansion tank 74 Heating system cock 81 Ignition electrode 82 Detection electrode
114 Water pressure switch 136 Flow meter 187 Fume diaphragm
When the card receives a signal from the flow meter indicating a tap-water draw of over 2.5 l/min, the boiler starts working normally for tap water. If heating was in operation, or the pump was anyhow working, the boiler will in any case give priority to the tap water, stopping the pump. The tap water does not exchange directly with the products of combustion, but via the heating water in the exchanger, avoiding sudden changes in temperature.
Version - 09.2002
15
Page 16
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
Flow meter
Located at the cold water inlet, its task is to provide the card with a signal at a frequency (7 Hz per litre) in direct proportion to the tap-water flow rate. It is composed of a body (stator) and a rotor inside it. There is a filter on its inlet to prevent foreign bodies damaging it. It should be remembered that to turn on the boiler for tap-water operation, the tap-water pressure must be at least 0.25 bars and the draw flow rate must be greater than 2.5 l/min.
Check
To check it works properly, you need to make sure the flow rate is at least
2.5 l/min and then test the signal to the electric card with a frequency meter. This makes it possible to understand whether the problem lies with the flow meter, incorrect contacts, or the card.
Flow-rate restrictor
This is a diaphragm downstream from the flow meter. Its task is to limit the tap­water flow rate; the boiler modulates its capacity to keep the tap-water temperature set by the user, but since the boiler capacity is limited to its rated capacity, it is necessary to limit the tap-water flow rate to obtain high T.
16
In this case, above the flow­rate limit m, even though the boiler is working at its rated capacity, it is not able to maintain the set tempe­rature of 50°C.
Version - 09.2002
*
Page 17
Supplied By www.heating spares.co Tel. 0161 620 6677
2.3 Gas circuit
Gas circuit diagram
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
Key
5 Airtight chamber 7 Gas inlet 8 Tap water outlet
9 Tap water inlet 10 System delivery 11 System return 14 Safety valve 16 Fan 20 Burner unit 27 Heat exchanger 29 Fume outlet collar 32 Heating circulator 34 Heating temperature
sensor
42 Tap water temperature
sensor
43 Air pressure switch 44 Gas valve 49 Safety thermostat 50 Heating thermostat 56 Expansion tank 74 Heating system cock 81 Ignition electrode 82 Detection electrode
114 Water pressure switch 136 Flow meter 187 Fume diaphragm
Version - 09.2002
17
Page 18
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
Gas valve
It supplies gas to the nozzles between a minimum and maximum pressure. For the valve to work correctly, it is necessary for the pressure upstream from it to be stable and suited to the type of gas being used, while the valve will supply a regular pressure to the nozzles. The gas valve contains two operators. The function of the first one is to open or close, while the task of the second one is to modulate the capacity according to the system's requirements. The signal comes from the card (X6-1/2/3/4) and is in the form of continuous voltage. The first operator receives fixed voltage that may be between 80 and 110V DC, for the second operator the voltage will vary between 25 and 54V DC according to the need of the main card.
Checks
If the valve doesn't work:  Check there is gas, and that gas comes out of the valve by means of
screw B.
If there is no gas, you must check there is voltage at the operators. This
makes it possible to understand whether the problem lies with the valve (there is voltage at the operators) or with the card (there is no voltage at the contacts X6-1/2/3/4).
Modulation
The control system governs its boiler capacity so as to keep the delivery temperature constant in accordance with the settings on the control panel. The nozzle gas pressure is modulated by the valve and specifically via the 2nd operator. The card provides a change in continuous voltage (between 25 and 54 V DC) according to the difference between the delivery temperature and the set point.
Checks
Modulation can be checked in three ways:  Visually, by checking the flame.  Using a pressure gauge to check the gas pressure downstream from the valve.  Checking the voltage of the second operator on the card (X6, 1/2). This is the most effective method
in some situations. With this test, it is possible to understand whether the problem lies with the valve or with the card.
Note that with very low pressure upstream from the valve, opening the valve may be slow and the boiler could shut down due to failed ignition.
18
Version - 09.2002
Page 19
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
Adjusting burner pressure
Since this unit has flame modulation, there are two fixed pressure settings: the minimum and maximum, which must be as stated in the technical data chart according to the type of gas.
