Our appliance is a high-efficiency heat generator for central heating running on natural gas or LPG
(configurable at the time of installation).
The boiler shell consists of a copper laminar exchanger whose particular shape guarantees high
exchange efficiency under all operating conditions and an open-flue burner equipped with electronic
ignition and ionization flame control.
The boiler is totally sealed off from the installation room: the air needed for combustion is drawn from
outside and the flue gases are expelled by a fan. The boiler outfit moreover includes a variable speed
circulator, expansion tank, safety valve, filler cock, air pressure switch, water pressure switch,
temperature sensor and a safety thermostat.
Thanks to the control and adjustment system, unit operation is for the most part automatic. The power
for heating is automatically governed by the control system according to the indoor characteristics, the
characteristics of the building and of its location.
There are 5 LEDs on the control panel providing information on the units operating status.
General Warnings
Installation and maintenance must be carried out by professionally qualified personnel, according
to current regulations and the manufacturers instructions.
Incorrect installation or poor maintenance can cause damage or physical injury. The manufacturer
declines any responsibility for damage caused by errors in installation and use or by failure to
follow the manufacturers instructions given in the instructions manual..
Before carrying out any cleaning or maintenance operation, disconnect the unit from the electrical
power supply using the switch and/or the special cut-off devices.
Certification
The CE marking demonstrates that Ferroli gas units conform to the requirements contained in the
applicable European directives.
In particular, this unit complies with the following EU directives:
Gas Appliance Directive 90/396 assimilated with Italian Presidential Decree DPR 15.11.96 no.
661
Efficiency Directive 92/42 assimilated with Italian Presidential Decree DPR 15.11.96 no. 660
Low Voltage Directive 73/23 (amended by 93/68)
Electromagnetic Compatibility Directive 89/336 (amended by 93/68) assimilated with Italian
Presidential Decree DPR 15.11.96 no. 615
Version - 09.2002
3
DOMITOP HF 24 - 30 E
Supplied by HeatingSpares247.com
FERELLA GOLD HF 24 - 30 MEL
1.2 Dimensions and connections
Domitop HF 24 E version
49Safety thermostat
50Heating thermostat
56Expansion tank
63Heating temperature adjustment
74Heating system cock
81Ignition electrode
36
82Detection electrode
841st gas valve operator
32
852nd gas valve operator
98Off-On-Reset switch
114 Water pressure switch
145 Water gauge
187 Fume diaphragm
10
74
14784114485
ON
RESET
OFF
°C
9863145
bar
3
4
2
1
5
0
6
DOMITOP - FERELLA GOLD version
Version - 09.2002
9
FERELLA GOLD HF 24 - 30 MEL
Supplied by HeatingSpares247.com
1.4 Technical data table
DOMITOP HF 24 - 30 E
DOMITOP - FERELLA GOLD
PowersPmaxPmin
Heating Power (Net Heat Value - Hi)
Heating Power (Gross Heat Value - Hi)
Useful heating power 80°C - 60°C
Gas supplyPmaxPmin
Natural Gas main nozzles (G20)mm12 x 1.30
Natural Gas supply pressure (G20)mbar20.0
Pressure at Natural Gas burner (G20)mbar11.82.5
Natural Gas delivery (G20)nm
LPG main nozzles (G31)mm12 x 0.77
LPG supply pressure (G31)mbar37.0
Pressure at LPG burner (G31)mbar36.07.0
LPG burner (G31)Kg/h2.000.87
Heating
Maximum working temperature in heating°C90
Maximum working pressure in heatingbar3
Safety valvebar3
Minimum working pressure in heatingbar0.8
Expansion tank capacitylitres8
Expansion tank pre-filling pressurebar1
Boiler water contentlitres1.5
Dimensions, weights connections
Heightmm760
Widthmm460
Depthmm272
Weight with packingkg35
Gas system connectioninches1/2
Filling system connection1/2
Heating system connection3/4
Electrical power supply
Max electrical power absorbedW125
Power voltage/frequencyV/Hz220/50
Electrical protection ratingIP44
kW25.811.2
kcal/h22,2009,900
kW28.712.4
kcal/h24,70010,700
kW23.39.7
kcal/h20,0008,300
3
/h2.731.19
inches
inches
24 KW
30 KW
PmaxPmin
33.114.5
28,50012,500
36.816.1
31,60013,800
30.012.7
25,80010,900
PmaxPmin
16 x 1.25
20.0
11.82.5
3.501.53
16 x 0.75
37.0
35.57.0
2.571.13
90
3
3
0.8
10
1
1.7
760
460
363
45
1/2
1/2
3/4
125
220/50
44
10
Version - 09.2002
DOMITOP HF 24 - 30 E
Supplied by HeatingSpares247.com
FERELLA GOLD HF 24 - 30 MEL
2. PRODUCT FRAMEWORK AND INTERNAL
COMPONENTS
2.1 Hydraulic circuit heating
Hydraulic diagram for heating
When there is a call for heat, the room thermostat or control system make the burners ignite and the
circulation pump come into operation. The heat contained in the products of combustion is transferred to the
water by the system via the exchanger. For more details on the operating logic, refer to chap.3.
114 Water pressure switch
187 Fume diaphragm
222 Copper exchanger
34
114
14
74
10
Version - 09.2002
7
11
32
11
DOMITOP HF 24 - 30 E
Supplied by HeatingSpares247.com
FERELLA GOLD HF 24 - 30 MEL
Circulator (230v/50Hz)
Located on the heating circuit return, it is connected directly to the exchanger
via special forks and connected to the system via a threaded brass section. It
has three delivery/head levels (see diagram). Changing the delivery/head
changes the speed of the water flowing through the boiler exchanger and as
a result the temperature difference ( T) between heating delivery and return.
Clearly, increasing the delivery of the circulator decreases T and vice versa.
If it is not used for a long time, the impeller might jam due to debris in the water.
With the front screw it is possible to access the impeller, which can be freed with
the aid of a screwdriver. The connection to the expansion tank and the air
separator is installed on the pump casing.
Checks
If the pump doesnt work:
Check that the impeller is free to turn by turning the screw on the front with
a screwdriver.
Check that both the card and the pump connection are powered.
If there is no power supply, check the card.
If there is power, change the pump.
Key
1 - 2 - 3 = Pump selector position
A = Losses of head 24kW version
m
C.A.
6
5,5
5
4,5
4
3,5
3
2,5
2
1,5
1
0,5
0
3
2
1
0,60,11,1,1,1,22,2,2,6
B = Losses of head 30kW version
A
B
2,833,23,43,63,840,40,20
Air separator
This is used to expel the air in the heating circuit automatically and is located
on the pump casing. It is normally accessible either via the fork or by simply
unscrewing it from its seat.
m3/h
12