Connect a suitable pressure gauge to pressure point "B"
downstream from the gas valve.  Disconnect the pressure compensation tube "F".  Take off the protective cap C.  Set the potentiometer P3 (on the control card) to minimum
(clockwise).  Run the boiler in heating mode.  Adjust the minimum pressure with the screw D, clockwise
to decrease it and anticlockwise to increase it.  Set the potentiometer P3 to maximum (anticlockwise).  Turn on the TEST function by temporarily bridging X5.  Adjust the maximum pressure with the screw E, clockwise
to increase it and anticlockwise to decrease it.  Reconnect the pressure compensation tube F.  Put the protection screw C back in.  Disconnect the test jumper.
N.B. The test lasts 5 minutes. It is advisable to open 1 or 2 taps
to get rid of the excess capacity.
After checking or
adjusting the pres­sure, it is mandatory to seal the adjustment screw with paint or a specific seal.
Key
A Pressure point upstream
B Pressure point downstream C Protection screw D Minimum pressure adjustment
screw
E Maximum pressure adjustment
screw
F Pressure compensation tube
Version - 09.2002
19
Page 20
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
Gas supply conversion
The unit can function with either Natural Gas or LPG and is factory-set for use with one of the two gases, as clearly shown on the packing and on the unit's dataplate. Whenever a different gas to that for which the unit is preset has to be used, a conversion kit will be required, proceeding as follows:
1 Replace the nozzles at the main burner,
inserting the nozzles specified in the technical data table, according to the type of gas used.
2 Adjust the burner minimum and maximum
pressres, setting the values given in the technical data chart for the type of gas used.
3 Move the jumper JP02 on the card, as
shown in the diagram:
Natural gas operation
LPG operation
4 Apply the sticker, contained in the
conversion kit, near the dataplate as proof of the conversion.
20
Version - 09.2002
Page 21
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
2.4 Burner unit
Operation
The burner unit comprises a manifold and 12/16 nozzles (depending on the capacity), the burner mount, electrodes and the burner assembly.
Manifold - nozzles
The valve sends gas at a suitable pressure to the manifold, which homogeneously distributes the gas to the single burner stages at the nozzles. It is secured directly to the burner mount. Its positioning must be exact since it affects the air/gas mixture. In addition, the threaded holes forming the seat of the nozzles must be aligned with the respective Venturi tube of the burner. If it were not so, the air/gas mixture would be wrong and there would be poor combustion with an unstable flame. The nozzles are made of brass and machined extremely precisely for their dimensions. There is a seal between the nozzles and the manifold.
Ignition electrode
The ignition electrode is made of a metal alloy (Kanthal) that withstands high temperatures and oxidation. Its base is composed of a ceramic composite of glazed alumina whose purpose is to protect and electrically insulate it. Once the ignition procedure begins, the card powers the electrode with a pulsating voltage of a few kV, a series of electrical discharges is set off between the electrode and the head of the burner (set at a distance of 3.5 mm). Clearly, these sparks are the trigger for the air-gas mixture. It is important for the distance between the electrode and the burner head to be 3 - 4 mm and the discharge to be made at the centre.
Checks
If there is no discharge:  Check whether the boiler shuts down, in which case check
the connection of the electrode to the card or whether it discharges at other points; if necessary, check the safety thermostat and the card.
If the boiler does not shut down and the fan keeps on
working, check the air pressure switch.
If there is a discharge, but no ignition and after 10 seconds
the boiler shuts down, check the gas valve and, if necessary, the card.
If there is a discharge and then a flame, but the boiler still
shuts down after 10 seconds, check the detection electrode and its connection.
Version - 09.2002
21
Page 22
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
Detection electrode
Made of the same material as the ignition electrode, it is set 11 mm from the burner head. Combustion causes the flame atmosphere to ionize, making it conductive. Thanks to the mass of the burner, making a suitable potential with the electrode produces a flow of direct current on it. For our cards, it is necessary to have an ionizing current of at least
0.5 µA to detect a flame. A mean signal is normally obtained of approximately 2 µA.
Burner assembly
The burner assembly is composed of 12 or 16 burner stages. Each stage is composed of two pressed steel half bearings, with a suitably cut stainless steel head. Gas enters at the bottom of the stage. Thanks to the special Venturi-tube shape of the bottom portion of the stage, the gas "injected" by the nozzle carries with it the primary air needed for combustion. The air-gas mixture thus formed inside the stage is evenly distributed on the burner head. Combustion takes place homogeneously over the entire length of the single stages, with the contribution of the secondary air from the bottom of the burner mount and from the combustion chamber itself. The set of stages in operation forms a single belt of flame, light blue in colour, whose size varies according to the nozzle gas pressure, that is the boiler capacity modulation.
22
Version - 09.2002
Page 23
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
2.5 Fume circuit
Fume deflector and manifold
All forced-flow boilers have a fume deflector above the exchanger whose main task is to make the secondary air crossing the burners uniform, making the flame homogeneous and stable. The fumes then reach a fume manifold whose job is to make them move on to the fan.
Airtight chamber
Its task is to isolate the products of combustion from the area surrounding the boiler. The airtight chamber contains all the components involved in the fume routing. The wires and pipes coming out of its lower portion are insulated with silicone seals, while its upper portion is fitted for hooking up with the flues. The cover is sealed off with a porous plate and is fitted with two plugs for using a probe to analyse the fumes and combustion air.
Fan and pressure switch points
Powered at 230V/50Hz by the card (X6 - 7/8), the fan has the job of expelling the products of combustion from the fume chamber. A plate is normally placed above the exchanger to act as a deflector, make the incoming air from the bottom of the burner uniform, make the flame stable and obtain the required air/gas ratio. In order to make sure the fan works properly, there are two pressure points inside it. The first one detects a static pressure signal that is positive, the second one detects a dynamic pressure signal via an appropriate Venturi tube, which is negative. With the difference in pressure detected by the two test points it is possible to check whether the fumes are adequately evacuated.
Version - 09.2002
23
Page 24
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
Air pressure switch
This is used to check whether the fumes are adequately evacuated. The pressure switch compares the static and dynamic signals coming from the pressure test points on the fan according to the figure. The pressure switch is connected to the card and is normally open (see diagram). Before the card initiates the ignition procedure (opening the valve, etc.), you must make sure that the fan works properly and that the air pressure switch ensures this by closing its contacts. This happens if the difference in pressure is 165±15Pa. So the signal must be at least 180Pa. To open its contacts again, the difference in pressure must drop under 150±13Pa. To perform checks on contact opening and closing, it is always recommended to check directly on the card (X5 - 3/4).
Checks
It is necessary to check:  Whether the electrical connections are correct.  Whether the pressure test point pipes are clean and contain no condensation water.  That the signal is open when the fan is not working.  That the pressure is at least 180Pa and that above this pressure the pressure switch closes its
contacts.
If the signal is low, it is necessary to check that the fume diaphragm is correct, the fan has 230V, the
pressure test points are properly inserted and the Venturi tube has no burrs of any kind. Lastly, check that the ends of the pipes are not obstructed.
N.B. The pressure difference must be measured with the airtight chamber closed. The pressure gauge connections can come out through the hole, which is closed by a silicone plug, on the front of the cover.
Key
NO = Normally open NC = Closed C = Common
24
Version - 09.2002
Page 25
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
Fume ducts
The unit is type C with an airtight chamber and forced draught, the air inlet and fume outlet must be connected to one of the following extraction/suction systems. With the aid of the tables and methods of calculation indicated, before commencing installation, it is first necessary to check that the fume ducts do not exceed the maximum permissible lengths. The current standards and local regulations must be observed.
This C-type unit must be installed using the fume exhaust and suction ducts supplied by FERROLI S.p.A. in accordance with UNI-CIG 7129/92. Failure to use them automatically forfeits all warranty and liability of FERROLI S.p.A.
Diaphragms
Boiler operation requires fitting the diaphragms supplied with the unit as instructed in the following tables. As the resistance of the fume ducts changes, the diaphragms make it possible to keep the combustion parameters (CO2, etc.) within the optimum operating range. Note that with low-resistance fume ducts, a high-resistance diaphragm (small hole diameter) is used and vice versa.
Choosing the diaphragm using coaxial pipes
Changing the diaphragm
If inserting or changing a diaphragm, it is necessary to remove the fan assembly, take out the fume coupling 1 and insert the required diaphragm 2.
Choosing the diaphragm using sepa­rate pipes
.
1
Boilers are fitted as standard with the smallest diaphragm in the series. Before inserting the fume outlet pipe, it is therefore necessary to check there is the right diaphragm (when it is to be used) and that it is correctly positioned.
Version - 09.2002
.
2
25
Page 26
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
Calculation example
Here we give an example of the calculation for a separate fume outlet. We recommend inserting a condensate trap on long vertical sections to prevent condensation getting onto the burner and damaging it. If monitoring the con­densate trap is not guaranteed, it must be fitted with a suitable drain pipe and air trap, which in its turn must be appropriately connected to a suitable drain.
26
Version - 09.2002
Page 27
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
2.6 Electrical circuit
Electrical terminal board
Follow the instructions given in the figure to access the electrical connection terminal board. The layout of the terminals for the various connections is given in the wiring diagram.
Wiring diagram
Key
16 Fan 32 Heating circulator 34 Heating temperature sensor 42 Tap water temperature sensor 43 Air pressure switch 49 Safety thermostat 50 Heating thermostat
N.B. Respect the phase and neutral connections
Version - 09.2002
72 Room thermostat (not supplied) 73 Antifreeze thermostat 81 Ignition electrode
82 Detection electrode 114 Water pressure switch 136 Flow meter
27
Page 28
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
Main electronic card
The electronic card is a Honeywell MF03: part of the card works on low voltage (24V) and the remainder on 230V (see diagram) and it is fitted with a fuse (2A). Part of the card is used to control ignition, so it is hooked up to the detection and ignition electrodes and the safety thermostat. There are loads and controls common to the card that have already been described, such as:
Pump.  Fan.  Gas valve.  Air pressure switch. There remain some components described hereunder.
Ignition + detection electrode, see chap. 2.4 Burner Unit
Safety thermostat
X6 - 5/6 has a thermostat with gold contacts that opens if the temperature exceeds 100°C. Connected directly to the ignition and main card, when it opens it cuts off the power supply to the valve directly, shutting down the boiler. It is set on the left-hand side of the exchanger by a spring.
Limit thermostat
Connected on the main card X4 - 6/7, it is a thermostat with silver contacts that opens if the temperature exceeds 88°C. It requires no manual resetting and closes the contacts again if the temperature falls under 70°C. It is set on the right-hand side of the exchanger by a spring.
28
Version - 09.2002
Page 29
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
Heating and tap water temperature probe
These are NTC sensors that increase their resistance as the temperature decreases and are connected directly to the main card X4 - 24V (heating 12­13, tap water 10-11). The heating sensor performs the antifreeze function too.
Version - 09.2002
29
Page 30
Supplied By www.heating spares.co Tel. 0161 620 6677
3. OPERATION
3.1 Operating principle
When there is a call for heating, the circulator and fan start working; then the air pressure switch enables the control and safety unit to ignite the burner. Via the electronic flame modulation system, the boiler capacity is gradually metered till it reaches the set delivery temperature. If the power needed for the heating plant is lower than the minimum boiler power, when the delivery temperature exceeds the setting of 6°C, the burner switches off and the electronic system enables re-ignition only after another 2 minutes. On reaching the set ambient temperature (room thermostat), the burner switches off and the circulator keeps on working for another 6 minutes to enable better heat distribution throughout the system. If hot tap water is drawn off during the heating phase, the electrical heating circuit automatically turns off and the hot tap water production circuit switches on. Throughout this phase the heating system circulator stops and the boiler delivers water at the set temperature.
The boiler keeps the tap water temperature constant by means of flame modulation, even when different quantities are drawn off.
Test function
Bridging the terminals of connector X5 turns on Test operation. In this mode the boiler works as in heating mode, but tap water operation, idle time and modulation are turned off. The test lasts 5 minutes. We recommend opening 1 or 2 taps to get rid of the excess capacity.
Post-circulation
After the call for heating, the circulator performs "post-circulation" for approximately 6 minutes to prevent thermal inertia and balance the system boiler temperature.
Circulator anti-locking
If not used for 24 h, the circulator is turned on for a few seconds to prevent it locking due to an extended stoppage during summertime operation.
Gradual starting on heating (gradual increase in heating temperature)
The time to reach the maximum heating temperature is 5 minutes.
Limit thermostat
The 88°C limit thermostat coming on causes the burner to switch off momentarily via the ignition unit and the heating circulator to start up.
Antifreeze protection
The antifreeze function is turned on by the heating temperature sensor when the temperature falls under 5°C. In this phase, both the burner and the circulator start working. When the temperature reaches 15°C, the burner switches off while the circulator keeps on working for another 6 minutes.
Tap water circuit antifreeze protection (optional)
It is possible to ensure antifreeze protection for the tap water circuit with the antifreeze kit comprising 4 heating elements of 10W - 230V to be connected to terminal X2 of the control card.
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
30
Version - 09.2002
Page 31
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
3.2 Operating diagram
Version - 09.2002
31
Page 32
Supplied By www.heating spares.co Tel. 0161 620 6677
3.3 Control panel
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
3.4 Adjustments
Room temperature adjustment (with room thermostat on)
Using the room thermostat or remote control, set the temperature desired in the rooms. Controlled by the room thermostat, the boiler lights and heats the system water to the set system delivery setpoint temperature. The generator turns off when the desired temperature in the rooms is reached.
If the room thermostat or the remote control are not installed the boiler will keep the system at the set system delivery setpoint temperature.
System temperature adjustment
With knob B on the control panel we can set the required system temperature. To prevent localized condensation on the fume circuit, we recommend a minimum temperature of 60°C.
Hot water temperature adjustment
With knob C on the control panel we can set the tap water temperature from 40°C to 55°C (62°C on inserting jumper JP03).
Summer/Winter selection
Setting the adjustment potentiometer B to minimum (), the boiler works on Summer.
Adjusting the heating t by changing the circulator delivery-head
The temperature difference t (difference between the system delivery and return heating water temperatures) must be under 20°C and is obtained by changing the circulator delivery-head with its variable speed device (or switch).
32
Version - 09.2002
Page 33
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
3.5 Operating parameter adjustment
Boiler parameter adjustment
P1 Temperature adjustment potentiometer.
Controls the heating delivery temperature from 30°C to 85°C. The minimum position selects Summer operation.
P2 Hot tap water adjustment potentiometer.
Controls the hot tap water temperature from 40°C to 55°C.
P3 Heating capacity adjustment potentiometer.
P4 Potentiometer to adjust the burner gas pressure in the ignition phase.
The maximum ignition time is 10 sec. The ignition curve should be regulated taking account of the type of burner and fuel used
(natural gas or LPG).
P5 Minimum pressure adjustment potentiometer.
The potentiometer P5 is to be used if it is necessary to adjust the minimum current to the second coil of the gas valve.
This adjustment makes it possible to increase the gas valve minimum opening pressure electrically. The potentiometer P5 is used when the mechanical minimum of the gas valve does not enable adequate adjustment.
Jumper operation
Version - 09.2002
33
Page 34
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
4. Troubleshooting
Flow Diagram 1
Checking Electric Power Supply - System Pressure and Antifreeze Protection
34
Version - 09.2002
Page 35
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
Flow Diagram 2
Checking Hot Water Operation
Flow Diagram 3
Checking Heating Operation
Version - 09.2002
35
Page 36
Supplied By www.heating spares.co Tel. 0161 620 6677
Flow Diagram 4
Checking Fan/Fume Circuit
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
36
Version - 09.2002
Page 37
Supplied By www.heating spares.co Tel. 0161 620 6677
Flow Diagram 5
Checking Ignition
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
Flow Diagram 6
Check the Modulation of the Hot Water and Heating
Version - 09.2002
37
Page 38
Supplied By www.heating spares.co Tel. 0161 620 6677
Page 39
Supplied By www.heating spares.co Tel. 0161 620 6677
Page 40
Supplied By www.heating spares.co Tel. 0161 620 6677
37047 SAN BONIFACIO - VR - ITALY tel. 045/6139411 - tlx 480172 fax 045/6100233-6100933
cod. 354M002/0
Loading...